Effect of open circuit voltage on degradation of a short proton exchange membrane fuel cell stack with bilayer membrane configurations

被引:30
作者
Zhang, Shengsheng [1 ]
Yuan, Xiao-Zi [1 ]
Hiesgen, Renate [2 ]
Friedrich, K. Andreas [3 ]
Wang, Haijiang [1 ]
Schulze, Mathias [3 ]
Haug, Andrea [3 ]
Li, Hui [1 ]
机构
[1] Natl Res Council Canada, Inst Fuel Cell Innovat, Vancouver, BC V6T 1W5, Canada
[2] Univ Appl Sci Esslingen, Dept Basic Sci, D-73728 Esslingen, Germany
[3] German Aerosp Ctr, Inst Tech Thermodynam, D-70569 Stuttgart, Germany
关键词
PEM fuel cell; Twin-CCM; Degradation; Membrane; Open circuit voltage; CATALYST LAYER DEGRADATION;
D O I
10.1016/j.jpowsour.2012.01.031
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In the present work, membrane electrode assembly degradation of a 4-cell stack with specially designed twin catalyst coated membranes (twin-CCMs) was carried out for 1600 h under open circuit voltage (OCV) conditions. Four types of membrane with various thicknesses were employed in the experiment. Each twin-CCM was composed of two membranes of the same type with a catalyst layer coated only on one side. The purpose of this special configuration was to facilitate postmortem analysis of the membrane after degradation due to the detachable membrane structure. By means of several in situ electrochemical measurements, the performance of the individual cells was analysed every 200h during the degradation process. Postmortem analyses such as scanning electron microscopy, atomic force microscopy, and infrared imaging were also conducted to identify the membrane degradation mechanisms after exposure to OCV. The results indicate that membrane degradation, which correlates with electrode degradation, is the most direct reason for the failure of the whole cell/stack during OCV operation, especially for cells with thinner membranes. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:290 / 300
页数:11
相关论文
共 24 条
[1]  
Aarhaug T.A., 2006, ECS T, V3, P775, DOI DOI 10.1149/1.2356197
[2]   Proton conductivity study of a fuel cell membrane with nanoscale resolution [J].
Aleksandrova, Elena ;
Hiesgen, Renate ;
Eberhard, Dirk ;
Friedrich, K. Andreas ;
Kaz, Till ;
Roduner, Emil .
CHEMPHYSCHEM, 2007, 8 (04) :519-522
[3]   PEM fuel cell Pt/C dissolution and deposition in nafion electrolyte [J].
Bi, Wu ;
Gray, Gary E. ;
Fuller, Thomas F. .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2007, 10 (05) :B101-B104
[4]   Degradation of polymer electrolyte membranes [J].
Collier, Amanda ;
Wang, Haijiang ;
Yuan, Xiao Zi ;
Zhang, Jiujun ;
Wilkinson, David P. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (13) :1838-1854
[5]   Instability of Pt/C electrocatalysts in proton exchange membrane fuel cells - A mechanistic investigation [J].
Ferreira, PJ ;
la O', GJ ;
Shao-Horn, Y ;
Morgan, D ;
Makharia, R ;
Kocha, S ;
Gasteiger, HA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (11) :A2256-A2271
[6]   High-resolution imaging of ion conductivity of Nafion® membranes with electrochemical atomic force microscopy [J].
Hiesgen, R. ;
Aleksandrova, E. ;
Meichsner, G. ;
Wehl, I. ;
Roduner, E. ;
Friedrich, K. A. .
ELECTROCHIMICA ACTA, 2009, 55 (02) :423-429
[7]   Nanoscale properties of polymer fuel cell materials-A selected review [J].
Hiesgen, Renate ;
Wehl, Ines ;
Aleksandrova, Elena ;
Roduner, Emil ;
Bauder, Alexander ;
Friedrich, K. Andreas .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (14) :1223-1238
[8]   In situ detection of hydrogen peroxide in PEM fuel cells [J].
Liu, W ;
Zuckerbrod, D .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (06) :A1165-A1170
[9]  
Mittal VO, 2006, ECS T, V1, P275
[10]   GAS PERMEATION IN SPE METHOD .2. OXYGEN AND HYDROGEN PERMEATION THROUGH NAFION [J].
OGUMI, Z ;
KUROE, T ;
TAKEHARA, Z .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1985, 132 (11) :2601-2605