Anatomic and pathological characterization of choroidal melanoma using multimodal imaging: what is practical, what is needed?

被引:12
作者
Lindner, Tobias [1 ]
Langner, Soenke [6 ]
Falke, Karen [2 ]
Walter, Uwe [3 ]
Krueger, Paul-Christian [6 ]
Pohlmann, Andreas [7 ]
Zimpfer, Annette [4 ]
Stahnke, Thomas [2 ]
Hadlich, Stefan [6 ]
Guthoff, Rudolf [5 ,7 ]
Erbersdobler, Andreas [4 ]
Niendorf, Thoralf [7 ]
Stachs, Oliver [2 ]
机构
[1] Univ Med Rostock, Core Facil Small Anim Imaging, D-18057 Rostock, Germany
[2] Univ Med Rostock, Dept Ophthalmol, D-18057 Rostock, Germany
[3] Univ Med Rostock, Dept Neurol, D-18057 Rostock, Germany
[4] Univ Med Rostock, Inst Pathol, D-18057 Rostock, Germany
[5] Univ Med Rostock, Inst Biomed Engn, D-18057 Rostock, Germany
[6] Univ Med Greifswald, Inst Diagnost Radiol & Neuroradiol, Greifswald, Germany
[7] Max Delbruck Ctr Mol Med, BUFF, Berlin, Germany
关键词
choroidal melanoma; histology; magnetic resonance imaging; multimodal imaging; ultrasound; FIELD MAGNETIC-RESONANCE; UVEAL MELANOMA; HUMAN EYE; MR MICROSCOPY; 7.0; TESLA; 7; T; DIAGNOSIS; THERAPY; MASSES; ARRAY;
D O I
10.1097/CMR.0000000000000156
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Choroidal melanoma is the most frequently occurring intraocular tumor in adults. The aim of this work is to assess the potential of state-of-the art in-vivo and ex-vivo imaging modalities for the characterization of choroidal melanoma. Multimodal imaging of a choroidal melanoma was performed in a 53-year-old male patient. In-vivo ophthalmoscopy, ultrasound microscopy, duplex ultrasound, and 7.0 T MRI were performed. Ex-vivo examination of the enucleated eye included 7.0 and 9.4 T magnetic resonance microscopy as well as histopathology with hematoxylin and eosin staining. Imaging of choroidal melanoma with ultrahigh field MRI and duplex sonography provides detailed morphologic and functional information of the eye. High-spatial-resolution MRI at 9.4 T shows details of the internal texture of melanoma and other structures of the eye with an in-plane spatial resolution of 32 mu m. Ultrahigh field in-vivo MRI at 7.0 T and ex-vivo MRI at 7.0 and 9.4 T correlate well with histologic evaluation. In-vivo ultrahigh field MRI is an emerging technique for the characterization and staging of ocular tumors. The combination of in-vivo ultrahigh-field MRI and duplex sonography has the potential to complement or even substitute complex and invasive biopsies. Copyright (C) 2015 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 35 条
[1]  
[Anonymous], INF MAN SEEK MARK CL
[2]   High-resolution MRI of uveal melanoma using a microcoil phased array at 7 T [J].
Beenakker, J. W. M. ;
van Rijn, G. A. ;
Luyten, G. P. M. ;
Webb, A. G. .
NMR IN BIOMEDICINE, 2013, 26 (12) :1864-1869
[3]   Magnetic resonance angiography visualization of abnormal tumor vasculature in genetically engineered mice [J].
Brubaker, LM ;
Bullitt, E ;
Yin, CY ;
Van Dyke, T ;
Lin, WL .
CANCER RESEARCH, 2005, 65 (18) :8218-8223
[4]  
Committee to Assess the Current Status and Future Direction of High Magnetic Field Science in the United States
[5]  
Board on Physics and Astronomy
[6]  
Division on Engineering and Physical Sciences
[7]  
National Research Council, 2013, HIGH MAGN FIELD SCI
[8]   Experimental Differentiation of Intraocular Masses Using Ultrahigh-Field Magnetic Resonance Imaging - A Case Series [J].
Falke, Karen ;
Krueger, Paul ;
Hosten, Norbert ;
Zimpfer, Annette ;
Guthoff, Rudolf ;
Langner, Soenke ;
Stachs, Oliver .
PLOS ONE, 2013, 8 (12)
[9]   Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla [J].
Frauenrath, Tobias ;
Hezel, Fabian ;
Renz, Wolfgang ;
d'Orth, Thibaut de Geyer ;
Dieringer, Matthias ;
von Knobelsdorff-Brenkenhoff, Florian ;
Prothmann, Marcel ;
Schulz-Menger, Jeanette ;
Niendorf, Thoralf .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
[10]   Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope [J].
Frauenrath, Tobias ;
Hezel, Fabian ;
Heinrichs, Uwe ;
Kozerke, Sebastian ;
Utting, Jane F. ;
Kob, Malte ;
Butenweg, Christoph ;
Boesiger, Peter ;
Niendorf, Thoralf .
INVESTIGATIVE RADIOLOGY, 2009, 44 (09) :539-547