Application of ratiometric fluorescence sensor-based microwave-assisted synthesized CdTe quantum dots and mesoporous structured epitope-imprinted polymers for highly efficient determination of tyrosine phosphopeptide

被引:21
作者
Amiri, Nasibeh Saeedzadeh [1 ]
Hosseini, Mohammad-Reza Milani [1 ]
机构
[1] Iran Univ Sci & Technol, Res Lab Real Samples Anal, Dept Analyt Chem, Fac Chem, Tehran, Iran
关键词
EXCHANGE CHROMATOGRAPHY; SELECTIVE ENRICHMENT; SENSITIVE DETECTION; OPTIMIZATION; SURFACE; BIOSENSOR; COMPOSITE; PHOSPHOPROTEOMICS; PROBE;
D O I
10.1039/c9ay00276f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Molecularly imprinted polymer-coated quantum dots (MIP@QDs) as fluorescent sensors modified with ratiometric fluorescence techniques and mesoporous structured epitope-imprinted silica materials (QDs@SiO2@EMSiO2) were fabricated and applied for the detection of tyrosine phosphopeptide (pTyr) for the first time. The probe exhibited dual-emission peaks at 520 and 625 nm under the single excitation wavelength of 400 nm. The pTyr molecules could selectively quench the QDs, which had red emission, but the intensity of the QDs with green emission did not change; thus, it was considered as an internal reference. These phenomena caused a discernible change in the fluorescence color from orange to green under a UV lamp. In this work, phenylphosphonic acid and 1-tetradecyl-3-methylimidazolium chloride were utilized as the template molecule and template for mesoporous silica, respectively. 1-Propyltrimethoxysilane-3-methylimidazolium chloride was applied as the functional monomer and 3-aminopropyltriethoxysilane was employed as the cross-linker. Meanwhile, the conventional heating technique, namely, hydrothermal synthesis was substituted with the microwave heating method, resulting in fast, uniform and controllable nucleation and growth of the nanoparticles. The suggested epitope-imprinted polymer-coated mesoporous structured fluorescence composite compared with the non-mesoporous structured composite and single-emission MIP biosensor demonstrated excellent efficiency. Under the optimum conditions, the linear range and the detection limit obtained were 0.07-230 mu M and 34 nM, respectively. Besides, the suggested nano-biosensor depicted highly reproducible results in the probing of real samples, with recoveries between 95.85% and 103.23%.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 43 条
[1]   Beyond labels: A review of the application of quantum dots as integrated components of assays, bioprobes, and biosensors utilizing optical transduction [J].
Algar, W. Russ ;
Tavares, Anthony J. ;
Krull, Ulrich J. .
ANALYTICA CHIMICA ACTA, 2010, 673 (01) :1-25
[2]   Anion-Exchange Chromatography of Phosphopeptides: Weak Anion Exchange versus Strong Anion Exchange and Anion-Exchange Chromatography versus Electrostatic Repulsion-Hydrophilic Interaction Chromatography [J].
Alpert, Andrew J. ;
Hudecz, Otto ;
Mechtler, Karl .
ANALYTICAL CHEMISTRY, 2015, 87 (09) :4704-4711
[3]  
Baaske MD, 2014, NAT NANOTECHNOL, V9, P933, DOI [10.1038/nnano.2014.180, 10.1038/NNANO.2014.180]
[4]   Large-scale characterization of HeLa cell nuclear phosphoproteins [J].
Beausoleil, SA ;
Jedrychowski, M ;
Schwartz, D ;
Elias, JE ;
Villén, J ;
Li, JX ;
Cohn, MA ;
Cantley, LC ;
Gygi, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (33) :12130-12135
[5]   In-depth Qualitative and Quantitative Profiling of Tyrosine Phosphorylation Using a Combination of Phosphopeptide Immunoaffinity Purification and Stable Isotope Dimethyl Labeling [J].
Boersema, Paul J. ;
Foong, Leong Yan ;
Ding, Vanessa M. Y. ;
Lemeer, Simone ;
van Breukelen, Bas ;
Philp, Robin ;
Boekhorst, Jos ;
Snel, Berend ;
den Hertog, Jeroen ;
Choo, Andre B. H. ;
Heck, Albert J. R. .
MOLECULAR & CELLULAR PROTEOMICS, 2010, 9 (01) :84-99
[6]   β-Elimination coupled with strong cation-exchange chromatography for phosphopeptide analysis [J].
Buncherd, Hansuk ;
Roseboom, Winfried ;
Chokchaichamnankit, Daranee ;
Sawangareetrakul, Phannee ;
Phongdara, Amornrat ;
Srisomsap, Chantragan ;
de Jong, Luitzen ;
Svasti, Jisnuson .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (14) :1695-1704
[7]   Rapid microwave-assisted synthesis of molecularly imprinted polymers on carbon quantum dots for fluorescent sensing of tetracycline in milk [J].
Hou, Juan ;
Li, Huiyu ;
Wang, Long ;
Zhang, Ping ;
Zhou, Tianyu ;
Ding, Hong ;
Ding, Lan .
TALANTA, 2016, 146 :34-40
[8]   (CdSe)ZnS quantum dots and organophosphorus hydrolase bioconjugate as biosensors for detection of paraoxon [J].
Ji, XJ ;
Zheng, JY ;
Xu, JM ;
Rastogi, VK ;
Cheng, TC ;
DeFrank, JJ ;
Leblanc, RM .
JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (09) :3793-3799
[9]   RETRACTED: L-Cysteine-capped ZnS quantum dots based fluorescence sensor for Cu2+ ion (Retracted Article) [J].
Koneswaran, Masilamany ;
Narayanaswamy, Ramaier .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) :104-109
[10]  
Kui Zhong, 2010, Carbohydrate Polymers, V80, P19