Loop-Mediated Isothermal Amplification (LAMP) Assay for Detecting Burkholderia cepacia Complex in Non-Sterile Pharmaceutical Products

被引:10
作者
Daddy Gaoh, Soumana [1 ]
Kweon, Ohgew [1 ]
Lee, Yong-Jin [2 ]
LiPuma, John J. [3 ]
Hussong, David [4 ]
Marasa, Bernard [5 ]
Ahn, Youngbeom [1 ]
机构
[1] US FDA, Natl Ctr Toxicol Res, Div Microbiol, Jefferson, AR 72079 USA
[2] Albany State Univ, Dept Nat Sci, Albany, GA 31707 USA
[3] Univ Michigan, Dept Pediat, Ann Arbor, MI 48109 USA
[4] Eagle Analyt Serv, Houston, TX 77099 USA
[5] US FDA, Ctr Drug Evaluat & Res, Off Pharmaceut Qual, Silver Spring, MD 20993 USA
来源
PATHOGENS | 2021年 / 10卷 / 09期
关键词
Burkholderia cepacia complex; loop-mediated isothermal amplification (LAMP); nuclease-free water; antiseptics; IDENTIFICATION; RECOVERY; LIQUID;
D O I
10.3390/pathogens10091071
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Simple and rapid detection of Burkholderia cepacia complex (BCC) bacteria, a common cause of pharmaceutical product recalls, is essential for consumer safety. In this study, we developed and evaluated a ribB-based colorimetric loop-mediated isothermal amplification (LAMP) assay for the detection of BCC in (i) nuclease-free water after 361 days, (ii) 10 mu g/mL chlorhexidine gluconate (CHX) solutions, and (iii) 50 mu g/mL benzalkonium chloride (BZK) solutions after 184 days. The RibB 5 primer specifically detected 20 strains of BCC but not 36 non-BCC strains. The limit of detection of the LAMP assay was 1 pg/mu L for Burkholderia cenocepacia strain J2315. Comparison of LAMP with a qPCR assay using 1440 test sets showed higher sensitivity: 60.6% in nuclease-free water and 42.4% in CHX solution with LAMP vs. 51.3% and 31.1%, respectively, with qPCR. These results demonstrate the potential of the ribB-based LAMP assay for the rapid and sensitive detection of BCC in pharmaceutical manufacturing.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis
    Kumar, Parveen
    Pandya, Deepal
    Singh, Niti
    Behera, Digambar
    Aggarwal, Praveen
    Singh, Sarman
    JOURNAL OF INFECTION, 2014, 69 (06) : 607 - 615
  • [32] An improved loop-mediated isothermal amplification assay for the detection of Mycoplasma bovis
    Higa, Yumiko
    Uemura, Ryoko
    Yamazaki, Wataru
    Goto, Shinya
    Goto, Yoshitaka
    Sueyoshi, Masuo
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2016, 78 (08) : 1343 - 1346
  • [33] Rapid identification and differentiation of Theileria sergenti and Theileria sinensis using a loop-mediated isothermal amplification (LAMP) assay
    Liu, Aihong
    Guan, Guiquan
    Du, Pengfei
    Gou, Huitian
    Zhang, Jun
    Liu, Zhijie
    Ma, Milin
    Ren, Qiaoyun
    Liu, Junlong
    Yang, Jifei
    Li, Youquan
    Niu, Qinli
    Bai, Qi
    Yin, Hong
    Luo, Jianxun
    VETERINARY PARASITOLOGY, 2013, 191 (1-2) : 15 - 22
  • [34] A novel ready-to-use loop-mediated isothermal amplification (LAMP) method for detection of Burkholderia mallei and B. pseudomallei
    Nakase, Mitsuru
    Thapa, Jeewan
    Batbaatar, Vanaabaatar
    Khurtsbaatar, Ochirbat
    Enkhtuul, Batchuluun
    Unenbat, Jugderkhorloo
    Lkham, Baasansuren
    Fujita, Sachiho
    Koshikawa, Ai
    Tuanyok, Apichai
    Saechan, Vannarat
    Higashi, Hideaki
    Hayashida, Kyoko
    Suzuki, Yasuhiko
    Nakajima, Chie
    Kimura, Takashi
    BMC MICROBIOLOGY, 2025, 25 (01):
  • [35] Development of loop-mediated isothermal amplification assay for the detection of Pythium myriotylum
    Fukuta, S.
    Takahashi, R.
    Kuroyanagi, S.
    Ishiguro, Y.
    Miyake, N.
    Nagai, H.
    Suzuki, H.
    Tsuji, T.
    Hashizume, F.
    Watanabe, H.
    Kageyama, K.
    LETTERS IN APPLIED MICROBIOLOGY, 2014, 59 (01) : 49 - 57
  • [36] Development of a Rapid, Simple Method for Detecting Naegleria fowleri Visually in Water Samples by Loop-Mediated Isothermal Amplification (LAMP)
    Mahittikorn, Aongart
    Mori, Hirotake
    Popruk, Supaluk
    Roobthaisong, Amonrattana
    Sutthikornchai, Chantira
    Koompapong, Khuanchai
    Siri, Sukhontha
    Sukthana, Yaowalark
    Nacapunchai, Duangporn
    PLOS ONE, 2015, 10 (03):
  • [37] Challenging loop-mediated isothermal amplification (LAMP) technique for molecular detection of Toxoplasma gondii
    Fallahi, Shirzad
    Mazar, Zahra Arab
    Ghasemian, Mehrdad
    Haghighi, Ali
    ASIAN PACIFIC JOURNAL OF TROPICAL MEDICINE, 2015, 8 (05) : 366 - 372
  • [38] Rapid identification of Dendrobium officinale using Loop-Mediated Isothermal Amplification (LAMP) method
    Yang Lu
    Wu Wen-Ru
    Zhou Hua
    Lai Hui-Li
    Fu Fei
    CHINESE JOURNAL OF NATURAL MEDICINES, 2019, 17 (05) : 337 - 345
  • [39] Rapid Detection of Clostridium botulinum in Food Using Loop-Mediated Isothermal Amplification (LAMP)
    Chen, Yufei
    Li, Hao
    Yang, Liu
    Wang, Lei
    Sun, Ruyi
    Shearer, Julia E. S.
    Sun, Fengjie
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (09)
  • [40] Development of a Genomics-Based LAMP (Loop-Mediated Isothermal Amplification) Assay for Detection of Pseudomonas fuscovaginae from Rice
    Ash, Gavin J.
    Lang, Jillian M.
    Triplett, Lindsay R.
    Stodart, Benjamin J.
    Verdier, Valerie
    Vera Cruz, Casiana
    Rott, Philippe
    Leach, Jan E.
    PLANT DISEASE, 2014, 98 (07) : 909 - 915