Rapid and comprehensive monoclonal antibody Characterization using microfluidic CE-MS

被引:19
|
作者
Cao, Li [1 ]
Fabry, Daniel [1 ]
Lan, Kevin [1 ]
机构
[1] GlaxoSmithKline, CMC Analyt, 1250 S Collegeville Rd,UP 1400, Collegeville, PA 19426 USA
关键词
monoclonal antibody (mAb); microfluidic CE-MS; peptide mapping; native intact analysis; post-translation modifications (PTMs); charge variants; CATION-EXCHANGE CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; MASS-SPECTROMETRY; CHARGE VARIANTS; SEPARATION; QUALITY; OXIDATION; PEPTIDES; PART;
D O I
10.1016/j.jpba.2021.114251
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The identification and control of monoclonal antibody (mAb) critical quality attributes (CQAs) is a key component of quality by design (QbD). In this work, rapid peptide mapping and native intact charge variants analysis have been developed to comprehensively characterize and monitor mAb CQAs using a microfluidic capillary electrophoresis -mass spectrometry (CE-MS) platform. The ultrafast peptide mapping simultaneously analyzed multiple CQAs, including protein primary structure, oxidation, deamidation, succinimide, C-terminal lysine (Lys) clipping, N-terminal cyclization, and glycosylation. The microfluidic CE-MS based peptide mapping acquired results comparable to conventional but lengthy liquid chromatography - MS (LC-MS) based approach. The native intact analysis resolved mAb charge variants with a comparable resolution as commonly achieved using capillary isoelectric focusing (cIEF). Charge variants' identities were assigned based on characteristic mass shifts, knowledge learned from peptide mapping, and changes in electrophoretic mobility. Major mAb glycoforms of each charge variants were resolved and identified in the deconvoluted mass spectra. Furthermore, a model simulation was performed to reconstruct intact deconvoluted mass spectra using peptide mapping results. The reconstructed and experimentally determined intact deconvoluted mass spectra were highly correlated, suggesting that our data collected at the peptide level and intact level were consistent and highly comparable. Overall, the microfluidic CE-MS based peptide mapping and native intact charge variants analysis are high-throughput methods that have great potential to support biopharmaceutical development. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] CHED 253-Monitoring metabolism changes in Escherichia coli during amino acid starvation using CE-MS
    Hightower, G. Aaron
    Traxler, Matt
    Conway, Tyrrell
    Smith, Joel T.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 235
  • [42] Novel CE-MS technique for detection of high explosives using perfluorooctanoic acid as a MEKC and mass spectrometric complexation reagent
    Brensinger, Karen
    Rollman, Christopher
    Copper, Christine
    Genzman, Ashton
    Rine, Jacqueline
    Lurie, Ira
    Moini, Mehdi
    FORENSIC SCIENCE INTERNATIONAL, 2016, 258 : 74 - 79
  • [43] On-line CE-MS using pressurized liquid junction nanoflow electrospray interface and surface-coated capillaries
    Fanali, Salvatore
    D'Orazio, Giovanni
    Foret, Frantisek
    Kleparnik, Karel
    Aturki, Zeineb
    ELECTROPHORESIS, 2006, 27 (23) : 4666 - 4673
  • [44] Rapid characterization of monoclonal antibodies using the piezoelectric immunosensor
    Pohanka, Miroslav
    Pavlis, Oto
    Skladal, Petr
    SENSORS, 2007, 7 (03) : 341 - 353
  • [45] A rapid cIEF-ESI-MS/MS method for host cell protein analysis of a recombinant human monoclonal antibody
    Zhu, Guijie
    Sun, Liangliang
    Wojcik, Roza
    Kernaghan, Dawn
    McGivney, James B.
    Dovichi, Norman J.
    TALANTA, 2012, 98 : 253 - 256
  • [46] Rapid Assessment of Molecular Similarity between a Candidate Biosimilar and an Innovator Monoclonal Antibody Using Complementary LC-MS Methods
    Gilar, Martin
    Xie, Hongwei
    Chakraborty, Asish
    Ahn, Joomi
    Yu, Ying Qing
    Dakshinamoorthy, Deepalakshmi P.
    Chen, Weibin
    Skilton, St John
    Mazzeo, Jeffery R.
    BIOPHARM INTERNATIONAL, 2010, : 16 - 21
  • [47] The rapid quantification and detection of nitrifying bacteria by using monoclonal antibody method
    Ikuta, H
    Noda, N
    Ebie, Y
    Hirata, A
    Tsuneda, S
    Matsumura, M
    Inamori, Y
    WATER SCIENCE AND TECHNOLOGY, 2000, 42 (3-4) : 1 - 7
  • [48] Immunological rapid urease test using monoclonal antibody for Helicobacter pylori
    Nakata, H
    Itoh, H
    Ishiguchi, T
    Iwata, T
    Sato, H
    Higashimoto, Y
    Fujimoto, H
    Ichinose, M
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2004, 19 (09) : 970 - 974
  • [49] RAPID DIAGNOSIS OF WHOOPING-COUGH USING MONOCLONAL-ANTIBODY
    BORELAND, PC
    GILLESPIE, SH
    ASHWORTH, LAE
    JOURNAL OF CLINICAL PATHOLOGY, 1988, 41 (05) : 573 - 575
  • [50] Determination of monoclonal antibody production in cell culture using novel microfluidic and traditional assays
    Ohashi, R
    Otero, JM
    Chwistek, A
    Hamel, JFP
    ELECTROPHORESIS, 2002, 23 (20) : 3623 - 3629