24-hour monitoring of intraocular pressure in glaucoma management: A retrospective review

被引:214
作者
Hughes, E [1 ]
Spry, P [1 ]
Diamond, J [1 ]
机构
[1] Bristol Eye Hosp, Bristol BS1 2LX, Avon, England
关键词
circadian rhythm; diurnal variation; glaucoma; intraocular pressure;
D O I
10.1097/00061198-200306000-00009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Diurnal variation in intraocular pressure (IOP) is well recognized, yet important decisions in glaucoma management are frequently made after 1 or 2 IOP measurements. Twenty-four-hour monitoring of IOP may identify IOP variation and spikes. This study determined the value of 24-hour IOP monitoring in routine clinical practice. Methods: Data were acquired retrospectively from case notes of 29 glaucoma patients sequentially admitted for 24-hour IOP monitoring while taking their established antiglaucoma therapy. Results: While there was no difference between the mean clinic (office) and mean 24-hour IOP measurements, the peak IOP during 24-hour monitoring was on average 4.9 mm Hg higher than the peak clinic IOP (P<0.0001). In 4 (13.8%) patients, the peak IOP over 24 hours was at least 12 mm Hg higher than the clinic peak. Peak IOP values occurred outside normal office hours in 51.7% of patients. Twenty-four-hour IOP monitoring resulted in a change of clinical management in 23 (79.3%) patients, including 13 (44.8%) who were offered trabeculectomy. Conclusion: Twenty-four-hour monitoring of IOP frequently led to a change of glaucoma management by identifying IOP fluctuations and spikes. High IOP and wide diurnal IOP variation are considered major risk factors for glaucoma progression, and standard clinic follow-up evaluations failed to identify these phenomena.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 22 条
[1]  
ALPAR JJ, 1983, GLAUCOMA, V5, P130
[2]  
Asrani S, 2000, J GLAUCOMA, V9, P134
[3]   Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer [J].
Bafa, M ;
Lambrinakis, I ;
Dayan, M ;
Birch, M .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (01) :15-18
[4]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[5]  
Ederer F, 2000, ARCH OPHTHALMOL-CHIC, V118, P1639
[6]   Attempted eyelid closure affects intraocular pressure measurement [J].
Gandhi, PD ;
Gürses-Özden, R ;
Liebmann, JM ;
Ritch, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 131 (04) :417-420
[7]   Increased corneal thickness in patients with ocular hypertension [J].
Herman, DC ;
Hodge, DO ;
Bourne, WM .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (03) :334-336
[8]   New TonoPen XL: comparison with the Goldmann tonometer [J].
Iester, M ;
Mermoud, A ;
Achache, F ;
Roy, S .
EYE, 2001, 15 (1) :52-58
[9]  
Ishida K, 1998, J GLAUCOMA, V7, P372
[10]   HOME TONOMETRY [J].
JENSEN, AD ;
MAUMENEE, AE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1973, 76 (06) :929-932