Continuous-wave near-infrared spectroscopy is not related to brain tissue oxygen tension

被引:11
作者
Kerz, Thomas [1 ]
Beyer, Christian [1 ]
Huthmann, Alexandra [3 ]
Kalasauskas, Darius [1 ]
Amr, Amr Nimer [1 ]
Boor, Stephan [2 ]
Welschehold, Stefan [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Neurosurg, Langenbeckstr 1, D-55131 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Neuroradiol, Univ Med Ctr, Mainz, Germany
[3] Ludmillenstift, Meppen, Germany
关键词
Near-infrared spectroscopy; Brain oxygen tension; Brain trauma; Subarachnoid haemorrhage; Brain death; CEREBRAL-BLOOD-FLOW; VENOUS OXIMETRY; SATURATION; VALIDATION; MONITOR;
D O I
10.1007/s10877-015-9755-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Near-infrared spectroscopy (NIRS) has gained acceptance for cerebral monitoring, especially during cardiac surgery, though there are few data showing its validity. We therefore aimed to correlate invasive brain tissue oxygen measurements (PtiO2) with the corresponding NIRS-values (regional oxygen saturation, rSO2). We also studied whether NIRS was able to detect ischemic events, defined as a PtiO2-value of < 15 mmHg. Eleven patients were studied with invasive brain tissue oxygen monitoring and continuous-wave NIRS. PtiO2-correlation with corresponding NIRS-values was calculated. We found no correlation between PtiO2- and NIRS-readings. Measurement of rSO2 was no better than flipping a coin in the detection of cerebral ischemia when a commonly agreed ischemic PtiO2 cut-off value of < 15 mmHg was chosen. Continuous-wave-NIRS was unable to reliably detect ischemic cerebral episodes, defined as a PtiO2 value < 15 mmHg. Displayed NIRS-values did not correlate with invasively measured PtiO2-values. CW-NIRS should not be used for the detection of cerebral ischemia.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 33 条
  • [1] [Anonymous], 2014, FOR CLIN CORN
  • [2] Bidd H, 2013, PERIOPER MED-LONDON, V2, DOI 10.1186/2047-0525-2-11
  • [3] Effect of cerebral circulatory arrest on cerebral near-infrared spectroscopy in pediatric patients
    Blohm, Martin E.
    Obrecht, Denise
    Hartwich, Jana
    Singer, Dominique
    [J]. PEDIATRIC ANESTHESIA, 2014, 24 (04) : 393 - 399
  • [4] Comparison of near-infrared spectroscopy and tissue Po2 time series in patients after severe head injury and aneurysmal subarachnoid hemorrhage
    Brawanski, A
    Faltermeier, R
    Rothoerl, RD
    Woertgen, C
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (05) : 605 - 611
  • [5] Near-infrared spectroscopy -: not useful to monitor cerebral oxygenation after severe brain injury
    Büchner, K
    Meixensberger, J
    Dings, J
    Roosen, K
    [J]. ZENTRALBLATT FUR NEUROCHIRURGIE, 2000, 61 (02): : 69 - 73
  • [6] Guidelines for the Management of Severe Traumatic Brain Injury: Editor's commentary
    Bullock, M. Ross
    Povlishock, John T.
    [J]. JOURNAL OF NEUROTRAUMA, 2007, 24 : VII - VIII
  • [7] Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation A Comparison of Three Cerebral Oximetty Technologies
    Davie, Sophie N.
    Grocott, Hilary P.
    [J]. ANESTHESIOLOGY, 2012, 116 (04) : 834 - 840
  • [8] Diaz-Arrastia R, 2014, BRAIN TISSUE OXYGEN
  • [9] Optical Bedside Monitoring of Cerebral Blood Flow in Acute Ischemic Stroke Patients During Head-of-Bed Manipulation
    Favilla, Christopher G.
    Mesquita, Rickson C.
    Mullen, Michael
    Durduran, Turgut
    Lu, Xiangping
    Kim, Meeri N.
    Minkoff, David L.
    Kasner, Scott E.
    Greenberg, Joel H.
    Yodh, Arjun G.
    Detre, John A.
    [J]. STROKE, 2014, 45 (05) : 1269 - 1274
  • [10] Frequency domain near-infrared spectroscopy technique in the assessment of brain oxygenation: A validation study in live subjects and cadavers
    Gatto, Rodolfo
    Hoffman, William
    Mueller, Mark
    Flores, Arthur
    Valyi-Nagy, Tibor
    Charbel, Fady T.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2006, 157 (02) : 274 - 277