PDMS-coated no-core fiber interferometer with enhanced sensitivity for temperature monitoring applications

被引:24
|
作者
Yi, Duo [1 ,2 ,3 ]
Huo, Zhenwei [1 ]
Geng, Youfu [1 ,2 ,3 ]
Li, Xuejin [2 ,3 ,4 ]
Hong, Xueming [1 ,2 ,3 ]
机构
[1] Shenzhen Univ, Coll Phys & Optoelect Engn, Shenzhen 518060, Peoples R China
[2] Shenzhen Key Lab Sensor Technol, Shenzhen 518060, Peoples R China
[3] Shenzhen Engn Lab Opt Fiber Sensors & Networks, Shenzhen 518060, Peoples R China
[4] Chinese Univ Hong Kong, Shenzhen 518060, Peoples R China
关键词
Fiber optic interferometer; No-core fiber; PDMS; Temperature measurement; STRAIN SENSOR;
D O I
10.1016/j.yofte.2020.102185
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study proposed a PDMS-coated no-core fiber interferometer for temperature monitoring. The fiber optic interferometer is based on a cascaded structure of single-mode fiber-no-core fiber-single-mode fiber (SMF-NCF-SMF), and a PDMS layer is coated onto the interferometer surface to perform as the adhesive packaging layer. When compared with the pure silica fiber interferometer, the coated PDMS owns excellent thermal performances, resulting in a dramatic sensitivity improvement of temperature. Besides, since the fiber structure itself is fragile, the coated PDMS can also protect the sensor structure, which improves its reliability for practical applications. The experimental results verify that the proposed low-cost PDMS-coated fiber interferometer owns high sensitivity (200.2 pm/degrees C) for temperature measurement. It shows excellent consistency and repeatability within the thermal cycles from 40 degrees C to 80 degrees C. Thus, it is considered as a promising candidate to fabricate the fiber optic smart structure for temperature health monitoring applications.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Optical Sensing of Solvents using Selective Tensile Effects of a PDMS-Coated Fiber Bragg Grating
    Joo, Kyung-Il
    Han, Yeonjeong
    Park, Chang-sub
    Lee, Yong Wook
    Kong, Seong Ho
    Kang, Shin-Won
    Kim, Hak-Rin
    2010 IEEE SENSORS, 2010, : 1645 - 1648
  • [42] High sensitivity open-cavity Mach-Zehnder interferometer based on no-core fiber for seawater salinity measurement
    Yan, Jinmeng
    Zhang, Ailing
    Cheng, Qihang
    Li, Wen
    Sun, Ce
    OPTIK, 2021, 227 (227):
  • [43] Humidity and temperature sensor based on GOQDs-PVA coated tapered no-core fiber combined with FBG
    程启航
    张爱玲
    潘洪刚
    李雯
    孙策
    OptoelectronicsLetters, 2020, 16 (06) : 428 - 432
  • [44] High sensitivity curvature sensor based on a double-sphere tapered no-core fiber Mach-Zehnder interferometer
    Zhu, Xiaojun
    Pan, Yongquan
    Sun, Ang
    Sun, Dan
    Liu, Wen
    Cao, Juan
    Zhang, Guoan
    Han, Zhanghua
    Zou, Li
    Liang, Zhipeng
    Shi, Yuechun
    OPTICS AND LASER TECHNOLOGY, 2022, 155
  • [45] Humidity and temperature sensor based on GOQDs-PVA coated tapered no-core fiber combined with FBG
    Cheng, Qi-hang
    Zhang, Ai-ling
    Pan, Hong-gang
    Li, Wen
    Sun, Ce
    OPTOELECTRONICS LETTERS, 2020, 16 (06) : 428 - 432
  • [46] Fiber-optic temperature sensor based on a thinner no-core fiber
    Ma, Lin
    Kang, Zexin
    Qi, Yanhui
    Jian, Shuisheng
    OPTIK, 2015, 126 (9-10): : 1044 - 1046
  • [47] High sensitivity temperature sensor based on fiber air-microbubble Fabry-Perot interferometer with PDMS-filled hollow-core fiber
    Chen, Mao-qing
    Zhao, Yong
    Xia, Feng
    Peng, Yun
    Tong, Rui-jie
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 275 : 60 - 66
  • [48] Ammonia Gas Sensor Based on No-Core Fiber Coated with Zinc Oxide
    Luo Tong
    Huang Yi
    Deng Chuanlu
    Hu Chengyong
    Zhang Xiaobei
    Wang Tingyun
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (10):
  • [49] A robust duplex Cu/PDMS-coated mesh with superhydrophobic surface for applications in cleaning of spilled oil
    Zhu, Jingfang
    Wu, Liyun
    Li, Jingjing
    Liu, Bin
    Zeng, Zhixiang
    RSC ADVANCES, 2017, 7 (40): : 25101 - 25108
  • [50] Enhanced sensitivity of temperature sensor by a PCF with a defect core based on Sagnac interferometer
    Liu, Qiang
    Li, Shu-Guang
    Chen, Hailiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 636 - 641