Development of sensitive derivatization method for aldosterone in liquid chromatography-electrospray ionization tandem mass spectrometry of corticosteroids

被引:48
|
作者
Yamashita, Kouwa [1 ]
Okuyama, Mitsunobu [2 ]
Nakagawa, Risa [2 ]
Honma, Seijiro [2 ]
Satoh, Fumitoshi [3 ]
Morimoto, Ryo [3 ]
Ito, Sadayoshi [3 ]
Takahashi, Madoka [1 ]
Numazawa, Mitsuteru [1 ]
机构
[1] Tohoku Pharmaceut Univ, Fac Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9818558, Japan
[2] Teikoku Hormone Med Co Ltd, Takatsu Ku, Kanagawa 2138522, Japan
[3] Tohoku Univ, Grad Sch Med, Dept Med, Div Nephrol Endocrinol & Vasc Med,Aoba Ku, Sendai, Miyagi 9808575, Japan
关键词
aldosterone; high-performance liquid chromatography; electrospray ionization tandem mass; spectrometry; picolinyl ester; derivatization;
D O I
10.1016/j.chroma.2008.05.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive quantification method liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was investigated in a positive mode using recently developed picolinyl derivatization. Aldosterone was smoothly and quantitatively converted to the ethyl ether-picolinyl derivative by treatment with HCI-ethanol followed by the esterification with picolinic acid in the presence of 2-methyl-6-nitrobenzoic anhydride and 4-dimethylaminopyridine. The positive ion-ESI mass spectrum of the ethyl ether-picolinyl derivative was characterized by an appearance of protonated molecule ([M+H](+)) as a base peak. The ethyl ether-picolinyl derivatization gave a successful result in a separation of alclosterone from corticosterone, dehydrocorticosterone and cortexolone, and also provided an approximately 10-fold higher ESI response in the positive-LC-ESI-MS/MS (selected reaction monitoring; SRM) when compared to that of underivatized molecule (negative mode). The limit of quantification of aldosterone by SRM using ethyl ether-picolinyl derivatization (m/z 494 -- m1z 448) was 1 pg/0.2 ml serum with accuracy and precision of 92.6% and 5.6%, respectively. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [31] Determination of bulleyaconitine A in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Weng, WY
    Xu, HN
    Huang, JM
    Wang, GQ
    Shen, T
    Zhang, JF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 315 - 320
  • [32] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Kim, HY
    Chang, KY
    Lee, HJ
    Han, SB
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (01) : 109 - 114
  • [33] Determination of nitrofuran metabolites in milk by liquid chromatography-electrospray ionization tandem mass spectrometry
    Rodziewicz, Lech
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 864 (1-2): : 156 - 160
  • [34] Determination of Fatty Acids in Beef by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Soliman, Laiel C.
    Andrucson, Elizabeth M.
    Donkor, Kingsley K.
    Church, John S.
    Cinel, Bruno
    FOOD ANALYTICAL METHODS, 2016, 9 (03) : 630 - 637
  • [35] Determination of the active metabolite of sibutramine by liquid chromatography-electrospray ionization tandem mass spectrometry
    Chen, J
    Lu, W
    Zhang, QZ
    Jiang, XG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02): : 197 - 203
  • [36] Development of a sensitive liquid chromatography-electrospray ionization mass spectrometry method for the measurement of KW-5139 in rat plasma
    Yamaguchi, K
    Takashima, M
    Uchimura, T
    Kobayashi, S
    BIOMEDICAL CHROMATOGRAPHY, 2000, 14 (02) : 77 - 81
  • [38] A Pyridinium Derivatization Reagent for Highly Sensitive Detection of Poly(carboxylic acid)s Using Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Kawasue, Shimba
    Sakaguchi, Yohei
    Koga, Reiko
    Yoshida, Hideyuki
    Nohta, Hitoshi
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, : 1492 - 1498
  • [39] Simple and practical derivatization procedure for enhanced detection of carboxylic acids in liquid chromatography-electrospray ionization-tandem mass spectrometry
    Higashi, Tatsuya
    Ichikawa, Takuya
    Inagaki, Shinsuke
    Min, Jun Zhe
    Fukushima, Takeshi
    Toyo'oka, Toshimasa
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (05) : 809 - 818
  • [40] Quantification of cardiolipin by liquid chromatography-electrospray ionization mass spectrometry
    Garrett, Teresa A.
    Kordestani, Reza
    Raetz, Christian R. H.
    LIPIDOMICS AND BIOACTIVE LIPIDS: SPECIALIZED ANALYTICAL METHODS AND LIPIDS IN DISEASE, 2007, 433 : 213 - 230