On-Chip Micro-Electro-Mechanical System Fourier Transform Infrared (MEMS FT-IR) Spectrometer-Based Gas Sensing

被引:120
作者
Erfan, Mazen [1 ]
Sabry, Yasser M. [1 ,2 ]
Sakr, Mohammad [1 ]
Mortada, Bassem [2 ]
Medhat, Mostafa [2 ]
Khalil, Diaa [1 ,2 ]
机构
[1] Ain Shams Univ, Fac Engn, 1 Elsarayat St, Cairo, Egypt
[2] Si Ware Syst, Cairo, Egypt
关键词
Gas detection; micro-electro-mechanical systems; MEMS technology; micro-optical bench technology; mid-infrared spectrometer; MIR spectrometer; near-infrared; NIR spectroscopy; portable spectrometer; spectral-based sensor; QUANTITATIVE-ANALYSIS; ACETYLENE; H2O;
D O I
10.1177/0003702816638295
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work, we study the detection of acetylene (C2H2), carbon dioxide (CO2) and water vapor (H2O) gases in the near-infrared (NIR) range using an on-chip silicon micro-electro-mechanical system (MEMS) Fourier transform infrared (FT-IR) spectrometer in the wavelength range 1300-2500nm (4000-7692cm(-1)). The spectrometer core engine is a scanning Michelson interferometer micro-fabricated using a deep-etching technology producing self-aligned components. The light is free-space propagating in-plane with respect to the silicon chip substrate. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator corresponding to about 30cm(-1) resolution. Multi-mode optical fibers are used to connect light between the wideband light source, the interferometer, the 10cm gas cell, and the optical detector. A wide dynamic range of gas concentration down to 2000 parts per million (ppm) in only 10cm length gas cell is demonstrated. Extending the wavelength range to the mid-infrared (MIR) range up to 4200nm (2380cm(-1)) is also experimentally demonstrated, for the first time, using a bulk micro-machined on-chip MEMS FT-IR spectrometer. The obtained results open the door for an on-chip optical gas sensor for many applications including environmental sensing and industrial process control in the NIR/MIR spectral ranges.
引用
收藏
页码:897 / 904
页数:8
相关论文
共 37 条
[1]   Signal-to-noise ratio calculation in a moving-optical-wedge spectrometer [J].
Al-Saeed, Tarek A. ;
Khalil, Diaa A. .
APPLIED OPTICS, 2012, 51 (30) :7206-7213
[2]  
Dami M., 2010, ICSO 2010 RHOD GREEC
[3]   Design and implementation of a sub-nm resolution microspectrometer based on a Linear-Variable Optical Filter [J].
Emadi, Arvin ;
Wu, Huaiwen ;
de Graaf, Ger ;
Wolffenbuttel, Reinoud .
OPTICS EXPRESS, 2012, 20 (01) :489-507
[5]   SPECTRAL EMISSIVITIES + INTEGRATED INTENSITIES OF 1.87-,1.38-, + 1.14-MU H2O BANDS BETWEEN 1000 DEGREES + 2200 DEGREES K [J].
FERRISO, CC ;
LUDWIG, CB .
JOURNAL OF CHEMICAL PHYSICS, 1964, 41 (06) :1668-&
[6]  
Gilbert S.L., 2001, ACETYLENE C2H2 ABSOR
[7]   Synthetic calibration and quantitative analysis of gas-phase FT-IR spectra [J].
Griffith, DWT .
APPLIED SPECTROSCOPY, 1996, 50 (01) :59-70
[8]  
Griffiths P.R., 2006, FOURIER TRANSFORM IN
[9]  
Gu Y., 2002, US, Patent No. 6373574
[10]   IMPROVED SENSITIVITY OF INFRARED-SPECTROSCOPY BY THE APPLICATION OF LEAST-SQUARES METHODS [J].
HAALAND, DM ;
EASTERLING, RG .
APPLIED SPECTROSCOPY, 1980, 34 (05) :539-548