Application of an automated cardiopulmonary resuscitation device for kidney transplantation from uncontrolled donation after cardiac death donors in the emergency department

被引:12
|
作者
Morozumi, Junya [1 ]
Matsuno, Naoto [2 ,3 ]
Sakurai, Etsuo
Nakamura, Yuki
Arai, Takao [1 ]
Ohta, Shoichi [1 ]
机构
[1] Tokyo Med Univ, Dept Emergency & Crit Care Med, Hachioji Med Ctr, Hachioji, Tokyo 1930998, Japan
[2] Tokyo Med Univ, Dept Gen & Transplantat Surg, Hachioji Med Ctr, Hachioji, Tokyo 1930998, Japan
[3] Itabashi Chuo Med Ctr, Dept Gen Surg, Hachioji, Tokyo, Japan
关键词
automated CPR device; cardiopulmonary resuscitation; donation after cardiac death; transplantation; warm ischemic time; CHEST COMPRESSION DEVICE; MACHINE PERFUSION; ORGAN DONATION; EXPERIENCE; SUPPORT; ARREST;
D O I
10.1111/j.1399-0012.2009.01140.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Vital-organ transplantation has become acceptable as the treatment of choice for end-stage organ failure. If the patient, facing the end of life, wishes to donate organs after cardiac arrest (CA), donation after cardiac death (DCD) is increasingly important for the realization of the patient's desires after CA. In Japan, kidney transplantation from uncontrolled DCD donors, who are identified in modified Maastricht categories II or V, is one of the critical factors in expanding the donor pool. However, according to the forensic code for post-mortems and the requirement of legal consent for transplantation, the time required to meet all procedural requirements has sometimes prohibited organ procurement from uncontrolled DCD donors. We have therefore attempted to use an automated cardiopulmonary resuscitation (CPR) device and maintain arterial pressure for uncontrolled DCD donors during all interim procedures after sudden CA. Comparing kidneys procured from standard DCD donors (n = 10) and uncontrolled DCD donors (n = 4), significant differences were seen in warm ischemic time (WIT), defined as the time from CA to initiation of cooling in situ. However, our early experience showed good tolerance and viability of uncontrolled DCD kidneys. Immediate availability of an automated CPR device might provide a bridge to kidney procurement from uncontrolled DCD donors.
引用
收藏
页码:620 / 625
页数:6
相关论文
共 50 条
  • [21] Kidney Transplantation From Donors After Cardiac Death: A 25-Year Experience
    Snoeijs, Maarten G. J.
    Winkens, Bjorn
    Heemskerk, Martin B. A.
    Hoitsma, Andries J.
    Christiaans, Maarten H. L.
    Buurman, Wim A.
    van Heurn, L. W. Ernest
    TRANSPLANTATION, 2010, 90 (10) : 1106 - 1112
  • [22] Postoperative Care in Kidney Transplantation: A Comparison Between Controlled and Uncontrolled Donation After Circulatory Death
    Roldan-Reina, A. J.
    Egea-Guerrero, J. J.
    Palomo-Lopez, N.
    Cuenca-Apolo, D. X.
    Adriaensens-Perez, M.
    Porras-Lopez, M.
    Ruiz de Azua-Lopez, Z.
    Corcia-Palomo, Y.
    Martin-Villen, L.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (02) : 533 - 535
  • [23] Donor gluconate rescues livers from uncontrolled donation after cardiac death
    Limkemann, Ashley
    Lindell, Susanne L.
    Reichstetter, Heather
    Plant, Valerie
    Parrish, Dan
    Ramos, Clementina
    Kowalski, Chris
    Quintini, Cristiano
    Mangino, Martin J.
    SURGERY, 2016, 159 (03) : 852 - 861
  • [24] Transplanting kidneys from donation after cardiac death donors with acute kidney injury
    Jadlowiec, Caroline C.
    Heilman, Raymond L.
    Smith, Maxwell L.
    Khamash, Hasan A.
    Huskey, Janna L.
    Harbell, Jack
    Reddy, Kunam S.
    Moss, Adyr A.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2020, 20 (03) : 864 - 869
  • [25] Commentary on "Liver transplantation with donation-after-cardiac-death donors: A comprehensive update"
    Tsoulfas, Georgios
    JOURNAL OF SURGICAL RESEARCH, 2013, 184 (02) : 794 - 795
  • [26] Feasibility and performance of a combined extracorporeal assisted cardiac resuscitation and an organ donation program after uncontrolled cardiocirculatory death (Maastricht II)
    de Jesus, Gustavo Nobre
    Neves, Ines
    Gouveia, Joao
    Ribeiro, Joao
    PERFUSION-UK, 2024, 39 (02): : 408 - 414
  • [27] Simultaneous pancreas and kidney transplantation from organ donation after cardiac death
    Suh, Nancy
    Ryan, Brendan
    Allen, Richard
    O'Connell, Philip
    Pleass, Henry
    ANZ JOURNAL OF SURGERY, 2009, 79 (04) : 245 - 246
  • [28] Kidney from uncontrolled donors after cardiac death with one hour warm ischemic time: resuscitation by extracorporal normothermic abdominal perfusion "in situ" by leukocytes-free oxygenated blood
    Reznik, Oleg
    Skvortsov, Andrej
    Loginov, Igor
    Ananyev, Alexey
    Bagnenko, Sergey
    Moysyuk, Yan
    CLINICAL TRANSPLANTATION, 2011, 25 (04) : 511 - 516
  • [29] Kidney Graft Outcome and Quality (After Transplantation) From Uncontrolled Deceased Donors After Cardiac Arrest
    Hanf, W.
    Codas, R.
    Meas-Yedid, V.
    Berthiller, J.
    Buron, F.
    Chauvet, C.
    Brunet, M.
    Giroud, A.
    McGregor, B. C.
    Olivo-Marin, J. C.
    Hadj-Aissa, A.
    Faure, A.
    Petruzzo, P.
    Martin, X.
    Badet, L.
    Morelon, E.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 (06) : 1541 - 1550
  • [30] Machine Perfusion Preservation for Kidney Grafts With a High Creatinine From Uncontrolled Donation After Cardiac Death
    Matsuno, N.
    Konno, Y. N. O.
    Jyojima, Y.
    Akashi, I.
    Iwamoto, H.
    Hama, K.
    Hiirano, T.
    Nagao, T.
    TRANSPLANTATION PROCEEDINGS, 2010, 42 (01) : 155 - 158