Does higher sampling rate (multiband plus SENSE) improve group statistics - An example from social neuroscience block design at 3T

被引:16
作者
Bhandari, Ritu [1 ]
Kirilina, Evgeniya [2 ,3 ]
Caan, Matthan [4 ,5 ]
Suttrup, Judith [1 ]
De Sanctis, Teresa [1 ]
De Angelis, Lorenzo [1 ]
Keysers, Christian [1 ,6 ]
Gazzola, Valeria [1 ,6 ]
机构
[1] KNAW, Netherlands Inst Neurosci, Amsterdam, Netherlands
[2] Free Univ, Ctr Cognit Neurosci, Berlin, Germany
[3] Max Plank Inst Human Cognit & Brain Sci, Leipzig, Germany
[4] Spinoza Ctr Neuroimaging, Amsterdam, Netherlands
[5] Univ Amsterdam, Biomed Engn & Phys, Amsterdam UMC, Amsterdam, Netherlands
[6] Univ Amsterdam, Dept Psychol, Amsterdam, Netherlands
基金
欧洲研究理事会;
关键词
TASK-BASED FMRI; RESTING-STATE; WHOLE-BRAIN; HIGH-RESOLUTION; FUNCTIONAL MRI; TEMPORAL RESOLUTION; REPETITION TIME; ECHO EPI; BOLD; SENSITIVITY;
D O I
10.1016/j.neuroimage.2020.116731
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Multiband (MB) or Simultaneous multi-slice (SMS) acquisition schemes allow the acquisition of MRI signals from more than one spatial coordinate at a time. Commercial availability has brought this technique within the reach of many neuroscientists and psychologists. Most early evaluation of the performance of MB acquisition employed resting state fMRI or the most basic tasks. In this study, we tested whether the advantages of using MB acquisition schemes generalize to group analyses using a cognitive task more representative of typical cognitive neuroscience applications. Twenty-three subjects were scanned on a Philips 3 T scanner using five sequences, up to eight-fold acceleration with MB-factors 1 to 4, SENSE factors up to 2 and corresponding TRs of 2.45s down to 0.63s, while they viewed (i) movie blocks showing complex actions with hand object interactions and (ii) control movie blocks without hand object interaction. Data were processed using a widely used analysis pipeline implemented in SPM12 including the unified segmentation and canonical HRF modelling. Using random effects group-level, voxel-wise analysis we found that all sequences were able to detect the basic action observation network known to be recruited by our task. The highest t-values were found for sequences with MB4 acceleration. For the MB1 sequence, a 50% bigger voxel volume was needed to reach comparable t-statistics. The group-level t-values for resting state networks (RSNs) were also highest for MB4 sequences. Here the MB1 sequence with larger voxel size did not perform comparable to the MB4 sequence. Altogether, we can thus recommend the use of MB4 (and SENSE 1.5 or 2) on a Philips scanner when aiming to perform group-level analyses using cognitive block design fMRI tasks and voxel sizes in the range of cortical thickness (e.g. 2.7 mm isotropic). While results will not be dramatically changed by the use of multiband, our results suggest that MB will bring a moderate but significant benefit.
引用
收藏
页数:18
相关论文
共 90 条
[1]  
Abdelgabar A.R., 2018, BIORXIV, DOI [10.1101/480293, DOI 10.1101/480293]
[2]   Tradeoffs in pushing the spatial resolution of fMRI for the 7T Human Connectome Project [J].
An Thanh Vu ;
Jamison, Keith ;
Glasser, Matthew F. ;
Smith, Stephen M. ;
Coalson, Timothy ;
Moeller, Steen ;
Auerbach, Edward J. ;
Ugurbil, Kamil ;
Yacoub, Essa .
NEUROIMAGE, 2017, 154 :23-32
[3]   μ-Suppression during Action Observation and Execution Correlates with BOLD in Dorsal Premotor, Inferior Parietal, and SI Cortices [J].
Arnstein, Dan ;
Cui, Fang ;
Keysers, Christian ;
Maurits, Natasha M. ;
Gazzola, Valeria .
JOURNAL OF NEUROSCIENCE, 2011, 31 (40) :14243-14249
[4]   Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses [J].
Auerbach, Edward J. ;
Xu, Junqian ;
Yacoub, Essa ;
Moeller, Steen ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) :1261-1267
[5]   Group-level impacts of within- and between-subject hemodynamic variability in fMRI [J].
Badillo, Solveig ;
Vincent, Thomas ;
Ciuciu, Philippe .
NEUROIMAGE, 2013, 82 :433-448
[6]   Simultaneous Multislice (SMS) Imaging Techniques [J].
Barth, Markus ;
Breuer, Felix ;
Koopmans, Peter J. ;
Norris, David G. ;
Poser, Benedikt A. .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) :63-81
[7]   A component based noise correction method (CompCor) for BOLD and perfusion based fMRI [J].
Behzadi, Yashar ;
Restom, Khaled ;
Liau, Joy ;
Liu, Thomas T. .
NEUROIMAGE, 2007, 37 (01) :90-101
[8]  
Bhandari R., 2019, BIORXIV, DOI [10.1101/756361., DOI 10.1101/756361]
[9]   Multiband Phase-Constrained Parallel MRI [J].
Blaimer, Martin ;
Choli, Morwan ;
Jakob, Peter M. ;
Griswold, Mark A. ;
Breuer, Felix A. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) :974-980
[10]  
Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd