During time-critical brain surgery, the detection of developing cerebral ischemia is particularly important because early therapeutic intervention may reduce the mortality of the patient. The purpose of this system is to provide an efficient means of remote teleconsultation for the early detection of ischemia, particularly when subspecialists are unavailable. The hardware and software design architecture for the multimedia brain function teleconsultation system including the dedicated brain function monitoring system is described. In order to comprehensively support remote teleconsultation, multi-media resources needed for ischemia interpretation were included: EEG signals, CSA, CD-CSA, radiological images, surgical microscope video images and video conferencing. PC-based system integration with standard interfaces and the operability over the Ethernet meet the cost-effectiveness while the modular software was customized with a diverse range of data manipulations and control functions necessary for shared workspace and standard interfaces. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 17 条
  • [1] AHMED K, 1990, IEEE J SAC, V8, P325
  • [2] *AM COLL RAD NAT E, 1993, DIG IM COMM MED DICO
  • [3] Multimedia a systems for telemedicine and their communications requirements
    Cabral, JE
    Kim, YM
    [J]. IEEE COMMUNICATIONS MAGAZINE, 1996, 34 (07) : 20 - 27
  • [4] Gusev E I, 1985, Neurosci Behav Physiol, V15, P144, DOI 10.1007/BF01186982
  • [5] Gusev E I, 1989, Neurosci Behav Physiol, V19, P51, DOI 10.1007/BF01148411
  • [6] Kleinholz L., 1994, IEEE Multimedia, V1, P44, DOI 10.1109/93.338686
  • [7] KRUGLINSKI DJ, 1995, INSIDE VISUAL C PLUS
  • [8] BALLOON TEST OCCLUSION OF THE INTERNAL CAROTID-ARTERY WITH MONITORING OF COMPRESSED SPECTRAL ARRAYS (CSAS) OF ELECTROENCEPHALOGRAM
    MORIOKA, T
    MATSUSHIMA, T
    FUJII, K
    FUKUI, M
    HASUO, K
    HISASHI, K
    [J]. ACTA NEUROCHIRURGICA, 1989, 101 (1-2) : 29 - 34
  • [9] A MULTIMEDIA INTERHOSPITAL COMMUNICATIONS-SYSTEM FOR MEDICAL CONSULTATIONS
    OROZCOBARBOSA, L
    KARMOUCH, A
    GEORGANAS, ND
    GOLDBERG, M
    [J]. IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 1992, 10 (07) : 1145 - 1157
  • [10] ORPHANOS G, 1993, SPIE PACS DESIGN EVA, V1899, P476