Accuracy of pedicle screw insertion in the thoraco-lumbar spine using image-guided navigation

被引:0
|
作者
Fuster, S. [1 ]
Vega, A.
Barrios, G.
Urdaneta, I.
Ojeda, O.
Macchia, M.
Combalia, A.
Berenguer, J.
Pujol, T. [1 ]
机构
[1] Univ Barcelona, Hosp Clin, Unitat Raquis, E-08036 Barcelona, Spain
来源
NEUROCIRUGIA | 2010年 / 21卷 / 04期
关键词
Accuracy; Navigation; Pedicle screw; Thoraco-lumbar spine; THORACIC SPINE; SURGICAL INDICATIONS; COMPUTED-TOMOGRAPHY; FUSION RATE; PLACEMENT; LUMBAR; FIXATION; COMPLICATIONS; STENOSIS; SURGERY;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction. Computer image guidance is one of the most significant technologic advancements in the spine surgery, because preoperative or intraoperative images can be used for multiplanar, three-dimensional intraoperative navigation. Material and methods. We performed a prospective clinical study to assess the accuracy of pedicle screw insertion using an optoelectronic navigation system (SurgiGATE Spine 2.1 Medivision). The study population included 29 patients with diverse disorders of the thoraco-lumbar spine (degenerative 54%, spondylolisthesis 21%, fractures 14%, scoliosis 7% and spondylodiscitis 4%). One patient was excluded from the study because problems with the specific instruments or the computer system. Pre and post-operative axial computed tomography images were obtained for each patient and analyzed by two independent radiologists to placement accuracy. The correct location was defined accord to Heary scale in 5 grades. Results. 163 image-guided thoraco-lumbar pedicle screws were placed 29 in the thoracolumbar spine and 134 in the lumbosacral spine. We achieved a completely intraosseous placement (Grade I) in 99.4% of lumbosacral spine screws and 100% of thoracolumbar spine screws. Only one misplaced screw (Grade III) in the pedicle of L III in the concavity of a scoliosis was reported. No implant related complications were noted. Conclusions. The low rate of misplaced screws in this prospective study compares favorably with previously published results. Our initial results indicate that Image-guided spinal surgery is a safe technique which improves surgical performance during posterior transpedicle stabilization.
引用
收藏
页码:306 / 311
页数:6
相关论文
共 50 条
  • [1] Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis
    Takahashi, Jun
    Hirabayashi, Hiroki
    Hashidate, Hiroyuki
    Ogihara, Nobuhide
    Kato, Hiroyuki
    SPINE, 2010, 35 (03) : 347 - 352
  • [2] Higher Accuracy and Better Clinical Outcomes in Navigated Thoraco-Lumbar Pedicle Screw Fixation Versus Conventional Techniques
    Papalia, Giuseppe F.
    Vadala, Gianluca
    Russo, Fabrizio
    Marcello, Gianmarco
    Nardi, Niccolo
    Papalia, Rocco
    Denaro, Vincenzo
    SPINE, 2024, 49 (19) : 1370 - 1380
  • [3] Accuracy of Pedicle Screw Insertion Among 3 Image-Guided Navigation Systems: Systematic Review and Meta-Analysis
    Du, Jin Peng
    Fan, Yong
    Wu, Qi Ning
    Wang, Dai Hua
    Zhang, Jing
    Hao, Ding Jun
    WORLD NEUROSURGERY, 2018, 109 : 24 - 30
  • [4] Routine spinal navigation for thoraco-lumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy
    Ling, Ji Min
    Dinesh, Shree Kumar
    Pang, Boon Chuan
    Chen, Min Wei
    Lim, Heng Lip
    Louange, Danny T.
    Yu, Chun Sing
    Wang, Chee Meng Ernest
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (03) : 493 - 498
  • [5] Accuracy of augmented reality surgical navigation for minimally invasive pedicle screw insertion in the thoracic and lumbar spine with a new tracking device
    Peh, Simon
    Chatterjea, Anindita
    Pfarr, Julian
    Schaefer, Jost Philipp
    Weuster, Matthias
    Klueter, Tim
    Seekamp, Andreas
    Lippross, Sebastian
    SPINE JOURNAL, 2020, 20 (04) : 629 - 637
  • [6] Image-guided pedicle screw insertion accuracy: a meta-analysis
    Tian, Nai-Feng
    Xu, Hua-Zi
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 895 - 903
  • [7] Image-guided pedicle screw insertion accuracy: a meta-analysis
    Nai-Feng Tian
    Hua-Zi Xu
    International Orthopaedics, 2009, 33 : 895 - 903
  • [8] Postoperative 320 multi-slice computed tomography in assessment of pedicle screw insertion in thoraco-lumbar fixation
    Salama, Alsiagy A.
    Amin, Mohamed A.
    Soliman, Ahmed Y.
    El-Tantaway, Ahmed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01)
  • [9] An Assistive Image-Guided Surgical Robot System Using O-Arm Fluoroscopy for Pedicle Screw Insertion: Preliminary and Cadaveric Study
    Kim, Sungmin
    Chung, Jaeheon
    Yi, Byung-Ju
    Kim, Young Soo
    NEUROSURGERY, 2010, 67 (06) : 1757 - 1767
  • [10] Upper Lumbar Pedicle Screw Insertion Using Three-Dimensional Fluoroscopy Navigation: Assessment of Clinical Accuracy
    Sugimoto, Yoshihisa
    Ito, Yasuo
    Tomioka, Masao
    Shimokawa, Tetsuya
    Shiozaki, Yasuyuki
    Mazaki, Tetsuro
    Tanaka, Masato
    ACTA MEDICA OKAYAMA, 2010, 64 (05) : 293 - 297