Analysis of virtual two-dimensional gels based upon affinity capillary electrophoresis hyphenated to ion trap-mass spectrometry

被引:13
作者
Machour, N
Place, J
Tron, F
Charlionet, R
Mouchard, L
Morin, C
Desbène, A
Desbène, PL
机构
[1] INSERM, Fac Mixte Med Pharm, U519, F-76183 Rouen, France
[2] Fac Sci, Atelier Bioinformat Stat & Sociolinguist, Mont St Aignan, France
[3] IRCOF, Lab Anal Syst Organ, UPRES 3233, Evreux, France
[4] IFRMP, Evreux, France
关键词
affinity capillary electrophoresis; functional proteomics; ion trap-mass spectrometry; virtual two-dimensional gels;
D O I
10.1002/elps.200410213
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Affinity capillary electrophoresis (ACE) is a robust tool for the study of noncovalent biomolecular interactions and to determine the binding constants. It is advantageous due to the speed of analysis, the high and reproducible separation efficiencies, the low consumption of analytes, the ability to study several interactions at the same time, and to cover a wide range of affinity. The use of an ion trap-mass spectrometer as a sensitive and specific detector, coupled on-line with a classical UV detector, permits extracting simultaneously the electropherograms corresponding to each ionic species. The mass spectra, acquired by scanning the results of a first separation due to ACE, were assimilated into a virtual two-dimensional (2-D) gel. We developed a software application, which was designed to create and analyze these virtual 2-D gels. The validity of this new analytical tool for probing biomolecular interactions has been demonstrated on mixtures of antibiotics of the vancomycin group and several dipeptide substrates. Using the dynamic equilibrium affinity electrophoresis approach, we have shown that molecular components interacting with a low affinity are easily located on the virtual 2-D gels, and that binding constants and stoichiometry of the interactions can be assessed. As the binding constants derived from ACE-electrospray ionization-mass spectrometry (ESI-MS) are unreliable, they must only be determined with the UV detector.
引用
收藏
页码:1466 / 1475
页数:10
相关论文
共 44 条
[11]  
GEULIN L, 2002, THESIS U ROUEN
[12]  
Guijt-van Duijn RM, 2000, ELECTROPHORESIS, V21, P3905
[13]  
Guzman NA, 2001, ELECTROPHORESIS, V22, P3602, DOI 10.1002/1522-2683(200109)22:17<3602::AID-ELPS3602>3.0.CO
[14]  
2-X
[15]  
Heegaard NHH, 1999, ELECTROPHORESIS, V20, P3122, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3122::AID-ELPS3122>3.0.CO
[16]  
2-M
[17]   Applications of affinity interactions in capillary electrophoresis [J].
Heegaard, NHH .
ELECTROPHORESIS, 2003, 24 (22-23) :3879-3891
[18]  
Heegaard NHH, 2002, ELECTROPHORESIS, V23, P815
[19]   USE OF CAPILLARY ZONE ELECTROPHORESIS TO EVALUATE THE BINDING OF ANIONIC CARBOHYDRATES TO SYNTHETIC PEPTIDES DERIVED FROM HUMAN SERUM AMYLOID-P COMPONENT [J].
HEEGAARD, NHH ;
ROBEY, FA .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2479-2482
[20]   Direct determination of solution binding constants for noncovalent complexes between bacterial cell wall peptide analogues and vancomycin group antibiotics by electrospray ionization mass spectrometry [J].
Jorgensen, TJD ;
Roepstorff, P ;
Heck, AJR .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4427-4432