Development of sensitive derivatization method for aldosterone in liquid chromatography-electrospray ionization tandem mass spectrometry of corticosteroids

被引:48
|
作者
Yamashita, Kouwa [1 ]
Okuyama, Mitsunobu [2 ]
Nakagawa, Risa [2 ]
Honma, Seijiro [2 ]
Satoh, Fumitoshi [3 ]
Morimoto, Ryo [3 ]
Ito, Sadayoshi [3 ]
Takahashi, Madoka [1 ]
Numazawa, Mitsuteru [1 ]
机构
[1] Tohoku Pharmaceut Univ, Fac Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9818558, Japan
[2] Teikoku Hormone Med Co Ltd, Takatsu Ku, Kanagawa 2138522, Japan
[3] Tohoku Univ, Grad Sch Med, Dept Med, Div Nephrol Endocrinol & Vasc Med,Aoba Ku, Sendai, Miyagi 9808575, Japan
关键词
aldosterone; high-performance liquid chromatography; electrospray ionization tandem mass; spectrometry; picolinyl ester; derivatization;
D O I
10.1016/j.chroma.2008.05.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive quantification method liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was investigated in a positive mode using recently developed picolinyl derivatization. Aldosterone was smoothly and quantitatively converted to the ethyl ether-picolinyl derivative by treatment with HCI-ethanol followed by the esterification with picolinic acid in the presence of 2-methyl-6-nitrobenzoic anhydride and 4-dimethylaminopyridine. The positive ion-ESI mass spectrum of the ethyl ether-picolinyl derivative was characterized by an appearance of protonated molecule ([M+H](+)) as a base peak. The ethyl ether-picolinyl derivatization gave a successful result in a separation of alclosterone from corticosterone, dehydrocorticosterone and cortexolone, and also provided an approximately 10-fold higher ESI response in the positive-LC-ESI-MS/MS (selected reaction monitoring; SRM) when compared to that of underivatized molecule (negative mode). The limit of quantification of aldosterone by SRM using ethyl ether-picolinyl derivatization (m/z 494 -- m1z 448) was 1 pg/0.2 ml serum with accuracy and precision of 92.6% and 5.6%, respectively. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [1] Preparation and structural elucidation of the picolinyl ester of aldosterone for liquid chromatography-electrospray ionization tandem mass spectrometry
    Yamashita, Kouwa
    Tadokoro, Yumiko
    Takahashi, Madoka
    Numazawa, Mitsuteru
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (06) : 873 - 877
  • [2] Derivatization method for sensitive determination of fluorotelomer alcohols in sediment by liquid chromatography-electrospray tandem mass spectrometry
    Peng, Hui
    Hu, Kejun
    Zhao, Fanrong
    Hu, Jianying
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1288 : 48 - 53
  • [3] Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry
    Santa, Tomofumi
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (1-2) : 1 - 10
  • [4] Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry for biomedical analysis
    Santa, Tomofumi
    Al-Dirbashi, Osama Y.
    Fukushima, Takeshi
    DRUG DISCOVERIES AND THERAPEUTICS, 2007, 1 (02) : 108 - 118
  • [5] Development of highly sensitive quantification method for testosterone and dihydrotestosterone in human serum and prostate tissue by liquid chromatography-electrospray ionization tandem mass spectrometry
    Yamashita, Kouwa
    Miyashiro, Yoshimichi
    Maekubo, Hitoe
    Okuyama, Mitsunobu
    Honma, Seijiro
    Takahashi, Madoka
    Numazawa, Mitsuteru
    STEROIDS, 2009, 74 (12) : 920 - 926
  • [6] Simple and practical derivatization procedure for enhanced detection of carboxylic acids in liquid chromatography-electrospray ionization-tandem mass spectrometry
    Higashi, Tatsuya
    Ichikawa, Takuya
    Inagaki, Shinsuke
    Min, Jun Zhe
    Fukushima, Takeshi
    Toyo'oka, Toshimasa
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (05) : 809 - 818
  • [7] Isothiocyanates as derivatization reagents for amines in liquid chromatography/electrospray ionization-tandem mass spectrometry
    Santa, Tomofumi
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 915 - 918
  • [8] 2-Hydrazino-1-methylpyridine: a highly sensitive derivatization reagent for oxosteroids in liquid chromatography-electrospray ionization-mass spectrometry
    Higashi, T
    Yamauchi, A
    Shimada, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02): : 214 - 222
  • [9] Development of a liquid chromatography-electrospray ionization tandem mass spectrometric method for the simultaneous analysis of free fatty acids
    Lee-Okada, Hyeon-Cheol
    Hama, Kotaro
    Yokoyama, Kazuaki
    Yokomizo, Takehiko
    JOURNAL OF BIOCHEMISTRY, 2021, 170 (03) : 389 - 397
  • [10] Derivatization for liquid chromatography-electrospray ionization-mass spectrometry analysis of small-molecular weight compounds
    Zhang, Tian-Yi
    Li, Sha
    Zhu, Quan-Fei
    Wang, Qing
    Hussain, Dilshad
    Feng, Yu-Qi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 119