Initial United Kingdom experience with the use of permanent, biventricular pacemakers - Implantation procedure and technical considerations

被引:19
作者
Walker, S [1 ]
Levy, T [1 ]
Rex, S [1 ]
Brant, S [1 ]
Paul, V [1 ]
机构
[1] Harefield Hosp, Royal Brompton & Harefield NHS Trust, Dept Cardiol, Harefield UB9 6JH, Middx, England
来源
EUROPACE | 2000年 / 2卷 / 03期
关键词
biventricular pacemaker; heart failure;
D O I
10.1053/eupc.2000.0106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To describe the institution of a biventricular pacing programme with particular reference to the implantation procedure and new technological considerations. Methods and Results Analysis of outcomes of a consecutive series of 54 patients undergoing attempted biventricular pacemaker implantation between February 1998 and April 1999. Successful implantation was achieved in 49 of the 54 patients (91%). Five patients required lead repositioning after initial successful implantation. Left ventricular lead pacing thresholds were found to be satisfactory and stable in the long term, with pacing thresholds of 1.3 V, 1.9 V and 1.6 V at implantation, 1 and 3 months, respectively. Left-sided lead function was not dependent on lead position within the tributaries of the coronary sinus. The implantation procedure was found to be safe, although one patient died during long-term follow-up. Conclusion With appropriate previous experience in complex and coronary sinus pacing and with access to up-to-date pacemaker and lead technology, a biventricular pacemaker implantation service can be instituted with good medium-term results. (Europace 2000; 2: 233-239) (C) 2000 The European Society of Cardiology.
引用
收藏
页码:233 / 239
页数:7
相关论文
共 11 条
[1]  
Auricchio A, 1999, AM J CARDIOL, V83, p130D
[2]   Assessment of left ventricular pacing in patients with severe cardiac failure after atrioventricular node ablation and right ventricular pacing for permanent atrial fibrillation [J].
Blanc, JJ ;
Etienne, Y ;
Gilard, M .
EUROPACE, 1999, 1 (01) :47-48
[3]  
Blanc JJ, 1997, CIRCULATION, V96, P3273
[4]   Multisite pacing for end-stage heart failure: Early experience [J].
Cazeau, S ;
Ritter, P ;
Lazarus, A ;
Gras, D ;
Backdach, H ;
Mundler, O ;
Mugica, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1748-1757
[5]   Permanent left ventricular pacing with transvenous leads inserted into the coronary veins [J].
Daubert, JC ;
Ritter, P ;
Le Breton, H ;
Gras, D ;
LeClercq, C ;
Lazarus, A ;
Mugica, J ;
Mabo, P ;
Cazeau, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :239-245
[6]  
GOLDMAN S, 1993, CIRCULATION, V87, P24
[7]   Multisite pacing as a supplemental treatment of congestive heart failure: Preliminary results of the Medtronic Inc. InSync study [J].
Gras, D ;
Mabo, P ;
Tang, T ;
Luttikuis, O ;
Chatoor, R ;
Pedersen, AK ;
Tscheliessnigg, HH ;
Deharo, JC ;
Puglisi, A ;
Silvestre, J ;
Kimber, S ;
Ross, H ;
Ravazzi, A ;
Paul, V ;
Skehan, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2249-2255
[8]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335
[9]   Endocardial biventricular pacing [J].
Jaïs, P ;
Douard, H ;
Shah, DC ;
Barold, S ;
Barat, JL ;
Clémenty, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2128-2131
[10]   Acute effects of intraoperative multisite ventricular pacing on left ventricular function and activation/contraction sequence in patients with depressed ventricular function [J].
Saxon, LA ;
Kerwin, WF ;
Cahalan, MK ;
Kalman, JM ;
Olgin, JE ;
Foster, E ;
Schiller, NB ;
Shinbane, JS ;
Lesh, MD ;
Merrick, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (01) :13-21