The impact of low energy proton damage on the operational characteristics of EPIC-MOS CCDs

被引:13
作者
Ambrosi, RM
Smith, DR
Abbey, AF
Hutchinson, IB
Kendziorra, E
Short, A
Holland, A
Turner, MJL
Wells, A
机构
[1] Univ Leicester, Space Res Ctr, Dept Phys & Astron, Leicester LE1 7RH, Leics, England
[2] Univ Tubingen, Inst Astron & Astrophys, Tubingen, Germany
关键词
charge-coupled device; metal-oxide-semiconductor; proton damage; charge transfer inefficiency;
D O I
10.1016/S0168-583X(03)00832-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The University of Tubingen 3.5 MeV Van de Graaff accelerator facility was used to investigate the effect of low-energy protons on the performance of the European Photon Imaging Camera, metal-oxide-semiconductor, charge-coupled devices (CCDs). Two CCDs were irradiated in different parts of their detecting areas using different proton spectra and dose rates. Iron-55 was the calibration source in all cases and was used to measure any increases in charge transfer inefficiency (CTI) and spectral resolution of the CCDs. Additional changes in the CCD bright pixel table and changes in the low X-ray energy response of the device were examined. The Monte Carlo code Stopping Range of Ions in Matter was used to model the effect of a 10 MeV equivalent fluence of protons interacting with the CCD. Since the non-ionising energy loss function could not be applied effectively at such low proton energies. From the 10 MeV values, the expected CTI degradation could be calculated and then compared to the measured CTI changes. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:175 / 185
页数:11
相关论文
共 17 条
[1]   The effect of proton damage on the X-ray spectral response of MOS CCDs for the Swift X-ray telescope [J].
Ambrosi, RM ;
Short, ADT ;
Abbey, AF ;
Wells, AA ;
Smith, DR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 482 (03) :644-652
[2]  
BENNIE P, 2001, DEP PHYSICS ASTRONOM
[3]   DISPLACEMENT DAMAGE EFFECTS IN MIXED PARTICLE ENVIRONMENTS FOR SHIELDED SPACECRAFT CCDS [J].
DALE, C ;
MARSHALL, P ;
CUMMINGS, B ;
SHAMEY, L ;
HOLLAND, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (06) :1628-1637
[4]   THE EFFECT OF BULK TRAPS IN PROTON IRRADIATED EEV CCDS [J].
HOLLAND, AD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :335-343
[5]   X-ray spectroscopy using MOS CCDs [J].
Holland, AD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :334-339
[6]  
HOLLAND AD, 1994, JETX94UL230
[7]   XMM-Newton observatory I. The spacecraft and operations [J].
Jaasen, F ;
Lumb, D ;
Altieri, B ;
Clavel, J ;
Ehle, M ;
Erd, C ;
Gabriel, C ;
Guainazzi, M ;
Gondoin, P ;
Much, R ;
Munoz, R ;
Santos, M ;
Schartel, N ;
Texier, D ;
Vacanti, G .
ASTRONOMY & ASTROPHYSICS, 2001, 365 (01) :L1-L6
[8]   The effect of low energy protons on the performance of the EPIC pn-CCD detector on XMM-Newton [J].
Kendziorra, E ;
Clauss, T ;
Meidinger, N ;
Kirsch, M ;
Kuster, M ;
Risse, P ;
Hartner, G ;
Staubert, R ;
Strüder, L .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 :32-41
[9]  
NARTALLO R, 2001, ESAESTECTOSEM00015RN
[10]   Radiation environment of the Chandra X-ray Observatory [J].
O'Dell, SL ;
Bautz, MW ;
Blackwell, WC ;
Butt, YM ;
Cameron, RA ;
Elsner, RF ;
Gussenhovene, MS ;
Kolodziejczak, JJ ;
Minow, JI ;
Suggs, RM ;
Swartz, DA ;
Tennant, AF ;
Virani, SN ;
Warren, K .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 :99-110