An improved CFD modeling approach applied for the simulation of gas-liquid interaction in the ozone contactor along with structure optimization

被引:12
作者
Chen, Xiangyu [1 ]
Yao, Juanjuan [1 ]
Jiang, Sunny C. [2 ]
Liu, Cun [1 ]
Guo, Meng [1 ]
Gao, Naiyun [3 ]
Zhang, Zhi [1 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Chongqing 400045, Peoples R China
[2] Univ Calif Irvine, Dept Civil & Environm Engn, Irvine, CA 92617 USA
[3] Tongji Univ, State Key Lab Pollut Control & Resources Reuse, Shanghai 200092, Peoples R China
关键词
Ozone contactor; Computational fluid dynamics; Disinfection; Ozone mass transfer; COMPUTATIONAL FLUID-DYNAMICS; FLOW REGIME; DISINFECTION; REACTOR; DESIGN; WATER; HYDRODYNAMICS; VELOCITIES; OZONATION; TRANSPORT;
D O I
10.1016/j.cej.2019.123322
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An improved two-phase computational fluid dynamics (CFD) model has been developed by incorporation of Eulerian-Eulerian approach and user defined function (UDF) to address the liquid-gas flow and ozone reaction in an ozone contactor. Besides, a novel structure optimization design was proposed to improve the performance of contactor. Tracer residence time distribution (RTD) and distribution of CT value were applied as the indicators of contactor performance by conventional single phase model and improved two-phase model, respectively. The validation tests revealed that the improved two-phase CFD model is a reliable tool for the simulation of ozone contactor performance with good accuracy. The simulated results showed that this optimization design can greatly reduce the short-circuiting and dead zone in the contactor, along with the improvement of ozone mass transfer efficiency. Also much higher improvement of average CT value (310% increment) than the improvement of baffling factor (48.8% increment) denotes that the two-phase model is recommendable in the future study, and the use of baffling factor will underestimate the performance of ozone contactor.
引用
收藏
页数:10
相关论文
共 56 条
  • [1] Predicting the disinfection efficiency range in chlorine contact tanks through a CFD-based approach
    Angeloudis, Athanasios
    Stoesser, Thorsten
    Falconer, Roger A.
    [J]. WATER RESEARCH, 2014, 60 : 118 - 129
  • [2] [Anonymous], 1988, Mathematical Statistics and Data Analysis
  • [3] [Anonymous], 1993, PARTICULATE 2 PHASE
  • [4] [Anonymous], 2015, ANSYS Fluent User's Guide
  • [5] Aral MM, 2017, J ENVIRON ENG, V143, DOI [10.1061/(asce)ee.1943-7870.0001266, 10.1061/(ASCE)EE.1943-7870.0001266]
  • [6] Bartrand T.A., 2006, High resolution experimental studies and numerical analysis of fine bubble ozone disinfection contactors
  • [7] Modelling of Ozone Mass-Transfer through Non-Porous Membranes for Water Treatment
    Berry, Matthew J.
    Taylor, Caitlin M.
    King, William
    Chew, Y. M. John
    Wenk, Jannis
    [J]. WATER, 2017, 9 (07):
  • [8] The pseudo-homogeneous flow regime in large-scale bubble columns: experimental benchmark and computational fluid dynamics modeling (vol 5, pg 141, 2019)
    Besagni, Giorgio
    [J]. PETROLEUM, 2021, 7 (02) : 141 - 160
  • [9] Computational fluid-dynamic modeling of the mono-dispersed homogeneous flow regime in bubble columns
    Besagni, Giorgio
    Guedon, Gael R.
    Inzoli, Fabio
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2018, 331 : 222 - 237
  • [10] The dual effect of viscosity on bubble column hydrodynamics
    Besagni, Giorgio
    Inzoli, Fabio
    De Guido, Giorgia
    Pellegrini, Laura Annamaria
    [J]. CHEMICAL ENGINEERING SCIENCE, 2017, 158 : 516 - 545