Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

被引:10
|
作者
Lee, Seung Hyun [1 ]
Chang, Byung Chul [1 ]
Youn, Young-Nam [1 ]
Joo, Hyun Chel [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Sak [1 ]
机构
[1] Yonsei Univ, Coll Med, Yonsei Cardiovasc Res Inst, Severance Cardiovasc Hosp,Div Thorac & Cardiovasc, 250 Seongsanno, Seoul 03722, South Korea
来源
JOURNAL OF CARDIOTHORACIC SURGERY | 2017年 / 12卷
关键词
Heart valve prosthesis; Hemodynamics; Mitral valve; Mortality; Surgery; Valves; SURVIVAL; REGURGITATION; OUTCOMES;
D O I
10.1186/s13019-017-0653-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA). The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. Methods: From 2000 to 2013, a total of 445 patients (mean age 54.2 +/- 11.7 years) underwent isolated MVR (+/- tricuspid annuloplasty) for rheumatic disease were investigated. Effective orifice area (EOA) was determined by the continuity equation and PPM was defined as indexed EOA (EOA/BSA) <= 1.2 cm(2)/m(2). Clinical and echocardiographic follow-up (mean follow up 8.7 +/- 4.0 years) results were compared. Results: 37% of patients (n = 165) had PPM. There were no significant differences in baseline and operative characteristics between patients with and without PPM except age and IEOA. A significant decrease in mean trans-valvular pressure gradient (MPG) over time following MVR, however the change of MPG showed no differences between groups (No PPM vs. PPM: 8.9 +/- 4.7 mmHg -> 3.6 +/- 1.2 mmHg vs. 8.7 +/- 4.5 mmHg. 3.8 +/- 1.4 mmHg, p-value = 0.28). In all patients, there was a reduction of left atrium dimension (58.6 +/- 12.0 mm. 53.2 +/- 12.0 mm vs. 57.9 +/- 8.9 mm -> 52.2 +/- 8.9 mm, p-value = 0.68) and left ventricular end diastolic diameter (49.9 +/- 5.7 mm -> 48.9 +/- 5.7 mm vs. 49.7 +/- 6.0 mm -> 48.3 +/- 5.0 mm, p = 0.24) without statistical significance. Freedom from TR progression rates at 3 and 5 years (99% vs. 98%, 99% vs. 98%, p-value = 0.1), and overall survival rates at 3 and 5 years (97% vs. 96%, 94% vs. 94%, p-value = 0.7) were similar. Conclusion: This study shows that mitral PPM is not associated with atrial/ventricular remodeling and might not influence late clinical outcome including late TR progression, survival in rheumatic population.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch
    Kim, Hyo-Hyun
    Lee, Sak
    Joo, Hyun-Chel
    Kim, Jung-Hwan
    Youn, Young-Nam
    Yoo, Kyung-Jong
    Lee, Seung-Hyun
    ANNALS OF THORACIC SURGERY, 2020, 109 (03) : 661 - 667
  • [22] Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Guthoff, Henning
    Abdel-Wahab, Mohamed
    Kim, Won-Keun
    Witberg, Guy
    Wienemann, Hendrik
    Thurow, Maria
    Shamekhi, Jasmin
    Eckel, Clemens
    von der Heide, Ina
    Veulemans, Verena
    Landt, Martin
    Barbanti, Marco
    Finkelstein, Ariel
    Schewel, Jury
    Van Mieghem, Nicolas
    Adrichem, Rik
    Toggweiler, Stefan
    Rheude, Tobias
    Nombela-Franco, Luis
    Amat-Santos, Ignacio J.
    Ruile, Philipp
    Estevez-Loureiro, Rodrigo
    Bunc, Matjaz
    Branca, Luca
    De Backer, Ole
    Tarantini, Giuseppe
    Mylotte, Darren
    Arzamendi, Dabit
    Pauly, Markus
    Bleiziffer, Sabine
    Renker, Matthias
    Al-Kassou, Baravan
    Mollmann, Helge
    Ludwig, Sebastian
    Zeus, Tobias
    Tamburino, Corrado
    Schmidt, Tobias
    Rueck, Andreas
    von Stein, Philipp
    Thiele, Holger
    Abdelhafez, Ahmed
    Adam, Matti
    Baldus, Stephan
    Rudolph, Tanja
    Mauri, Victor
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) : 2626 - 2635
  • [23] Prosthesis-patient mismatch: An update
    Dumesnil J.G.
    Pibarot P.
    Current Cardiology Reports, 2011, 13 (3) : 250 - 257
  • [24] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    Blais, C
    Dumesnil, JG
    Baillot, R
    Simard, S
    Doyle, D
    Pibarot, P
    CIRCULATION, 2003, 108 (08) : 983 - 988
  • [25] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [26] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Leone, Pier Pasquale
    Pagnesi, Matteo
    Regazzoli, Damiano
    Latib, Azeem
    GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (11) : 26S - 34S
  • [27] Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Chinese Multicenter Clinical Study
    Cao, Hua
    Qiu, Zhihuang
    Chen, Liangwan
    Chen, Daozhong
    Chen, Qiang
    MEDICAL SCIENCE MONITOR, 2015, 21 : 2542 - 2546
  • [28] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Takagi, Hisato
    Umemoto, Takuya
    ANNALS OF THORACIC SURGERY, 2016, 101 (03) : 872 - 880
  • [29] Impact of prosthesis-patient mismatch on early haemodynamic status after aortic valve replacement
    Kindo, Michel
    Minh, Tam Hoang
    Perrier, Stephanie
    Petit-Eisenmann, Helene
    Bentz, Jonathan
    Cristinar, Mircea
    Ajob, Gharib
    Collange, Olivier
    Mazzucotelli, Jean-Philippe
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (01) : 48 - 54
  • [30] Impact of Prosthesis-Patient Mismatch on the Regression of Secondary Mitral Regurgitation After Isolated Aortic Valve Replacement With a Bioprosthetic Valve in Patients With Severe Aortic Stenosis
    Angeloni, Emiliano
    Melina, Giovanni
    Pibarot, Philippe
    Benedetto, Umberto
    Refice, Simone
    Ciavarella, Giuseppino M.
    Roscitano, Antonino
    Sinatra, Riccardo
    Pepper, John R.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (01) : 36 - 42