Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for amperometric determination of cholesterol

被引:43
|
作者
Vidal, JC [1 ]
Garcia-Ruiz, E [1 ]
Espuelas, J [1 ]
Aramendia, T [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, Fac Sci, Dept Analyt Chem, E-50009 Zaragoza, Spain
关键词
multilayer amperometric biosensor; enzyme entrapment; electropolymerization; polypyrrole; substituted naphthalene monomers; cholesterol determination;
D O I
10.1007/s00216-003-2120-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cholesterol amperometric biosensors constructed with enzymes entrapped in electropolymerized layers of polypyrrole and poly-naphthalene derivative polymers are compared. The biosensors are based on entrapment of cholesterol oxidase and/or cholesterol esterase in monolayer or multilayer films electrochemically synthesised from pyrrole, 1,8-diaminonaphthalene (1,8-DAN), and 1,5-diaminonaphthalene (1,5-DAN) monomers. Seven configurations were assayed and compared, and different analytical properties were obtained depending on the kind of polymer and the arrangement of the layers. The selectivity properties were evaluated for the different monolayer and bilayer configurations proposed as a function of the film permeation factor. All the steps involved in the preparation of the biosensors and determination of cholesterol were carried out in a flow system. Sensitivity and selectivity depend greatly on hydrophobicity, permeability, compactness, thickness, and the kind of the polymer used. In some cases a protective outer layer of non-conducting poly(o-phenylenediamine) polymer improves the analytical characteristics of the biosensor. A comparative study was made of the analytical performance of each of the configurations developed. The biosensors were also applied to the flow-injection determination of cholesterol in a synthetic serum.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 13 条
  • [1] Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for amperometric determination of cholesterol
    J. C. Vidal
    E. Garcia-Ruiz
    J. Espuelas
    T. Aramendia
    J. R. Castillo
    Analytical and Bioanalytical Chemistry, 2003, 377 : 273 - 280
  • [2] Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films
    Singh, S
    Chaubey, A
    Malhotra, BD
    ANALYTICA CHIMICA ACTA, 2004, 502 (02) : 229 - 234
  • [3] A single step electrochemical integration of gold nanoparticles, cholesterol oxidase, cholesterol esterase and mediator with polypyrrole films for fabrication of free and total cholesterol nanobiosensors
    Rahim, Mohd Zulkhairi Abdul
    Govender-Hondros, Gwen
    Adeloju, Samuel B.
    TALANTA, 2018, 189 : 418 - 428
  • [4] An amperometric cholesterol biosensor based on cholesterol oxidase immobilized in polypyrrole on a Prussian blue modified electrode
    Li, JP
    Peng, TZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 669 - 673
  • [5] Amperometric Cholesterol Biosensors Based on the Electropolymerization of Pyrrole and Aniline in Sulphuric Acid for the Determination of Cholesterol in Serum
    Muhammet, Sinan M.
    Cete, Servet
    Arslan, Fatma
    Yasar, Ahmet
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2009, 37 (06): : 273 - 278
  • [6] An amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase
    Pundir, C. S.
    Narang, Jagriti
    Chauhan, Nidhi
    Sharma, Preety
    Sharma, Renu
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2012, 136 (04) : 633 - 640
  • [7] Amperometric urea biosensors based on the entrapment of urease in polypyrrole films
    Soares, Juliana Coatrini
    Brisolari, Andre
    Rodrigues, Valquiria da Cruz
    Sanches, Edgar Aparecido
    Goncalves, Debora
    REACTIVE & FUNCTIONAL POLYMERS, 2012, 72 (02) : 148 - 152
  • [8] Amperometric cholesterol biosensor based on reconstituted cholesterol oxidase on boronic acid functional conducting polymers
    Dervisevic, Muamer
    Cevik, Emre
    Senel, Mehmet
    Nergiz, Cevdet
    Abasiyanik, M. Fatih
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 776 : 18 - 24
  • [9] Development of a novel biosensor based on a polypyrrole-dodecylbenzene sulphonate (PPy-DBS) film for the determination of amperometric cholesterol
    Ozer, Bayram Oguz
    Cete, Servet
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2017, 45 (04) : 824 - 832
  • [10] One Step Electrode Fabrication for Direct Electron Transfer Cholesterol Biosensor Based on Composite of Polypyrrole, Green Reduced Graphene Oxide and Cholesterol Oxidase
    Pramanik, Krishnendu
    Sarkar, Priyabrata
    Bhattacharyay, Dipankar
    Majumdar, Pavel
    ELECTROANALYSIS, 2018, 30 (11) : 2719 - 2730