Dicationic-Type Quaternary Ammonium Salts as Candidates of Desiccants for an Air-Conditioning System

被引:7
|
作者
Itoh, Toshiyuki [5 ]
Hiramatsu, Mariko [1 ]
Kamada, Kentaro [1 ]
Nokami, Toshiki [1 ]
Nakayama, Hiroshi [2 ]
Yagi, Kenichi [3 ]
Yan, Fangyong [4 ]
Kim, Hyung J. [4 ]
机构
[1] Tottori Univ, Dept Chem & Biotechnol, Grad Sch Engn, Tottori 6808552, Japan
[2] Chubu Elect Power Co Inc, Res & Dev Div, Adv Res & Innovat Ctr, Nagoya, Aichi 4598522, Japan
[3] Toyota Cent Res & Dev Labs Inc, Nagakute, Aichi 4801192, Japan
[4] Carnegie Mellon Univ, Dept Chem, Pittsburgh, PA 15213 USA
[5] Toyota Phys & Chem Res Inst, Nagakute, Aichi 4801192, Japan
来源
ACS SUSTAINABLE CHEMISTRY & ENGINEERING | 2021年 / 9卷 / 43期
关键词
quaternary ammonium salt; dication; desiccant; air conditioner; reducing energy; VAPOR-PRESSURE MEASUREMENT; HYDROPHILIC IONIC LIQUIDS; THERMODYNAMIC PROPERTIES; BINARY-MIXTURES; 1-ETHYL-3-METHYLIMIDAZOLIUM ACETATE; CHOLINE LACTATE; PLUS WATER; DEHUMIDIFICATION; ENERGY; EQUILIBRIUM;
D O I
10.1021/acssuschemeng.1c04971
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Liquid desiccant air conditioners contribute to sustainable living by reducing the electricity consumption. They can be driven with continuous ventilation and thus can prevent airborne transmission of infectious diseases like COVID-19. In order to develop efficient desiccant materials for liquid desiccant air conditioners, we have investigated the dehumidification capability of 21 types of ammonium salts, many of them being ionic liquids. The hygroscopicity of dicationic quaternary ammonium bis(dimethyl or diethylphosphate) is found to increase with the carbon chain length of the spacer group -(CH2)(n)- that bridges the two terminal cationic moieties of the dication, that is, (CH2)(2) < (CH2)(3) < (CH2)(6). This trend remains unchanged when methyl substituents on the cation and the phosphate anion are replaced by ethyl groups. A high dehumidification capability is obtained for N-1,N-1,N-1,N-6,N-6,N-6-hexamethylhexane-1,6-diaminium bis(dimethylphosphate) ([HMC6]-[DMPO4](2)) and 1,6-diethyl-1,1,6,6-tetramethylhexane-1,6-diaminium bis( diethylphosphate) ([DETMC6][DEPO4](2)); their capability per gram reaches almost twice that of CaCl2, and their dehumidification rate is superior to popular solid desiccants. A favorable equilibrium water vapor pressure for the liquid desiccant air-conditioning system is attained for an 80% (w/w) aqueous solution of [HMC6][DMPO4](2). In addition, the 80% aqueous solution of [HMC6][DMPO4](2) affords no corrosive effect on steel, aluminum, and stainless steel and a very weak effect on copper. Dicationic quaternary ammonium bis(dimethyl or diethylphosphate)s are stable compounds; their aqueous solutions produce no odor after storing for over 1 year under ambient conditions. Molecular dynamics simulations are performed to gain insights into the solvation structure, energetics, and transport behavior of water in aqueous solutions of [HMC6][DMPO4](2) and related salts.
引用
收藏
页码:14502 / 14514
页数:13
相关论文
共 50 条
  • [31] Conventional and advanced exergy analyses of an air-conditioning system in a subway station
    Yin, Hua
    Guo, Huafang
    Tang, Zhihua
    Yu, Junyan
    Lu, Haiyang
    INTERNATIONAL JOURNAL OF EXERGY, 2019, 29 (2-4) : 236 - 262
  • [32] Space temperature control of a GSHP-integrated air-conditioning system
    Gao, Jiajia
    Huang, Gongsheng
    Xu, Xinhua
    ENERGY AND BUILDINGS, 2015, 108 : 127 - 136
  • [33] Mass transfer research on the regeneration process of an air-conditioning battery system
    Guo, Yuting
    Yuan, Ling
    Cheng, Feng
    Li, Xiuwei
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [34] Dynamic characteristics of a R-410A split air-conditioning system
    Kim, MH
    Bullard, CW
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07): : 652 - 659
  • [35] Investigation of a compact hybrid liquid-desiccant air-conditioning system for return air dehumidification
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    BUILDING AND ENVIRONMENT, 2021, 187
  • [36] Research on ration selection of mixed absorbent solution for membrane air-conditioning system
    Li, Xiu-Wei
    Zhang, Xiao-Song
    Wang, Fang
    Zhao, Xiao
    Zhang, Zhuo
    ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 111 - 119
  • [37] Experimental investigation of an automotive air-conditioning system driven by a small biogas engine
    Damrongsak, Det
    Tippayawong, Nakorn
    APPLIED THERMAL ENGINEERING, 2010, 30 (05) : 400 - 405
  • [38] Factor analysis and optimization of operational parameters in a liquid desiccant air-conditioning system
    Tu, Min
    Huang, Hui
    Liu, Ze-Hua
    Chen, Huan-Xin
    Ren, Cheng-Qin
    Chen, Guo-Jie
    Hu, Yan
    ENERGY, 2017, 139 : 767 - 781
  • [39] Low GWP Fluids for Replacing R134a in an Air-Conditioning System
    Li, Houpei
    Peng, Jinqing
    6TH IIR CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR2021), 2021, : 350 - 357
  • [40] Study on the marine ejector refrigeration-rotary desiccant air-conditioning system
    Zheng, C. Y.
    Zheng, G. J.
    Yu, W. S.
    Chen, W.
    2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, ENERGY TECHNOLOGY AND ENVIRONMENTAL ENGINEERING (MSETEE 2017), 2017, 81