Axial resolution enhancement for planar Airy beam light-sheet microscopy via the complementary beam subtraction method

被引:4
|
作者
Liu, Chao [1 ,2 ]
Yu, Xianghua [1 ]
Bai, Chen [1 ]
Li, Xing [1 ,2 ]
Zhou, Yuan [1 ,2 ]
Yan, Shaohui [1 ]
Min, Junwei [1 ]
Dan, Dan [1 ]
Li, Runze [1 ]
Gu, Shuangyu [1 ,2 ]
Yao, Baoli [1 ,2 ]
机构
[1] Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian 710119, Shaanxi, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
ILLUMINATION MICROSCOPY; FLUORESCENCE MICROSCOPY; RECONSTRUCTION; EXCITATION; EMBRYOS;
D O I
10.1364/AO.441070
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Airy beam light-sheet illumination can extend the field of view (FOV) of light-sheet fluorescence microscopy due to the unique propagation properties of non-diffraction and self-acceleration. However, the side lobes create undesirable out-of-focus background, leading to poor axial resolution and low image contrast. Here, we propose an Airy complementary beam subtraction (ACBS) method to improve the axial resolution while keeping the extended FOV. By scanning the optimized designed complementary beam that has two main lobes (TML), the generated complementary light-sheet has almost identical intensity distribution to that of the planar Airy light-sheet except for the central lobe. Subtraction of the two images acquired by double exposure respectively using the planar Airy light-sheet and the planar TML light-sheet can effectively suppress the influence of the out-of-focus background. The axial resolution improves from similar to 4 mu m to 1.2 mu m. The imaging performance was demonstrated by imaging specimens of aspergillus conidiophores and GFP labeled mouse brain section. The results show that the ACBS method enables the Airy beam light-sheet fluorescence microscopy to obtain better imaging quality. (C) 2021 Optical Society of America
引用
收藏
页码:10239 / 10245
页数:7
相关论文
共 50 条
  • [31] Resolution doubling in light-sheet microscopy via oblique plane structured illumination
    Chen, Bingying
    Chang, Bo-Jui
    Roudot, Philippe
    Zhou, Felix
    Sapoznik, Etai
    Marlar-Pavey, Madeleine
    Hayes, James B.
    Brown, Peter T.
    Zeng, Chih-Wei
    Lambert, Talley
    Friedman, Jonathan R.
    Zhang, Chun-Li
    Burnette, Dylan T.
    Shepherd, Douglas P.
    Dean, Kevin M.
    Fiolka, Reto P.
    NATURE METHODS, 2022, 19 (11) : 1419 - +
  • [32] Resolution doubling in light-sheet microscopy via oblique plane structured illumination
    Bingying Chen
    Bo-Jui Chang
    Philippe Roudot
    Felix Zhou
    Etai Sapoznik
    Madeleine Marlar-Pavey
    James B. Hayes
    Peter T. Brown
    Chih-Wei Zeng
    Talley Lambert
    Jonathan R. Friedman
    Chun-Li Zhang
    Dylan T. Burnette
    Douglas P. Shepherd
    Kevin M. Dean
    Reto P. Fiolka
    Nature Methods, 2022, 19 : 1419 - 1426
  • [33] Reflected Beam Light-Sheet Microscopy for Whole-Cell 3D Super-Resolution Imaging
    Meddens, Marjolein B. M.
    Liu, Sheng
    James, Conrad D.
    Lidke, Keith A.
    BIOPHYSICAL JOURNAL, 2015, 108 (02) : 35A - 35A
  • [34] Light-sheet microscopy in a glass capillary: feedback holographic control for illumination beam correction
    Meinert, Tobias
    Gutwein, Benjamin Alexander
    Rohrbach, Alexander
    OPTICS LETTERS, 2017, 42 (02) : 350 - 353
  • [35] How to define and optimize axial resolution in light-sheet microscopy: a simulation-based approach
    Remacha, Elena
    Friedrich, Lars
    Vermot, Julien
    Fahrbach, Florian O.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (01) : 8 - 26
  • [36] Enhancement of image quality and imaging depth with Airy light-sheet microscopy in cleared and non-cleared neural tissue
    Nylk, Jonathan
    McCluskey, Kaley
    Aggarwal, Sanya
    Tello, Javier A.
    Dholakia, Kishan
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (10): : 4021 - 4033
  • [37] Sidelobe suppression in light-sheet fluorescence microscopy with Bessel beam plane illumination using subtractive imaging
    邓素辉
    肖轶平
    胡杰
    陈建芳
    王玉皞
    刘明萍
    Chinese Optics Letters, 2018, 16 (11) : 65 - 69
  • [38] Sidelobe suppression in light-sheet fluorescence microscopy with Bessel beam plane illumination using subtractive imaging
    Deng, Suhui
    Xiao, Yiping
    Hu, Jie
    Chen, Jianfang
    Wang, Yuhao
    Liu, Mingping
    CHINESE OPTICS LETTERS, 2018, 16 (11)
  • [39] The suppression of the side lobes of the fluorescence light-sheet microscopy with scanned Bessel beam by using the leaky filter
    Ding, Zijun
    Hu, Luohong
    Yuan, Liusong
    Yuan, Deyi
    Li, Xianhong
    Zhang, Yulong
    Deng, Suhui
    ADVANCED OPTICAL IMAGING TECHNOLOGIES III, 2020, 11549
  • [40] Temporal resolution doubling in fluorescence light-sheet microscopy via a hue-encoded shutter and regularization
    Jaques, Christian
    Ernst, Alexander
    Mercader, Nadia
    Liebling, Michael
    OSA CONTINUUM, 2020, 3 (08) : 2195 - 2209