Evaluation of segmentation algorithms for optical coherence tomography images of ovarian tissue

被引:3
作者
Sawyer, Travis W. [1 ]
Rice, Photini F. S. [2 ]
Sawyer, David M. [3 ]
Koevary, Jennifer W. [2 ]
Barton, Jennifer K. [1 ,2 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Biomed Engn, Tucson, AZ 85721 USA
[3] Tucson Med Ctr, Tucson, AZ USA
来源
DIAGNOSIS AND TREATMENT OF DISEASES IN THE BREAST AND REPRODUCTIVE SYSTEM IV | 2018年 / 10472卷
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
optical coherence tomography; image segmentation; image processing; ovarian cancer; NEURAL-NETWORK; TEXTURE ANALYSIS; DIAGNOSIS; SURVIVAL; CANCER;
D O I
10.1117/12.2283375
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Ovarian cancer has the lowest survival rate among all gynecologic cancers due to predominantly late diagnosis. Early detection of ovarian cancer can increase 5-year survival rates from 40% up to 92%, yet no reliable early detection techniques exist. Optical coherence tomography (OCT) is an emerging technique that provides depth-resolved, high-resolution images of biological tissue in real time and demonstrates great potential for imaging of ovarian tissue. Mouse models are crucial to quantitatively assess the diagnostic potential of OCT for ovarian cancer imaging; however, due to small organ size, the ovaries must first be separated from the image background using the process of segmentation. Manual segmentation is time-intensive, as OCT yields three-dimensional data. Furthermore, speckle noise complicates OCT images, frustrating many processing techniques. While much work has investigated noise-reduction and automated segmentation for retinal OCT imaging, little has considered the application to the ovaries, which exhibit higher variance and inhomogeneity than the retina. To address these challenges, we evaluated a set of algorithms to segment OCT images of mouse ovaries. We examined five preprocessing techniques and six segmentation algorithms. While all pre-processing methods improve segmentation, Gaussian filtering is most effective, showing an improvement of 32% +/- 1.2%. Of the segmentation algorithms, active contours performs best, segmenting with an accuracy of 0.948 +/- 0.012 compared with manual segmentation (1.0 being identical). Nonetheless, further optimization could lead to maximizing the performance for segmenting OCT images of the ovaries.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Computational analysis of optical coherence tomography images for the detection of soft tissue sarcomas
    Wang, Shang
    Sudheendran, Narendran
    Liu, Chih-Hao
    Manapuram, Ravi Kiran
    Zakharov, Valery P.
    Ingram, Davis R.
    Lazar, Alexander J.
    Lev, Dina C.
    Pollock, Raphael E.
    Larin, Kirill V.
    [J]. DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2013, 8580
  • [32] Texture analysis for tissue classification of optical coherence tomography images
    Gossage, KW
    Tkaczyk, TS
    Rodriguez, JJ
    Barton, JK
    [J]. ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS, 2003, 4958 : 109 - 117
  • [33] Needle Segmentation in Volumetric Optical Coherence Tomography Images for Ophthalmic Microsurgery
    Zhou, Mingchuan
    Roodaki, Hessam
    Eslami, Abouzar
    Chen, Guang
    Huang, Kai
    Maier, Mathias
    Lohmann, Chris P.
    Knoll, Alois
    Nasseri, Mohammad Ali
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (08):
  • [34] Interpretation of Optical Coherence Tomography Images for Breast Tissue Assessment
    Yemul, Kiran S.
    Zysk, Adam M.
    Richardson, Andrea L.
    Tangella, Krishnarao V.
    Jacobs, Lisa K.
    [J]. SURGICAL INNOVATION, 2019, 26 (01) : 50 - 56
  • [35] Fully automated lumen segmentation of intracoronary optical coherence tomography images
    Athanasiou, L. S.
    Rikhtegar, Farhad
    Galon, Micheli Zanotti
    Lopes, Augusto Celso
    Lemos, Pedro Alves
    Edelman, Elazer R.
    [J]. MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [36] Vessel segmentation in 2-D optical coherence tomography images
    Liu, Li-chang
    Lee, Jiann-der
    Hsu, Yu-wei
    Tseng, Scott
    Tseng, Ellen
    Tsai, Meng-tsan
    [J]. 2013 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING (CME), 2013, : 35 - 39
  • [37] Automatic Segmentation of Vessel Lumen in Intravascular Optical Coherence Tomography Images
    Wang, Ancong
    Tang, Xiaoying
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 948 - 953
  • [38] Region segmentation in 3-D optical coherence tomography images
    Chou, Cheng-wei
    Lee, Jiann-der
    Liu, Carol T.
    Tsai, Meng-tsan
    [J]. 2014 IEEE INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2014,
  • [39] BINARY TISSUE CLASSIFICATION STUDIES ON RESECTED HUMAN BREAST TISSUES USING OPTICAL COHERENCE TOMOGRAPHY IMAGES
    Bhattacharjee, M.
    Ashok, P. C.
    Rao, K. Divakar
    Majumder, S. K.
    Verma, Y.
    Gupta, P. K.
    [J]. JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2011, 4 (01) : 59 - 66
  • [40] Hierarchical enhancement of optical coherence tomography images
    Turani, Zahra
    Fatemizadeh, Emad
    Avanaki, Mohammadreza Nasiri
    [J]. 2017 24TH NATIONAL AND 2ND INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2017, : 209 - 212