Image resolution and magnification using a cone beam densitometer: optimizing data acquisition for hip morphometric analysis

被引:24
作者
Boudousq, V
Goulart, DM
Dinten, JM
de Kerleau, CC
Thomas, E
Mares, O
Kotzki, PO
机构
[1] CHU Nimes, Hop Caremeau, Serv Med Nucl & Biophys, F-30900 Nimes, France
[2] CEA Grenoble, Dept Syst Informat & Sante, LETI, Direct Rech Technol, F-38054 Grenoble, France
[3] CHU Nimes, Hop Caremeau, Serv Informat Med, F-30900 Nimes, France
关键词
cone beam; DXA; magnification; resolution;
D O I
10.1007/s00198-004-1751-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone mineral density (BMD) is a primary determinant of hip fracture risk. However, other factors, notably the femoral geometry, can influence hip fracture risk. The purpose of this study was to evaluate the potential of a new cone beam densitometer, the DMS Lexxos, in order to visualise femoral morphometry. Resolution, magnification and distortion were assessed in vitro using a line pair test pattern and a matrix test object. Results were given in comparison with currently available systems: the Hologic Discovery A and the Lunar Prodigy densitometers. The DMS Lexxos image resolution was the same in the longitudinal and transversal directions evaluated between 1.4 and 0.5 line pairs/mm (lps/mm) for an attenuation varying from 25 to 325 mm of Perplex. The longitudinal resolution was evaluated between 0.9 and 0.5 lps/mm with the Hologic Discovery densitometer, and inferior to 0.5 with the Lunar Prodigy; as for transversal resolution, it varied from 0.63 to 0.5 lps/mm and from 0.6 to inferior 0.5 lps/mm, respectively. The image was isotropic without magnification with the GE-Lunar Prodigy, whereas there was only a transversal magnification with the Hologic Discovery device. The magnification was about 1.17% cm(-1) supercript stopin the two directions, while increasing the distance of the phantom above the examination table with the Lexxos. This magnification was isotropic without distortion. The magnification could be evaluated from two images taken before and after translation of the C-arm, and a magnification correction could be applied. This method was applied to a phantom and to a human cadaver femoral bone.
引用
收藏
页码:813 / 822
页数:10
相关论文
共 19 条
  • [1] Femoral bone mineral density, neck-shaft angle and mean femoral neck width as predictors of hip fracture in men and women
    Alonso, CG
    Curiel, MD
    Carranza, FH
    Cano, RP
    Pérez, AD
    [J]. OSTEOPOROSIS INTERNATIONAL, 2000, 11 (08) : 714 - 720
  • [2] Comparison of two Hologic DXA systems (QDR 1000 and QDR 4500/A)
    Barthe, N
    Braillon, P
    Ducassou, D
    BasseCathalinat, B
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (835) : 728 - 739
  • [3] Hip fracture risk and proximal femur geometry from DXA scans
    Bergot, C
    Bousson, V
    Meunier, A
    Laval-Jeantet, M
    Laredo, JD
    [J]. OSTEOPOROSIS INTERNATIONAL, 2002, 13 (07) : 542 - 550
  • [4] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) : 902 - 906
  • [5] CODY DD, 1993, P 39 ANN M ORTH RES, P19
  • [6] CUMMINGS SR, 1990, JAMA-J AM MED ASSOC, V263, P655
  • [7] Dual-energy X-rays absorptiometry using a 2D digital radiography detector. Application to bone densitometry
    Dinten, JM
    Robert-Coutant, C
    Darboux, M
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 459 - 468
  • [8] FAULKNER KG, 1994, J BONE MINER RES, V9, P1065
  • [9] BILATERAL COMPARISON OF FEMORAL BONE-DENSITY AND HIP AXIS LENGTH FROM SINGLE AND FAN-BEAM DXA SCANS
    FAULKNER, KG
    GENANT, HK
    MCCLUNG, M
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 26 - 31
  • [10] SIMPLE MEASUREMENT OF FEMORAL GEOMETRY PREDICTS HIP FRACTURE - THE STUDY OF OSTEOPOROTIC FRACTURES
    FAULKNER, KG
    CUMMINGS, SR
    BLACK, D
    PALERMO, L
    GLUER, CC
    GENANT, HK
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 (10) : 1211 - 1217