Novel method for assessing postantibiotic effect by using the Coulter counter

被引:13
|
作者
Li, RC [1 ]
Lee, SW [1 ]
Lam, JS [1 ]
机构
[1] CHINESE UNIV HONG KONG,FAC MED,DEPT PEDIAT,SHATIN,HONG KONG
关键词
D O I
10.1128/AAC.40.7.1751
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To study postantibiotic effect, viable counts are routinely acquired by the pour plate technique. However, this technique is laborious and time-consuming; the required sample dilutions also cause excessive errors and material wastage. A new total cell counting technique in which a Coulter counter is used to obtain more efficient postantibiotic effect measurements has been developed.
引用
收藏
页码:1751 / 1753
页数:3
相关论文
共 50 条
  • [21] DIRECT METHOD FOR ACCURATE VOLUME MEASUREMENTS OF TETRAHYMENA WITH A COULTER COUNTER (CC)
    SKRIVER, L
    NILSSON, JR
    JOURNAL OF PROTOZOOLOGY, 1975, 22 (03): : A24 - A24
  • [22] TIME-SAVING METHOD FOR BLOOD CELL COUNTING WITH COULTER COUNTER
    MAURER, HC
    BIBLIOTHECA HAEMATOLOGICA, 1964, (18): : 19 - &
  • [23] A DIFFERENTIAL HEMOLYSIS TECHNIQUE USING A COULTER COUNTER TO ASSAY ERYTHROCYTE CHIMERISM
    NIECE, RL
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1968, 128 (01): : 36 - &
  • [24] An impedimetric approach for accurate particle sizing using a microfluidic Coulter counter
    Jagtiani, Ashish V.
    Carletta, Joan
    Zhe, Jiang
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (04)
  • [25] ANALYSIS OF PLOIDY LEVELS IN STRAINS OF VERTICILLIUM USING A COULTER-COUNTER
    TYPAS, MA
    HEALE, JB
    JOURNAL OF GENERAL MICROBIOLOGY, 1977, 101 (JUL): : 177 - 180
  • [26] A High Throughput Multiplexed Micro Coulter Counter Using Amplitude Modulation
    Jagtiani, Ashish V.
    Carletta, Joan
    Hu, Jun
    Zhe, Jiang
    2008 17TH BIENNIAL UNIVERSITY/GOVERNMENT/INDUSTRY MICRO-NANO SYMPOSIUM, PROCEEDINGS, 2008, : 173 - +
  • [27] EXPERIMENTAL AIR-EMBOLISM - MEASUREMENT OF MICROBUBBLES USING COULTER COUNTER
    GRULKE, DC
    MARSH, NA
    HILLS, BA
    BRITISH JOURNAL OF EXPERIMENTAL PATHOLOGY, 1973, 54 (06): : 684 - &
  • [28] A SIMPLE HIGHLY SENSITIVE METHOD FOR THE DETERMINATION OF CELL VIABILITY USING AN ELECTRONIC PARTICLE ANALYZER, COULTER-COUNTER
    ATTALLAH, AM
    JOHNSON, RP
    JOURNAL OF IMMUNOLOGICAL METHODS, 1981, 41 (02) : 155 - 162
  • [29] HEMOGLOBINOMETRY - COMPARISON BETWEEN HEMOGLOBIN-CYANIDE METHOD AND COULTER S COUNTER
    SALVATI, AM
    SAMOGGIA, P
    TAGGI, F
    TENTORI, L
    CLINICA CHIMICA ACTA, 1977, 77 (01) : 13 - 20
  • [30] NEW METHOD OF QUALITY-CONTROL FOR COULTER MODEL-S COUNTER
    PRANGNELL, DR
    JOHNSON, PH
    JOURNAL OF CLINICAL PATHOLOGY, 1977, 30 (05) : 487 - 491