Thermal Analysis of Parabolic Trough Solar Collector and Assessment of Steam Power Potential at Two Locations in Cameroon

被引:0
作者
Nguimdo, L. Akana [1 ]
Teka, Josiane [2 ]
Fopossie, Frank D. [2 ]
机构
[1] Univ Buea, Fac Engn & Technol, Dept Elect & Elect Engn, POB 63, Buea, Cameroon
[2] Univ Yaounde I, Environm Energy Technol Lab EETL, Fac Sci, POB 812, Yaounde, Cameroon
来源
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH | 2021年 / 11卷 / 03期
关键词
Parabolic Trough Collector; Steam Potential; Heat Exchange; Generation Mode; Calorific Fluid; PERFORMANCE; PLANT;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
the past two decades, Cameroon has devoted enormous financial resources to the construction of thermal power plants operating on Heavy Fuel Oil. Despite these efforts, it has been noted that the production of electricity from fossil sources has not been up to the expectations of the population. In this context, it becomes a necessity to explore other sources of energy production most precisely renewable sources. This paper is concerned with the assessment of the steam production potential from solar sources in the stations of Maroua and Yaounde using Parabolic Trough Collectors. Two production modes are considered in this study: The direct mode using water and the indirect mode with TherminolVP1 as heat transfer fluid. The system is modeled based on the study of the energy balance between the receiver and the calorific fluids in order to assess the impact of the irradiance on the calorific fluid outlet temperature at hourly time scale over the day. The assessment of the collector characteristics shows an optical efficiency varying between 0.73 and 0.75 while the overall heat loss coefficient extends over wide ranges depending on the environmental conditions and generation mode. It was shown that the temperature of the steam increases with the number of collectors. For an association of 8 collectors, the average daily production time of pressurized steam at 40bars is 8 hours with a maximum temperature of 600 degrees C in direct mode and 490 degrees C in indirect mode for the month of February in Maroua. The maximum thermal efficiency for the same month is 72.7% in direct generation and 60.7% in indirect generation. These results confirm the real steam potential for electricity generation for complementing existing heavy fuel oil stations with solar sources for better supply. However, further investigations about the energy demand and the supply are necessary for appropriate sizing of the solar generator.
引用
收藏
页码:1136 / 1148
页数:13
相关论文
共 33 条
  • [1] An extensive review of various technologies for enhancing the thermal and optical performances of parabolic trough collectors
    Abed, Nabeel
    Afgan, Imran
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (07) : 5117 - 5164
  • [2] Ahmed MH, 2017, INT CONF RENEW ENERG, P304, DOI 10.1109/ICRERA.2017.8191284
  • [3] Al-Hajj R, 2017, INT CONF RENEW ENERG, P195, DOI 10.1109/ICRERA.2017.8191265
  • [4] Al-Oran O., 2020, POLLACK PERIOD, V15, P187
  • [5] Ali L., 2021, CLEANER ENG TECHNOLO, DOI [10.1016/j.clet.2021.10006, DOI 10.1016/J.CLET.2021.10006]
  • [6] [Anonymous], 2015, ASIAN J CURR ENG MAT
  • [7] Asma M, 2018, INT CONF RENEW ENERG, P993, DOI 10.1109/ICRERA.2018.8566976
  • [8] An assessment of the energy generation potential of photovoltaic systems in Cameroon using satellite-derived solar radiation datasets
    Ayompe, L. M.
    Duffy, A.
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2014, 7 : 257 - 264
  • [9] Dynamic Modeling of the Solar Field in Parabolic Trough Solar Power Plants
    Barcia, Lourdes A.
    Peon Menendez, Rogelio
    Martinez Esteban, Juan A.
    Jose Prieto, Miguel A.
    Martin Ramos, Juan A.
    de Cos Juez, F. Javier
    Nevado Reviriego, Antonio
    [J]. ENERGIES, 2015, 8 (12) : 13361 - 13377
  • [10] A novel parabolic trough solar collector model - Validation with experimental data and comparison to Engineering Equation Solver (EES)
    Behar, Omar
    Khellaf, Abdallah
    Mohammedi, Kamal
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 268 - 281