Development of sensitive derivatization method for aldosterone in liquid chromatography-electrospray ionization tandem mass spectrometry of corticosteroids

被引:48
|
作者
Yamashita, Kouwa [1 ]
Okuyama, Mitsunobu [2 ]
Nakagawa, Risa [2 ]
Honma, Seijiro [2 ]
Satoh, Fumitoshi [3 ]
Morimoto, Ryo [3 ]
Ito, Sadayoshi [3 ]
Takahashi, Madoka [1 ]
Numazawa, Mitsuteru [1 ]
机构
[1] Tohoku Pharmaceut Univ, Fac Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9818558, Japan
[2] Teikoku Hormone Med Co Ltd, Takatsu Ku, Kanagawa 2138522, Japan
[3] Tohoku Univ, Grad Sch Med, Dept Med, Div Nephrol Endocrinol & Vasc Med,Aoba Ku, Sendai, Miyagi 9808575, Japan
关键词
aldosterone; high-performance liquid chromatography; electrospray ionization tandem mass; spectrometry; picolinyl ester; derivatization;
D O I
10.1016/j.chroma.2008.05.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive quantification method liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was investigated in a positive mode using recently developed picolinyl derivatization. Aldosterone was smoothly and quantitatively converted to the ethyl ether-picolinyl derivative by treatment with HCI-ethanol followed by the esterification with picolinic acid in the presence of 2-methyl-6-nitrobenzoic anhydride and 4-dimethylaminopyridine. The positive ion-ESI mass spectrum of the ethyl ether-picolinyl derivative was characterized by an appearance of protonated molecule ([M+H](+)) as a base peak. The ethyl ether-picolinyl derivatization gave a successful result in a separation of alclosterone from corticosterone, dehydrocorticosterone and cortexolone, and also provided an approximately 10-fold higher ESI response in the positive-LC-ESI-MS/MS (selected reaction monitoring; SRM) when compared to that of underivatized molecule (negative mode). The limit of quantification of aldosterone by SRM using ethyl ether-picolinyl derivatization (m/z 494 -- m1z 448) was 1 pg/0.2 ml serum with accuracy and precision of 92.6% and 5.6%, respectively. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [41] Development of an accurate and sensitive assay for 2-methoxyes-tradiol using derivatization and liquid chromatography-tandem mass spectrometry
    Takahashi, Koji
    Takiwaki, Masaki
    Fukuzawa, Seketsu
    Kikutani, Yoshikuni
    Abe, Kentaro
    Higashi, Tatsuya
    Kobayashi, Hironori
    PRACTICAL LABORATORY MEDICINE, 2025, 44
  • [42] Establishment of a rapid and simple liquid chromatography tandem mass spectrometry method for measuring aldosterone in urine
    Yin, Yicong
    Yu, Songlin
    Qiu, Ling
    Wang, Xiaoxia
    Wang, Danchen
    Ma, Chaochao
    Zhang, Kai
    You, Tingting
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1113 : 84 - 90
  • [43] Structural deduction of pregnane glycosides from Dregea sinensis Hemsl by high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry
    Jia, Shaohua
    Song, Juan
    Dai, Rongji
    Deng, Yulin
    Lv, Fang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 415 : 38 - 43
  • [44] Picogram per liter level determination of hydroxylated polybrominated diphenyl ethers in water by liquid chromatography-electrospray tandem mass spectrometry
    Chang, Hong
    Wu, Fengchang
    Jin, Fen
    Feng, Chenglian
    Zhao, Xiaoli
    Liao, Haiqing
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1223 : 131 - 135
  • [45] Application of high-performance liquid chromatography-electrospray ionization-mass spectrometry to measure microsomal membrane transport of glucuronides
    Staines, AG
    Burchell, B
    Bánhegyi, G
    Mandl, J
    Csala, M
    ANALYTICAL BIOCHEMISTRY, 2005, 342 (01) : 45 - 52
  • [46] Synthesis of benzofurazan derivatization reagents for carboxylic acids and its application to analysis of fatty acids in rat plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry
    Tsukamoto, Y
    Santa, T
    Saimaru, H
    Imai, K
    Funatsu, T
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) : 802 - 808
  • [47] Simultaneous determination of 13 phytohormones in oilseed rape tissues by liquid chromatography-electrospray tandem mass spectrometry and the evaluation of the matrix effect
    Fan, Sufang
    Wang, Xiupin
    Li, Peiwu
    Zhang, Qi
    Zhang, Wen
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (06) : 640 - 650
  • [48] Quantitative analysis of bromate in non-alcoholic beer using ultra performance liquid chromatography-electrospray ionization mass spectrometry
    Khan, Mohammad Rizwan
    Alothman, Zeid Abdullah
    Alqahtani, Nasser Judaya
    Alsohaimi, Ibrahim Hotan
    Naushad, Mu
    ANALYTICAL METHODS, 2014, 6 (12) : 4038 - 4045
  • [49] Analysis of Selected Sugars and Sugar Phosphates in Mouse Heart Tissue by Reductive Amination and Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Han, Jun
    Tschernutter, Vera
    Yang, Juncong
    Eckle, Tobias
    Borchers, Christoph H.
    ANALYTICAL CHEMISTRY, 2013, 85 (12) : 5965 - 5973
  • [50] The nebramycin aminoglycoside profiles of Streptomyces tenebrarius and their characterization using an integrated liquid chromatography-electrospray ionization-tandem mass spectrometric analysis
    Park, Je Won
    Park, Sung Ryeol
    Han, Ah Reum
    Ban, Yeon Hee
    Yoo, Young Ji
    Kim, Eun Ji
    Yoon, Yeo Joon
    ANALYTICA CHIMICA ACTA, 2010, 661 (01) : 76 - 84