Rapid and comprehensive monoclonal antibody Characterization using microfluidic CE-MS

被引:19
|
作者
Cao, Li [1 ]
Fabry, Daniel [1 ]
Lan, Kevin [1 ]
机构
[1] GlaxoSmithKline, CMC Analyt, 1250 S Collegeville Rd,UP 1400, Collegeville, PA 19426 USA
关键词
monoclonal antibody (mAb); microfluidic CE-MS; peptide mapping; native intact analysis; post-translation modifications (PTMs); charge variants; CATION-EXCHANGE CHROMATOGRAPHY; CAPILLARY-ELECTROPHORESIS; MASS-SPECTROMETRY; CHARGE VARIANTS; SEPARATION; QUALITY; OXIDATION; PEPTIDES; PART;
D O I
10.1016/j.jpba.2021.114251
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The identification and control of monoclonal antibody (mAb) critical quality attributes (CQAs) is a key component of quality by design (QbD). In this work, rapid peptide mapping and native intact charge variants analysis have been developed to comprehensively characterize and monitor mAb CQAs using a microfluidic capillary electrophoresis -mass spectrometry (CE-MS) platform. The ultrafast peptide mapping simultaneously analyzed multiple CQAs, including protein primary structure, oxidation, deamidation, succinimide, C-terminal lysine (Lys) clipping, N-terminal cyclization, and glycosylation. The microfluidic CE-MS based peptide mapping acquired results comparable to conventional but lengthy liquid chromatography - MS (LC-MS) based approach. The native intact analysis resolved mAb charge variants with a comparable resolution as commonly achieved using capillary isoelectric focusing (cIEF). Charge variants' identities were assigned based on characteristic mass shifts, knowledge learned from peptide mapping, and changes in electrophoretic mobility. Major mAb glycoforms of each charge variants were resolved and identified in the deconvoluted mass spectra. Furthermore, a model simulation was performed to reconstruct intact deconvoluted mass spectra using peptide mapping results. The reconstructed and experimentally determined intact deconvoluted mass spectra were highly correlated, suggesting that our data collected at the peptide level and intact level were consistent and highly comparable. Overall, the microfluidic CE-MS based peptide mapping and native intact charge variants analysis are high-throughput methods that have great potential to support biopharmaceutical development. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Characterization of monoclonal antibodies and antibody drug conjugates using microfluidic CE-MS technology
    Redman, Erin
    Guerrette, Joshua
    Mellors, John
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [2] CE-MS and CE-MS/MS for the multiattribute analysis of monoclonal antibody variants at the subunit level
    Schairer, Jasmin
    Roemer, Jennifer
    Neusuess, Christian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 252
  • [3] Intact NIST monoclonal antibody characterization-Proteoforms, glycoforms-Using CE-MS and CE-LIF
    Chen, Chien-Hsun
    Feng, Huatao
    Guo, Rui
    Li, Pingjing
    Laserna, Anna Karen C.
    Ji, Ya
    Ng, Bao Hui
    Li, Sam Fong Yau
    Khan, Shaheer H.
    Paulus, Aran
    Chen, Shiaw-Min
    Karger, Achim E.
    Wenz, Michael
    Ferrer, Daniel Lopez
    Huhmer, Andreas F.
    Krupke, Andreas
    COGENT CHEMISTRY, 2018, 4 (01):
  • [4] Comprehensive profiling of the complex dendrimeric contrast agent Gadomer using a combined approach of CE, MS, and CE-MS
    Vetterlein, Kai
    Bergmann, Ulf
    Bueche, Karlo
    Walker, Martina
    Lehmann, Jochen
    Linscheid, Michael W.
    Scriba, Gerhard K. E.
    Hildebrand, Michael
    ELECTROPHORESIS, 2007, 28 (17) : 3088 - 3099
  • [5] Analysis of Hemoglobin Glycation Using Microfluidic CE-MS: A Rapid, Mass Spectrometry Compatible Method for Assessing Diabetes Management
    Redman, Erin A.
    Ramos-Payan, Maria
    Mellors, J. Scott
    Ramsey, J. Michael
    ANALYTICAL CHEMISTRY, 2016, 88 (10) : 5324 - 5330
  • [6] Rapid characterization of adeno-associated virus (AAV) capsid proteins using microchip ZipChip CE-MS
    Smith, Josh
    Carillo, Sara
    Kulkarni, Aditya
    Redman, Erin
    Yu, Kate
    Bones, Jonathan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 416 (4) : 1069 - 1084
  • [7] Rapid characterization of adeno-associated virus (AAV) capsid proteins using microchip ZipChip CE-MS
    Josh Smith
    Sara Carillo
    Aditya Kulkarni
    Erin Redman
    Kate Yu
    Jonathan Bones
    Analytical and Bioanalytical Chemistry, 2024, 416 : 1069 - 1084
  • [8] CE-MS/MS and CE-timsTOF to separate and characterize intramolecular disulfide bridges of monoclonal antibody subunits and their application for the assessment of subunit reduction protocols
    Schairer, Jasmin
    Roemer, Jennifer
    Lang, Dietmar
    Neusuess, Christian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (07) : 1599 - 1612
  • [9] CE-MS/MS and CE-timsTOF to separate and characterize intramolecular disulfide bridges of monoclonal antibody subunits and their application for the assessment of subunit reduction protocols
    Jasmin Schairer
    Jennifer Römer
    Dietmar Lang
    Christian Neusüß
    Analytical and Bioanalytical Chemistry, 2024, 416 : 1599 - 1612
  • [10] Characterization of protein hydrolysates of cosmetic use by CE-MS
    Colnaghi Simionato, Ana Valeria
    Carrilho, Emanuel
    Maggi Tavares, Marina Franco
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (08) : 947 - 956