Shear wave elastography can assess the in-vivo nonlinear mechanical behavior of heel-pad

被引:21
作者
Chatzistergos, Panagiotis E. [1 ]
Behforootan, Sara [2 ]
Allan, David [1 ]
Naemi, Roozbeh [1 ]
Chockalingam, Nachiappan [1 ]
机构
[1] Staffordshire Univ, Sch Life Sci & Educ, Stoke On Trent, Staffs, England
[2] Imperial Coll London, Dept Surg & Canc, London SW7 2AZ, England
关键词
Soft tissue; Acoustoelasticity; Validation; Ultrasound; Mechanical testing; Finite element; PLANTAR SOFT-TISSUE; CLINICAL-APPLICATIONS; ELASTICITY; PHANTOM; FOOT; VALIDATION; STIFFNESS; MODULUS; PAIN;
D O I
10.1016/j.jbiomech.2018.09.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study combines non-invasive mechanical testing with finite element (FE) modelling to assess for the first time the reliability of shear wave (SW) elastography for the quantitative assessment of the in-vivo nonlinear mechanical behavior of heel-pad. The heel-pads of five volunteers were compressed using a custom-made ultrasound indentation device. Tissue deformation was assessed from B-mode ultrasound and force was measured using a load cell to calculate the force - deformation graph of the indentation test. These results were used to design subject specific FE models and to inverse engineer the tissue's hyperelastic material coefficients and its stress - strain behavior. SW speed was measured for different levels of compression (from 0% to 50% compression). SW speed for 0% compression was used to assess the initial stiffness of heel-pad (i.e. initial shear modulus, initial Young's modulus). Changes in SW speed with increasing compressive loading were used to quantify the tissue's nonlinear mechanical behavior based on the theory of acoustoelasticity. Statistical analysis of results showed significant correlation between SW-based and FE-based estimations of initial stiffness, but SW underestimated initial shear modulus by 64%(+/- 16). A linear relationship was found between the SW-based and FE-based estimations of nonlinear behavior. The results of this study indicate that SW elastography is capable of reliably assessing differences in stiffness, but the absolute values of stiffness should be used with caution. Measuring changes in SW speed for different magnitudes of compression enables the quantification of the tissue's nonlinear behavior which can significantly enhance the diagnostic value of SW elastography. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 32 条
  • [1] Subject-specific finite element modelling of the human foot complex during walking: sensitivity analysis of material properties, boundary and loading conditions
    Akrami, Mohammad
    Qian, Zhihui
    Zou, Zhemin
    Howard, David
    Nester, Chris J.
    Ren, Lei
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2018, 17 (02) : 559 - 576
  • [2] Application of Acoustoelasticity to Evaluate Nonlinear Modulus in Ex Vivo Kidneys
    Aristizabal, Sara
    Carrascal, Carolina Amador
    Nenadic, Ivan Z.
    Greenleaf, James F.
    Urban, Matthew W.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (02) : 188 - 200
  • [3] Passive stiffness of monoarticular lower leg muscles is influenced by knee joint angle
    Ates, Filiz
    Andrade, Ricardo J.
    Freitas, Sandro R.
    Hug, Francois
    Lacourpaille, Lilian
    Gross, Raphael
    Yucesoy, Can A.
    Nordez, Antoine
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2018, 118 (03) : 585 - 593
  • [4] A Simulation of the Viscoelastic Behaviour of Heel Pad During Weight-Bearing Activities of Daily Living
    Behforootan, Sara
    Chatzistergos, Panagiotis E.
    Chockalingam, Nachiappan
    Naemi, Roozbeh
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (12) : 2750 - 2761
  • [5] A clinically applicable non-invasive method to quantitatively assess the visco-hyperelastic properties of human heel pad, implications for assessing the risk of mechanical trauma
    Behforootan, Sara
    Chatzistergos, Panagiotis E.
    Chockalingam, Nachiappan
    Naemi, Roozbeh
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 68 : 287 - 295
  • [6] Finite element modelling of the foot for clinical application: A systematic review
    Behforootan, Sara
    Chatzistergos, Panagiotis
    Naemi, Roozbeh
    Chockalingam, Nachiappan
    [J]. MEDICAL ENGINEERING & PHYSICS, 2017, 39 : 1 - 11
  • [7] Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    Bercoff, J
    Tanter, M
    Fink, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) : 396 - 409
  • [8] In Vivo Quantification of the Nonlinear Shear Modulus in Breast Lesions: Feasibility Study
    Bernal, Miguel
    Chamming's, Foucauld
    Couade, Mathieu
    Bercoff, Jeremy
    Tanter, Mickael
    Gennisson, Jean-Luc
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) : 101 - 109
  • [9] Three-dimensional morphology of heel fat pad: an in vivo computed tomography study
    Campanelli, Valentina
    Fantini, Massimiliano
    Faccioli, Niccolo
    Cangemi, Alessio
    Pozzo, Antonio
    Sbarbati, Andrea
    [J]. JOURNAL OF ANATOMY, 2011, 219 (05) : 622 - 631
  • [10] A Comparative Study of Strain and Shear-Wave Elastography in an Elasticity Phantom
    Carlsen, Jonathan F.
    Pedersen, Malene R.
    Ewertsen, Caroline
    Saftoiu, Adrian
    Lonn, Lars
    Rafaelsen, Soren R.
    Nielsen, Michael B.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : W236 - W242