Bispectral index, entropy, and quantitative electroencephalogram during single-agent xenon anesthesia

被引:38
|
作者
Laitio, Ruut M. [1 ,2 ]
Kaskinoro, Kimmo [1 ,2 ]
Sarkela, Mika O. K. [1 ,2 ]
Kaisti, Kaike K. [1 ,2 ]
Salmi, Elina [1 ,2 ]
Maksimow, Anu [1 ,2 ]
Langsjo, Jaakko W. [1 ,2 ]
Aantaa, Riku [1 ,2 ]
Kangas, Katja [1 ,2 ]
Jaaskelainen, Satu [1 ,2 ]
Scheinin, Harry [1 ,2 ]
机构
[1] Turku Univ Hosp, Dept Anesthesiol & Intens Care, FIN-20521 Turku, Finland
[2] Univ Turku, Turku PET Ctr, Turku, Finland
关键词
D O I
10.1097/01.anes.0000296106.52472.a6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The aim was to evaluate the performance of anesthesia depth monitors, Bispectral Index (BIS) and Entropy, during single-agent xenon anesthesia in 17 healthy subjects. Methods: After mask induction with xenon and intubation, anesthesia was continued with xenon only. BIS, State Entropy and Response Entropy, and electroencephalogram were monitored throughout induction, steady-state anesthesia, and emergence. The performance of BIS, State Entropy, and Response Entropy were evaluated with prediction probability, sensitivity, and specificity analyses. The power spectrum of the raw electroencephalogram signal was calculated. Results: The mean (SD) xenon concentration during anesthesia was 66.4% (2.4%). BIS, State Entropy, and Response Entropy demonstrated low prediction probability values at loss of response (0.455, 0.656, and 0.619) but 1 min after that the values were high (0.804, 0.941, and 0.929). Thereafter, equally good performance was demonstrated for all indices. At emergence, the prediction probability values to distinguish between steady-state anesthesia and return of response for BIS, State Entropy, and Response Entropy were 0.988, 0.892, and 0.992. No statistical differences between the performances of the monitors were observed. Quantitative electroencephalogram analyses showed generalized increase in total power (P < 0.001), delta (P < 0.001) and theta activity (P < 0.001), and increased alpha activity (P = 0.003) in the frontal brain regions. Conclusions: Electroencephalogram-derived depth of sedation indices BIS and Entropy showed a delay to detect loss of response during induction of xenon anesthesia. Both monitors performed well in distinguishing between conscious and unconscious states during steady-state anesthesia. Xenon-induced changes in electroencephalogram closely resemble those induced by propofol.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 50 条
  • [1] Bispectral index and state entropy of the electroencephalogram during propofol anaesthesia
    Bonhomme, V. L.
    Hans, P. C.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (01) : 145 - 146
  • [2] Bispectral index does not predict responsiveness to command during xenon anesthesia
    Goto, T
    Saito, H
    Niimi, Y
    Morita, S
    ANESTHESIOLOGY, 1999, 91 (3A) : U224 - U224
  • [3] Quantitative analysis of the electroencephalogram under desflurane anesthesia: changes in the bispectral index and suppression ratio
    Yasuhiro, W.
    Masaki, O.
    Takashi, O.
    Ryohei, S.
    Toshiya, K.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 34 - 34
  • [4] Comparison of Bispectral Index and Entropy values with electroencephalogram during surgical anaesthesia with sevoflurane
    Aho, A. J.
    Kamata, K.
    Jantti, V.
    Kulkas, A.
    Hagihira, S.
    Huhtala, H.
    Yli-Hankala, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (02) : 258 - 266
  • [5] Auditory information processing during adequate propofol anesthesia monitored by electroencephalogram bispectral index
    Kerssens, C
    Klein, J
    van der Woerd, A
    Bonke, B
    ANESTHESIA AND ANALGESIA, 2001, 92 (05): : 1210 - 1214
  • [6] Narcotrend index versus bispectral index as electroencephalogram measures of anesthetic drug effect during propofol anesthesia
    Kreuer, S
    Wilhelm, W
    Grundmann, U
    Larsen, R
    Bruhn, J
    ANESTHESIA AND ANALGESIA, 2004, 98 (03): : 692 - 697
  • [7] Correlation and agreement between bispectral index and state entropy of the electroencephalogram during propofol anaesthesia
    Bonhomme, V.
    Deflandre, E.
    Hans, P.
    BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (03) : 340 - 346
  • [8] Comparison of bispectral index and phase lag entropy during general anesthesia: Sevoflurane or propofol anesthesia
    Yoo, Jae Hwa
    Ok, Si Young
    Kim, Sang Ho
    Chung, Ji Won
    Park, Sun Young
    Kim, Mun Gyu
    Cho, Ho Bum
    Song, Sang Hoon
    Choi, Sang Jin
    Oh, Hong Chul
    MEDICINE, 2022, 101 (44) : E31191
  • [9] Narcotrend, bispectral index, and classical electroencephalogram variables during emergence from propofol/remifentanil anesthesia
    Schmidt, GN
    Bischoff, P
    Standl, T
    Voigt, M
    Papavero, L
    Esch, JSA
    ANESTHESIA AND ANALGESIA, 2002, 95 (05): : 1324 - 1330
  • [10] Entropy and bispectral index during anaesthesia in children
    Davidson, AJ
    Kim, MJ
    Sangolt, GK