"Smart" Continuous Glucose Monitoring Sensors: On-Line Signal Processing Issues

被引:53
作者
Sparacino, Giovanni [1 ]
Facchinetti, Andrea [1 ]
Cobelli, Claudio [1 ]
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
关键词
diabetes; prediction; filtering; calibration; model; time-series; DIABETIC-PATIENTS; TIME-SERIES; GLYCEMIC CONTROL; PLASMA-GLUCOSE; INSULIN; HYPOGLYCEMIA; OSCILLATIONS; VARIABILITY; CALIBRATION; EXCURSIONS;
D O I
10.3390/s100706751
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The availability of continuous glucose monitoring (CGM) sensors allows development of new strategies for the treatment of diabetes. In particular, from an on-line perspective, CGM sensors can become. smart. by providing them with algorithms able to generate alerts when glucose concentration is predicted to exceed the normal range thresholds. To do so, at least four important aspects have to be considered and dealt with on-line. First, the CGM data must be accurately calibrated. Then, CGM data need to be filtered in order to enhance their signal-to-noise ratio (SNR). Thirdly, predictions of future glucose concentration should be generated with suitable modeling methodologies. Finally, generation of alerts should be done by minimizing the risk of detecting false and missing true events. For these four challenges, several techniques, with various degrees of sophistication, have been proposed in the literature and are critically reviewed in this paper.
引用
收藏
页码:6751 / 6772
页数:22
相关论文
共 61 条
[31]  
Knobbe Edward J, 2005, Diabetes Technol Ther, V7, P15, DOI 10.1089/dia.2005.7.15
[32]   Evaluation of a new measure of blood glucose variability in diabetes [J].
Kovatchev, Boris P. ;
Otto, Erik ;
Cox, Daniel ;
Gonder-Frederick, Linda ;
Clarke, William .
DIABETES CARE, 2006, 29 (11) :2433-2438
[33]   Evaluating the accuracy of continuous glucose-monitoring sensors [J].
Kovatchev, BP ;
Gonder-Frederick, LA ;
Cox, DJ ;
Clarke, WL .
DIABETES CARE, 2004, 27 (08) :1922-1928
[34]  
Kuure-Kinsey Matthew, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P63
[35]  
Lehmann ED, 1997, DIABETES NUTR METAB, V10, P45
[36]  
Lodwig Volker, 2003, Diabetes Technol Ther, V5, P572, DOI 10.1089/152091503322250596
[37]  
LU Y, 2010, IEEE T BIOM IN PRESS
[38]   Stochastic model to assess the variability of blood glucose time series in diabetic patients self-monitoring [J].
Magni, Paolo ;
Bellazzi, Riccardo .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (06) :977-985
[39]   Meal simulation model of the glucose-insulin system [J].
Man, Chiara Dalla ;
Rizza, Robert. A. ;
Cobelli, Claudio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (10) :1740-1749
[40]   Continuous subcutaneous glucose monitoring in diabetic patients - A multicenter analysis [J].
Maran, A ;
Crepaldi, C ;
Tiengo, A ;
Grassi, G ;
Vitali, E ;
Pagano, G ;
Bistoni, S ;
Calabrese, G ;
Santeusanio, F ;
Leonetti, F ;
Ribaudo, M ;
Di Mario, U ;
Annuzzi, G ;
Genovese, S ;
Riccardi, G ;
Previti, M ;
Cucinotta, D ;
Giorgino, F ;
Bellomo, A ;
Giorgino, R ;
Poscia, A ;
Varalli, M .
DIABETES CARE, 2002, 25 (02) :347-352