Rapid and comprehensive monoclonal antibody Characterization using microfluidic CE-MS

被引:19
|
作者
Cao, Li [1 ]
Fabry, Daniel [1 ]
Lan, Kevin [1 ]
机构
[1] GlaxoSmithKline, CMC Analyt, 1250 S Collegeville Rd,UP 1400, Collegeville, PA 19426 USA
关键词
monoclonal antibody (mAb); microfluidic CE-MS; peptide mapping; native intact analysis; post-translation modifications (PTMs); charge variants; CATION-EXCHANGE CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; MASS-SPECTROMETRY; CHARGE VARIANTS; SEPARATION; QUALITY; OXIDATION; PEPTIDES; PART;
D O I
10.1016/j.jpba.2021.114251
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The identification and control of monoclonal antibody (mAb) critical quality attributes (CQAs) is a key component of quality by design (QbD). In this work, rapid peptide mapping and native intact charge variants analysis have been developed to comprehensively characterize and monitor mAb CQAs using a microfluidic capillary electrophoresis -mass spectrometry (CE-MS) platform. The ultrafast peptide mapping simultaneously analyzed multiple CQAs, including protein primary structure, oxidation, deamidation, succinimide, C-terminal lysine (Lys) clipping, N-terminal cyclization, and glycosylation. The microfluidic CE-MS based peptide mapping acquired results comparable to conventional but lengthy liquid chromatography - MS (LC-MS) based approach. The native intact analysis resolved mAb charge variants with a comparable resolution as commonly achieved using capillary isoelectric focusing (cIEF). Charge variants' identities were assigned based on characteristic mass shifts, knowledge learned from peptide mapping, and changes in electrophoretic mobility. Major mAb glycoforms of each charge variants were resolved and identified in the deconvoluted mass spectra. Furthermore, a model simulation was performed to reconstruct intact deconvoluted mass spectra using peptide mapping results. The reconstructed and experimentally determined intact deconvoluted mass spectra were highly correlated, suggesting that our data collected at the peptide level and intact level were consistent and highly comparable. Overall, the microfluidic CE-MS based peptide mapping and native intact charge variants analysis are high-throughput methods that have great potential to support biopharmaceutical development. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] In vivo deamidation characterization of monoclonal antibody by LC/MS/MS
    Huang, LH
    Li, JR
    Wroblewski, VJ
    Beals, JM
    Riggin, RM
    ANALYTICAL CHEMISTRY, 2005, 77 (05) : 1432 - 1439
  • [22] Fractionation and characterization of sialyl linkage isomers of serum N-glycans by CE-MS
    Zhou, Xiaomei
    Song, Woran
    Novotny, Milos V.
    Jacobson, Stephen C.
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (17) : 3348 - +
  • [23] Identifying bacterial species using CE-MS and SEQUEST with an empirical scoring function
    Hu, Anren
    Lo, Alan A. -L.
    Chen, Cheng-Tung
    Lin, Kuo-Chih
    Ho, Yen-Peng
    ELECTROPHORESIS, 2007, 28 (09) : 1387 - 1392
  • [24] Separation, identification and quantification of associated impurities in cobratide using sheathless CE-MS and CE-UV
    Liu, Bo
    Wang, Wentao
    Gao, Tie
    Huang, Lu
    Fan, Huihong
    Chen, Hong-Xu
    ANALYTICAL METHODS, 2021, 13 (34) : 3845 - 3851
  • [25] The analysis of basic and acidic compounds using non-aqueous CE and non-aqueous CE-MS
    Senior, J
    Rolland, D
    Tolson, D
    Chantzis, S
    De Biasi, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (03) : 413 - 421
  • [26] Metabolic profiling of human urine by CE-MS using a positively charged capillary coating and comparison with UPLC-MS
    Ramautar, Rawi
    Nevedomskaya, Ekaterina
    Mayboroda, Oleg A.
    Deelder, Andre M.
    Wilson, Ian D.
    Gika, Helen G.
    Theodoridis, Georgios A.
    Somsen, Govert W.
    de Jong, Gerhardus J.
    MOLECULAR BIOSYSTEMS, 2011, 7 (01) : 194 - 199
  • [27] Sensitive CE-MS analysis of potentially genotoxic alkylation compounds using derivatization and electrokinetic injection
    van Wijk, A. M.
    Niederlander, H. A. G.
    van Ogten, M. D.
    de Jong, G. J.
    ANALYTICA CHIMICA ACTA, 2015, 874 : 75 - 83
  • [28] Characterization of recombinant monoclonal antibody charge variants using WCX chromatography, icIEF and LC-MS/MS
    Liu, Hailong
    Ren, Weicheng
    Zong, Li
    Zhang, Jinliang
    Wang, Yingwu
    ANALYTICAL BIOCHEMISTRY, 2019, 564 : 1 - 12
  • [29] Comprehensive Molecular Characterization of a Cisplatin-Specific Monoclonal Antibody
    Ruhe, Lena
    Ickert, Stefanie
    Hochkirch, Ulrike
    Hofmann, Johanna
    Beck, Sebastian
    Thomale, Juergen
    Linscheid, Michael W.
    MOLECULAR PHARMACEUTICS, 2017, 14 (12) : 4454 - 4461
  • [30] Complete and rapid peptide and glycopeptide mapping of mouse monoclonal antibody by LC/MS/MS using ion trap mass spectrometry
    Hirayama, K
    Yuji, R
    Yamada, N
    Kato, K
    Arata, Y
    Shimada, I
    ANALYTICAL CHEMISTRY, 1998, 70 (13) : 2718 - 2725