Simultaneous in vivo positron emission tomography and magnetic resonance imaging

被引:197
|
作者
Catana, Ciprian [1 ]
Procissi, Daniel [2 ]
Wu, Yibao [1 ]
Judenhofer, Martin S. [3 ]
Qi, Jinyi [1 ]
Pichler, Bernd J. [3 ]
Jacobs, Russell E. [2 ]
Cherry, Simon R. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Genome & Biomed Sci Facil, Davis, CA 95616 USA
[2] CALTECH, Beckman Inst, Pasadena, CA 91125 USA
[3] Univ Tubingen, Lab Preclin Imaging & Imaging Technol, Dept Radiol, D-72076 Tubingen, Germany
关键词
molecular imaging; small animal imaging; multimodality imaging;
D O I
10.1073/pnas.0711622105
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner.
引用
收藏
页码:3705 / 3710
页数:6
相关论文
共 50 条
  • [11] Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging
    Ripa, Rasmus Sejersten
    Kjaer, Andreas
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [12] Positron emission tomography and magnetic resonance imaging in heart failure
    Bengel, FM
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (02) : 145 - 149
  • [13] Positron emission tomography/magnetic resonance imaging in ventricular arrhythmia
    Lin, Chin-Yu
    Lin, Yenn-Jiang
    Huang, Wen-Sheng
    EUROPACE, 2020, 22 (08): : 1269 - 1269
  • [14] Clinical Positron Emission Tomography/Magnetic Resonance Imaging Applications
    von Schulthess, Gustav K.
    Kuhn, Felix Pierre
    Kaufmann, Philipp
    Veit-Haibach, Patrick
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 3 - 10
  • [15] Positron emission tomography and magnetic resonance imaging in heart failure
    Bengel F.M.
    Journal of Nuclear Cardiology, 2006, 13 (2) : 145 - 149
  • [16] Management and Organization of Positron Emission Tomography/Magnetic Resonance Imaging
    Devlin, Patricia
    Sher, Andrew
    Rubbert, Christian
    Jordan, David
    Faulhaber, Peter
    Avril, Norbert
    Ros, Pablo
    SEMINARS IN ROENTGENOLOGY, 2014, 49 (03) : 271 - 274
  • [17] Positron Emission Tomography/Magnetic Resonance Imaging of Gastrointestinal Cancers
    Goh, Vicky
    Prezzi, Davide
    Mallia, Andrew
    Bashir, Usman
    Stirling, J. James
    John, Joemon
    Charles-Edwards, Geoff
    MacKewn, Jane
    Cook, Gary
    SEMINARS IN ULTRASOUND CT AND MRI, 2016, 37 (04) : 352 - 357
  • [18] Behavioral neuroimaging with positron emission tomography and magnetic resonance imaging
    Schneider, F
    Grodd, W
    Machulla, HJ
    NERVENARZT, 1996, 67 (09): : 721 - 729
  • [19] Simultaneous fluorescence and positron emission tomography for in vivo imaging of small animals
    Zhang, Bin
    Liu, Shuangquan
    Liu, Fei
    Zhang, Xiaochun
    Xu, Yanyan
    Luo, Jianwen
    Shan, Baoci
    Bai, Jing
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (12)
  • [20] Comparison of in vivo magnetic resonance and positron emission tomography imaging in patients with abdominal aortic aneurysms
    Joshi, N. V.
    Elkhawad, M.
    Alam, S. R.
    Richardson, H.
    Semple, S.
    Macgillivray, T.
    Van Beek, E. J. R.
    Richards, J. M. J.
    Rudd, J.
    Newby, D. E.
    EUROPEAN HEART JOURNAL, 2012, 33 : 258 - 258