Automated determination of glucose in soluble coffee using Prussian blue-glucose oxidase-Nafion® modified electrode

被引:21
作者
de Mattos, IL [1 ]
Areias, MCD [1 ]
机构
[1] Univ Fed Pernambuco, Dept Quim Fundamental, BR-50740540 Recife, PE, Brazil
基金
巴西圣保罗研究基金会;
关键词
modified electrode; Prussian blue; biosensor; soluble coffee; glucose;
D O I
10.1016/j.talanta.2005.01.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly selective, fast and stable biosensor for determination of glucose in soluble coffee has been developed. The biosensor electrode consist of a thin film of ferric hexacyanoferrate (Prussian Blue or PB) electrodeposited on the glassy carbon electrode (GCE) (to provide a catalytic surface for the detection of hydrogen peroxide) glucose oxidase immobilized on top of the electrode and a Nation (R) polymer layer. The stability of the PB film and the biosensor was evaluated by injecting standard-solution (50 mu M H2O2 and 0.5 mM glucose) during 4 It in a flow-injection system with the electrodes polarized at -50 mV versus Ag/AgCl. The system is able to handle about 60 samples per hour and is very stable and suitable for industrial control. Determination of glucose in the range 2.5 and 15% (w/v) in phosphate buffer with precision (r.s.d. < 1.5%) has been achieved and is in agreement with the conventional procedures. Linear calibration in the range of 0.15 and 2.50 mM with detection limits of ca. 0.03 mM has been obtained. The morphology of the enzyme glucose oxidase on the modified electrode has been analyzed by scanning electron microscopy (SEM) measurements. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1281 / 1286
页数:6
相关论文
共 39 条
[1]  
[Anonymous], 1994, ANAL ELECTROCHEMISTR
[2]   CHROMATOGRAPHIC PROFILE OF CARBOHYDRATES IN COMMERCIAL SOLUBLE COFFEES [J].
BLANC, MB ;
DAVIS, GE ;
PARCHET, JM ;
VIANI, R .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1989, 37 (04) :926-930
[3]  
Calatayud J.M.N., 1996, FLOW INJECTION ANAL
[4]   Sensor for hydrogen peroxide based on Prussian Blue modified electrode: Improvement of the operational stability [J].
de Mattos, IL ;
Gorton, L ;
Ruzgas, T ;
Karyakin, AA .
ANALYTICAL SCIENCES, 2000, 16 (08) :795-798
[5]   Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes [J].
de Mattos, IL ;
Gorton, L ;
Ruzgas, T .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :193-200
[6]   Metal-hexacyanoferrate films: A tool in analytical chemistry. [J].
de Mattos, IL ;
Gorton, L .
QUIMICA NOVA, 2001, 24 (02) :200-205
[7]   Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases (CLEC®) [J].
de Mattos, IL ;
Lukachova, LV ;
Gorton, L ;
Laurell, T ;
Karyakin, AA .
TALANTA, 2001, 54 (05) :963-974
[8]   ELECTROCHEMICAL STUDY OF MICROCRYSTALLINE SOLID PRUSSIAN BLUE PARTICLES MECHANICALLY ATTACHED TO GRAPHITE AND GOLD ELECTRODES - ELECTROCHEMICALLY INDUCED LATTICE RECONSTRUCTION [J].
DOSTAL, A ;
MEYER, B ;
SCHOLZ, F ;
SCHRODER, U ;
BOND, AM ;
MARKEN, F ;
SHAW, SJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (07) :2096-2103
[9]  
Foreman J.K., 1975, AUTOMATIC CHEM ANAL
[10]   Prussian Blue- and lactate oxidase-based amperometric biosensor for lactic acid [J].
Garjonyte, R ;
Yigzaw, Y ;
Meskys, R ;
Malinauskas, A ;
Gorton, L .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :33-38