Selective and High-Performance Electrochemical Sensor for Cadmium Ions Based on Intimate Binary Spinel CoMn2O4 Nanostructures

被引:16
作者
Balaji, Ramachandran [1 ]
Renganathan, Vengudusamy [1 ]
Chen, Shen-Ming [1 ]
Singh, Vyoma [2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
[2] Indian Inst Technol Mandi, Sch Comp & Elect Engn, Mandi, Himachal Prades, India
来源
CHEMISTRYSELECT | 2019年 / 4卷 / 45期
关键词
CoMn2O4; nanostructures; electrochemical sensing; environmental monitoring; Heavy Metals; water; ANODIC-STRIPPING VOLTAMMETRY; HEAVY-METALS; ICP-MS; WATER; CD; OXIDE; PB; POLLUTION; ELECTRODE; SAMPLES;
D O I
10.1002/slct.201902573
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Due to an exponential increase in the industrialization and processing of raw materials had duly resulted in the rapid contamination of heavy metals in the land and water. For the sustainable ecosystem and high standard human life, an analytical quantification of cadmium in drinking water, chocolates, drinks and other environmental systems is of greater importance. The current public welfare sector is in high demand for the rational design and fabrication of the economical, user friendly and point of care device for the sensing of toxic heavy metal cadmium in water. In combination with high sensing performance, the sensor must also be highly robust, selective and good reproducibility upon detection. With the understanding of the facts, we report a novel and direct electrochemical based sensing of cadmium ions based on CoMn2O4 nanostructures in the water. Linear Sweep Voltammetry (LSV) was employed for the investigation of cadmium ions detection at a lower concentration for the unswerving electrochemical sensing on a CoMn2O4 nanostructure matrix. Since, the LSV works on the unidirectional sweep principle it eliminates the possible interference of other elements during the reverse sweep. This analytical process is very reliable, low cost and ultrasensitive upon others. The fabricated CoMn2O4 nanostructure modified electrode displayed good sensitivity 3.3454 mu A mu M-1 cm(-2) and limit of detection 0.0124 mu M with a linear range varying up to 0.1 to 761 mu M.
引用
收藏
页码:13123 / 13130
页数:8
相关论文
共 35 条
[21]   ICP-MS analysis of a series of metals (Namely:: Mg, Cr, Co, Ni, Fe, Cu, Zn, Sn, Cd and Pb) in black and green olive samples from Bursa, Turkey [J].
Sahan, Yasemin ;
Basoglu, Fikri ;
Guecer, Seref .
FOOD CHEMISTRY, 2007, 105 (01) :395-399
[22]   In situ synthesis and properties of reduced graphene oxide/Bi nanocomposites: As an electroactive material for analysis of heavy metals [J].
Sahoo, P. K. ;
Panigrahy, Bharati ;
Sahoo, S. ;
Satpati, A. K. ;
Li, Dan ;
Bahadur, D. .
BIOSENSORS & BIOELECTRONICS, 2013, 43 :293-296
[23]   Status of heavy metals in water and bed sediments of river Gomti - A tributary of the Ganga River, India [J].
Singh, VK ;
Singh, KP ;
Mohan, D .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2005, 105 (1-3) :43-67
[24]   Highly improved sensitivity of TS-FF-AAS for Cd(II) determination at ng L-1 levels using a simple flow injection minicolumn preconcentration system with multiwall carbon nanotubes [J].
Teixeira Tarley, Cesar Ricardo ;
Barbosa, Adriano Francisco ;
Segatelli, Mariana Gava ;
Figueiredo, Eduardo Costa ;
Luccas, Pedro Orival .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) :1305-1313
[25]   Epidemiologic evidence of diabetogenic effect of arsenic [J].
Tseng, CH ;
Tseng, CP ;
Chiou, HY ;
Hsueh, YM ;
Chong, CK ;
Chen, CJ .
TOXICOLOGY LETTERS, 2002, 133 (01) :69-76
[26]   Determination and assessments of selected heavy metals in eye shadow cosmetics from China, Italy, and USA [J].
Volpe, M. G. ;
Nazzaro, M. ;
Coppola, R. ;
Rapuano, F. ;
Aquino, R. P. .
MICROCHEMICAL JOURNAL, 2012, 101 :65-69
[27]   Enhancing electrochemical reaction sites in nickel-cobalt layered double hydroxides on zinc tin oxide nanowires: a hybrid material for an asymmetric supercapacitor device [J].
Wang, Xu ;
Sumboja, Afriyanti ;
Lin, Mengfang ;
Yan, Jian ;
Lee, Pooi See .
NANOSCALE, 2012, 4 (22) :7266-7272
[28]   Sensitive electrochemical determination of trace cadmium on a stannum film/poly(p-aminobenzene sulfonic acid)/electrochemically reduced graphene composite modified electrode [J].
Wang, Zhiqiang ;
Wang, Hui ;
Zhang, Zhihao ;
Yang, Xiaojing ;
Liu, Gang .
ELECTROCHIMICA ACTA, 2014, 120 :140-146
[29]   SnO2/Reduced Graphene Oxide Nanocomposite for the Simultaneous Electrochemical Detection of Cadmium(II), Lead(II), Copper(II), and Mercury(II): An Interesting Favorable Mutual Interference [J].
Wei, Yan ;
Gao, Chao ;
Meng, Fan-Li ;
Li, Hui-Hua ;
Wang, Lun ;
Liu, Jin-Huai ;
Huang, Xing-Jiu .
JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (01) :1034-1041
[30]  
WHO, 2013, SUSTAINING THE DRIVE TO OVERCOME THE GLOBAL IMPACT OF NEGLECTED TROPICAL DISEASES: SECOND WHO REPORT ON NEGLECTED TROPICAL DISEASES, P1