In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses

被引:26
作者
D'haese, Rani [1 ]
Vrombaut, Tom [1 ]
Roeykens, Herman [1 ]
Vandeweghe, Stefan [1 ]
机构
[1] Univ Ghent, Fac Med & Hlth Sci, Oral Hlth Sci, B-9000 Ghent, Belgium
关键词
intraoral scanning; accuracy; full-arch implant impression; digital impression; edentulous;
D O I
10.3390/jcm11030594
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the accuracy of full-arch digital impressions when compared to conventional impressions, when performed on the abutment or implant level. Methods: One resin cast with six implants and another cast with six abutments were scanned with Primescan v5.1 (PS51), Primescan v5.2 (PS52), Trios 3 (T3), and Trios 4 (T4). Additionally, conventional impressions (A) were made, poured in gypsum, and digitized using a lab scanner (IScan D104i). A coordinate machine (Atos, GOM, Braunschweig, Germany) was used to generate the reference scan of both casts. For all scans, the position of the implants was calculated and matched with the reference scan. Angular and coronal measurements per implant were considered for trueness and precision. Results: For the implant-level model, PS52 performed significantly better in terms of trueness and precision compared to all other impressions, except for the angular trueness of A (p = 0.072) and the coronal trueness of PS51 (p = 1.000). For the abutment-level model, PS52 also performed significantly better than all other impressions, except for the coronal trueness and precision of A (p = 1.000). Conclusions: Digital impressions for full-arch implant supported prostheses can be as accurate as conventional impressions, depending on the intra-oral scanner and software. Overall, abutment level impressions were more accurate compared to implant level impressions.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review [J].
Ahlholm, Pekka ;
Sipila, Kirsi ;
Vallittu, Pekka ;
Jakonen, Minna ;
Kotiranta, Ulla .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (01) :35-41
[2]   Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type [J].
Alikhasi, Marzieh ;
Siadat, Hakime ;
Nasirpour, Alireza ;
Hasanzade, Mahya .
INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
[3]   Digital vs. conventional full-arch implant impressions: a comparative study [J].
Amin, Sarah ;
Weber, Hans Peter ;
Finkelman, Matthew ;
El Rafie, Khaled ;
Kudara, Yukio ;
Papaspyridakos, Panos .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) :1360-1367
[4]   Accuracy of digital technologies for the scanning of facial, skeletal, and intraoral tissues: A systematic review [J].
Bohner, Lauren ;
Gamba, Diego Diaz ;
Hanisch, Marcel ;
Marcio, Bruno Silva ;
Tortamano Neto, Pedro ;
Lagana, Dalva Cruz ;
Sesma, Newton .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02) :246-251
[5]   The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans [J].
Cakmak, Gulce ;
Yilmaz, Hakan ;
Trevino, Alejandro ;
Kokat, Ali Murat ;
Yilmaz, Burak .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) :533-541
[6]   Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners [J].
Di Fiore, Adolfo ;
Meneghello, Roberto ;
Graiff, Lorenzo ;
Savio, Gianpaolo ;
Vigolo, Paolo ;
Monaco, Carlo ;
Stellini, Edoardo .
JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) :396-403
[7]  
Ender A, 2019, INT J COMPUT DENT, V22, P11
[8]   The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis [J].
Fluegge, Tabea ;
van der Meer, Wicher Joerd ;
Gonzalez, Beatriz Gimenez ;
Vach, Kirstin ;
Wismeijer, Daniel ;
Wang, Ping .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 :374-392
[9]   Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation [J].
Huang, Ruoxuan ;
Liu, Yuanxiang ;
Huang, Baoxin ;
Zhang, Chaobiao ;
Chen, Zhuofan ;
Li, Zhipeng .
CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) :625-633
[10]   Accuracy of full-arch digital impressions: an in vitro and in vivo comparison [J].
Keul, Christine ;
Gueth, Jan-Frederik .
CLINICAL ORAL INVESTIGATIONS, 2020, 24 (02) :735-745