Evaluation of the Malvern Spraytec® with inhalation cell for the measurement of particle size distribution from metered dose inhalers

被引:37
作者
Haynes, A
Shaik, MS
Krarup, H
Singh, M [1 ]
机构
[1] Florida A&M Univ, Coll Pharm & Pharmaceut Sci, Div Pharmaceut, Tallahassee, FL 32307 USA
[2] Malvern Instruments Inc, Southborough, MA 01772 USA
关键词
laser diffraction; particle size analysis; metered dose inhaler; Spraytec (R); inhalation cell;
D O I
10.1002/jps.10558
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The purpose of this study was to evaluate the Malvern Spraytec(R) with inhalation cell attachment as a means of analyzing the particle size distribution of aerosols from pressurized metered dose inhalers (pMDIs). The aerosol particle size distribution of various commercially available, placebo, and experimental pMDI formulations was determined using Spraytec(R) under various experimental conditions and the relevant data were compared with the Andersen cascade impactor data. The Spraytec(R) volume median diameter (Dv 50) values for commercial chlorofluorocarbon- and hydrofluoroalkane (HFA)-based pMDIs were respectively smaller and higher compared with their reported mass median aerodynamic diameter values. It was possible to obtain a close agreement between Spraytec(R) D-v 50 and the reported mass median aerodynamic diameter values for a solution-type pMDI formulation, Qvar 50, by equilibrating the pMDI to 55 degreesC before the measurement and using a 20-cm throat extension. Incorporation of a nonvolatile solvent propylene glycol (PG) in placebo pMDIs (15% w/w ethanol, 0.5-20.0% w/w PG in HFA 134a) showed an increase in Dv 50 with increasing concentration of PG. Furthermore, it was possible to obtain a correlation (R-2 = 0.8037) between Spraytec(R) and Andersen cascade impactor data for the experimental nimesulide-pMDI formulations containing 0.1% w/w drug, 0.25-10% w/w PG, and 15% ethanol in HFA 134a. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:349 / 363
页数:15
相关论文
共 38 条
[1]   An analysis of the Fraunhofer Diffraction method for particle size distribution analysis and its application to aerosolized sprays [J].
Annapragada, A ;
Adjei, A .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 127 (02) :219-227
[2]  
[Anonymous], 2001, NIST SPECIAL PUBLICA
[3]   Modulation of aerosol clouds produced by pressurised inhalation aerosols [J].
Brambilla, G ;
Ganderton, D ;
Garzia, R ;
Lewis, D ;
Meakin, B ;
Ventura, P .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1999, 186 (01) :53-61
[4]  
BYRON PR, 1994, RESP DRUG DELIVERY, V4, P232
[5]   Comparative study of dose delivery and cascade impaction performance of four metered-dose inhaler and spacer combinations [J].
Childers, AG ;
Cummings, RH ;
Kaufman, BD ;
Glennon, JJ ;
Kelly, EL ;
Lim, JC ;
McNally, C .
CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1996, 57 (02) :75-87
[6]   Characterization of inhalation aerosols: a critical evaluation of cascade impactor analysis and laser diffraction technique [J].
de Boer, AH ;
Gjaltema, D ;
Hagedoorn, P ;
Frijlink, HW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 249 (1-2) :219-231
[7]  
DING JY, 2000, AM ASS PHARM SCI ANN
[8]  
GUPTA A, 2002, RESP DRUG DELIVERY, V8, P659
[9]   EFFECT OF VAPOR-PRESSURE ON THE DEPOSITION PATTERN FROM SOLUTION-PHASE METERED-DOSE INHALERS [J].
HARNOR, KJ ;
PERKINS, AC ;
WASTIE, M ;
WILSON, CG ;
SIMS, EE ;
FEELY, LC ;
FARR, SJ .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1993, 95 (1-3) :111-116
[10]   Evaluation of an aerosolized selective COX-2 inhibitor as a potentiator of doxorubicin in a non-small-cell lung cancer cell line [J].
Haynes, A ;
Shaik, MS ;
Chatterjee, A ;
Singh, M .
PHARMACEUTICAL RESEARCH, 2003, 20 (09) :1485-1495