Bispectral index, entropy, and quantitative electroencephalogram during single-agent xenon anesthesia

被引:38
|
作者
Laitio, Ruut M. [1 ,2 ]
Kaskinoro, Kimmo [1 ,2 ]
Sarkela, Mika O. K. [1 ,2 ]
Kaisti, Kaike K. [1 ,2 ]
Salmi, Elina [1 ,2 ]
Maksimow, Anu [1 ,2 ]
Langsjo, Jaakko W. [1 ,2 ]
Aantaa, Riku [1 ,2 ]
Kangas, Katja [1 ,2 ]
Jaaskelainen, Satu [1 ,2 ]
Scheinin, Harry [1 ,2 ]
机构
[1] Turku Univ Hosp, Dept Anesthesiol & Intens Care, FIN-20521 Turku, Finland
[2] Univ Turku, Turku PET Ctr, Turku, Finland
关键词
D O I
10.1097/01.anes.0000296106.52472.a6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The aim was to evaluate the performance of anesthesia depth monitors, Bispectral Index (BIS) and Entropy, during single-agent xenon anesthesia in 17 healthy subjects. Methods: After mask induction with xenon and intubation, anesthesia was continued with xenon only. BIS, State Entropy and Response Entropy, and electroencephalogram were monitored throughout induction, steady-state anesthesia, and emergence. The performance of BIS, State Entropy, and Response Entropy were evaluated with prediction probability, sensitivity, and specificity analyses. The power spectrum of the raw electroencephalogram signal was calculated. Results: The mean (SD) xenon concentration during anesthesia was 66.4% (2.4%). BIS, State Entropy, and Response Entropy demonstrated low prediction probability values at loss of response (0.455, 0.656, and 0.619) but 1 min after that the values were high (0.804, 0.941, and 0.929). Thereafter, equally good performance was demonstrated for all indices. At emergence, the prediction probability values to distinguish between steady-state anesthesia and return of response for BIS, State Entropy, and Response Entropy were 0.988, 0.892, and 0.992. No statistical differences between the performances of the monitors were observed. Quantitative electroencephalogram analyses showed generalized increase in total power (P < 0.001), delta (P < 0.001) and theta activity (P < 0.001), and increased alpha activity (P = 0.003) in the frontal brain regions. Conclusions: Electroencephalogram-derived depth of sedation indices BIS and Entropy showed a delay to detect loss of response during induction of xenon anesthesia. Both monitors performed well in distinguishing between conscious and unconscious states during steady-state anesthesia. Xenon-induced changes in electroencephalogram closely resemble those induced by propofol.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [31] Comparison of entropy and bispectral index values during propofol induction
    Balci, Canan
    Karabekir, Hamit S.
    Yigit, Muhammet
    NEUROSCIENCES, 2008, 13 (02) : 122 - 126
  • [32] Comparison between cerebral state index and bispectral index during desflurane anesthesia
    Cho, Sang-Hyeon
    Kim, Sung-Su
    Hyun, Dong-Min
    Yoon, Hyeong-Suk
    Han, Jung-Woo
    Kim, Jin Sun
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2018, 71 (06) : 447 - 452
  • [33] Comparison of entropy and bispectral index values during propofol induction
    Balci, Canan
    Karabekir, H. Selim
    Yigit, Muhammet
    ARCHIVES OF MEDICAL SCIENCE, 2007, 3 (04) : 383 - 387
  • [34] The effects of caudal local anesthesia blockade on the Bispectral Index during general anesthesia in children
    Davidson, Andrew J.
    Ironfield, Craig M.
    Skinner, Adam V.
    Frawley, Geoff P.
    PEDIATRIC ANESTHESIA, 2006, 16 (08) : 828 - 833
  • [35] Evaluation of entropy for monitoring the depth of anesthesia compared with bispectral index: a multicenter clinical trial
    Gao Jian-dong
    Zhao Yu-jie
    Xu Chen-shi
    Zhao Jing
    Huang Yu-guang
    Wang Tian-long
    Pei Ling
    Wang Jian
    Yao Li-nong
    Ding Qian
    Tan Zhi-ming
    Zhu Zhi-rong
    Yue Yun
    CHINESE MEDICAL JOURNAL, 2012, 125 (08) : 1389 - 1392
  • [36] Bispectral index monitoring during balanced xenon or sevoflurane anaesthesia in elderly patients
    Fahlenkamp, Astrid V.
    Krebber, Franziska
    Rex, Steffen
    Grottke, Oliver
    Fries, Michael
    Rossaint, Rolf
    Coburn, Mark
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (10) : 906 - 911
  • [37] A Single Dose of Esmolol Blunts the Increase in Bispectral Index to Tracheal Intubation During Sevoflurane but not Desflurane Anesthesia
    Choi, Seung Ho
    Kim, Chang Seok
    Kim, Jong Hoon
    Kim, Bum Su
    Kim, Eun Mi
    Min, Kyeong Tae
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2009, 21 (03) : 214 - 217
  • [38] Propofol Effect-Site Concentration, Bispectral Index and Spectral Entropy as Guides for Propofol Sedation during Spinal Anesthesia
    Al-metwalli, Roshdi R.
    KUWAIT MEDICAL JOURNAL, 2016, 48 (02): : 115 - 121
  • [39] Effects of etomidate on bispectral index scale and spectral entropy during induction of anesthesia by means of the raw electroencephalographic and electromyographic characteristics
    Kim, Hyun-Mok
    Shin, Sang-Wook
    Yoon, Ji-Young
    Lee, Hyeon-Jeong
    Kim, Kyung-Hoon
    Baik, Seong-Wan
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 62 (03) : 230 - 233
  • [40] How much is enough: Titrating to the bispectral index during cardiac anesthesia