Integrated automated particle tracking microfluidic enables high-throughput cell deformability cytometry for red cell disorders

被引:25
作者
Guruprasad, Puneeth [1 ,2 ]
Mannino, Robert G. [1 ,2 ,3 ]
Caruso, Christina [3 ]
Zhang, Hanqing [4 ]
Josephson, Cassandra D. [5 ]
Roback, John D. [5 ]
Lam, Wilbur A. [1 ,2 ,3 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Emory Univ, Atlanta, GA 30322 USA
[3] Emory Univ, Aflac Canc & Blood Disorder Ctr, Childrens Healthcare Atlanta, Dept Pediat,Sch Med, 412 Emory Childrens Ctr,2015 Uppergate Dr, Atlanta, GA 30322 USA
[4] Umea Univ, Dept Phys, Umea, Sweden
[5] Emory Univ, Sch Med, Dept Pathol & Lab Med, Ctr Transfus & Cellular Therapies, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
BLOOD-CELLS; ERYTHROCYTE DEFORMABILITY; FLOW-CYTOMETRY; STORAGE; TIME; MICROPARTICLES; HYDROXYUREA; DIAGNOSIS; VELOCITY; ANEMIA;
D O I
10.1002/ajh.25345
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Investigating individual red blood cells (RBCs) is critical to understanding hematologic diseases, as pathology often originates at the single-cell level. Many RBC disorders manifest in altered biophysical properties, such as deformability of RBCs. Due to limitations in current biophysical assays, there exists a need for high-throughput analysis of RBC deformability with single-cell resolution. To that end, we present a method that pairs a simple in vitro artificial microvasculature network system with an innovative MATLAB-based automated particle tracking program, allowing for high-throughput, single-cell deformability index (sDI) measurements of entire RBC populations. We apply our technology to quantify the sDI of RBCs from healthy volunteers, Sickle cell disease (SCD) patients, a transfusion-dependent beta thalassemia major patient, and in stored packed RBCs (pRBCs) that undergo storage lesion over 4 weeks. Moreover, our system can also measure cell size for each RBC, thereby enabling 2D analysis of cell deformability vs cell size with single cell resolution akin to flow cytometry. Our results demonstrate the clear existence of distinct biophysical RBC subpopulations with high interpatient variability in SCD as indicated by large magnitude skewness and kurtosis values of distribution, the "shifting" of sDI vs RBC size curves over transfusion cycles in beta thalassemia, and the appearance of low sDI RBC subpopulations within 4 days of pRBC storage. Overall, our system offers an inexpensive, convenient, and high-throughput method to gauge single RBC deformability and size for any RBC population and has the potential to aid in disease monitoring and transfusion guidelines for various RBC disorders.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 55 条
  • [1] Dynamic deformability of sickle red blood cells in microphysiological flow
    Alapan, Y.
    Matsuyama, Y.
    Little, J. A.
    Gurkan, U. A.
    [J]. TECHNOLOGY, 2016, 4 (02): : 71 - 79
  • [2] Extracellular vesicles in transfusion-related immunomodulation and the role of blood component manufacturing
    Almizraq, Ruqayyah J.
    Seghatchian, Jerard
    Acker, Jason P.
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2016, 55 (03) : 281 - 291
  • [3] Athanassiou G, 2006, CLIN HEMORHEOL MICRO, V35, P291
  • [4] EFFECT OF HYDROXYUREA ON THE RHEOLOGICAL PROPERTIES OF SICKLE ERYTHROCYTES INVIVO
    BALLAS, SK
    DOVER, GJ
    CHARACHE, S
    [J]. AMERICAN JOURNAL OF HEMATOLOGY, 1989, 32 (02) : 104 - 111
  • [5] Hemodynamic Functionality of Transfused Red Blood Cells in the Microcirculation of Blood Recipients
    Barshtein, Gregory
    Arbell, Dan
    Yedgar, Saul
    [J]. FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [6] Deformability of transfused red blood cells is a potent effector of transfusioninduced hemoglobin increment: A study with β-thalassemia major patients
    Barshtein, Gregory
    Goldschmidt, Neta
    Pries, Axel R.
    Zelig, Orly
    Arbell, Dan
    Yedgar, Saul
    [J]. AMERICAN JOURNAL OF HEMATOLOGY, 2017, 92 (09) : E559 - E560
  • [7] Deformability of transfused red blood cells is a potent determinant of transfusion-induced change in recipient's blood flow
    Barshtein, Gregory
    Pries, Axel R.
    Goldschmidt, Neta
    Zukerman, Ayelet
    Orbach, Ariel
    Zelig, Orly
    Arbell, Dan
    Yedgar, Saul
    [J]. MICROCIRCULATION, 2016, 23 (07) : 479 - 486
  • [8] Correlation between erythrocytes deformability and size: A study using a microchannel based cell analyzer
    Bransky, Avishay
    Korin, Natanel
    Nemirovski, Yael
    Dinnar, Uri
    [J]. MICROVASCULAR RESEARCH, 2007, 73 (01) : 7 - 13
  • [9] Assessment of the flow velocity of blood cells in a microfluidic device using joint spectral and time domain optical coherence tomography
    Bukowska, Danuta M.
    Derzsi, Ladislav
    Tamborski, Szymon
    Szkulmowski, Maciej
    Garstecki, Piotr
    Wojtkowski, Maciej
    [J]. OPTICS EXPRESS, 2013, 21 (20): : 24025 - 24038
  • [10] Chen Y, 2018, BIOMICROFLUIDICS, V12