On Evaluation the Quality of Subjective S3D Comfort Assessment

被引:0
|
作者
Zhou, Jun [1 ,2 ]
Gu, Xiao [1 ,2 ]
Zhang, Ya [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Image Commun & Network Engn, Shanghai 200240, Peoples R China
[2] Shanghai Key Lab Digital Media Proc & Transmiss, Shanghai 200240, Peoples R China
来源
2017 IEEE INTERNATIONAL SYMPOSIUM ON BROADBAND MULTIMEDIA SYSTEMS AND BROADCASTING (BMSB) | 2017年
关键词
Subjective Quality; Single Stimulus; Pairwise Comparison; 3D Comfort; Geometric Distortion;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Stereoscopic 3D (S3D) image technology has been extensively developed in the last decades. Visual discomfort such as eye strain, headache, fatigue, asthenopia, and other phenomena leading to a less pleasant viewing experience is still a potential issue in S3D applications. How to evaluate S3D image quality that related to visual discomfort is still a challenging problem. A larger number of studies have been done on S3D Image Quality Assessment (S3D IQA) where the subjective assessed S3D Image Databases play an important role. The subjective scores were collected for each S3D image in database with a number of viewers. Usually, Likert scale is adopted for observers to mark their subjective quality score, and then mean opinion score (MOS) is estimated. Due to the law of comparative judgment, the quality of subjective scores varies among observers and depends on the judgment method. This paper studied the quality of two subjective assessment methodologies - single stimulus (SS) and pairwise comparison (PC). Considering the S3D IQA as a S3D images' quality ranking problem, we applied single stimulus and pairwise comparison subjective testing on a set of S3D images with known geometric distortions. From SS subjective testing results, the S3D images' ranking can be derived by sorting MOSs directly. From PC subjective testing results, the ranking can be derived from DMOS scores. The distorted S3D images can be ranked via their geometric distortion parameters. The quality of subjective assessed results from SS and PC are then evaluated on the correlation between their ranking results to corresponding geometric distortions. With the collected MOSs for geometric distorted S3D image database, a deep-learning based S3D IQA model was used to study the relationship between the model performance and the quality of subjective assessment.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 40 条
  • [31] PREDICTING 3D QUALITY BASED ON CONTENT ANALYSIS
    Hanhart, Philippe
    Ebrahimi, Touradj
    2013 IEEE 11TH IVMSP WORKSHOP: 3D IMAGE/VIDEO TECHNOLOGIES AND APPLICATIONS (IVMSP 2013), 2013,
  • [32] No-reference video quality assessment from artifacts and content characteristics: a neuro-fuzzy framework for video quality evaluation
    Kumar, M. Venkata Phani
    Ghosh, Monalisa
    Mahapatra, Sudipta
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 83 (16) : 48049 - 48074
  • [33] No-reference video quality assessment from artifacts and content characteristics: a neuro-fuzzy framework for video quality evaluation
    Venkata Phani Kumar M
    Monalisa Ghosh
    Sudipta Mahapatra
    Multimedia Tools and Applications, 2024, 83 : 48049 - 48074
  • [34] Evaluation of 3D Modeling Programs For Industrial Design Use
    Ozsoy, Huseyin Ozkal
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2020, 23 (04): : 1153 - 1166
  • [35] COMPARING OBJECTIVE VISUAL QUALITY IMPAIRMENT DETECTION IN 2D AND 3D VIDEO SEQUENCES
    Staelens, Nicolas
    Boussaer, Arnaud
    Vercammen, Nick
    Van Hoogenbemt, Geert
    Vermeulen, Brecht
    Demeester, Piet
    2012 FOURTH INTERNATIONAL WORKSHOP ON QUALITY OF MULTIMEDIA EXPERIENCE (QOMEX), 2012, : 224 - 229
  • [36] AGIQA-3K: An Open Database for AI-Generated Image Quality Assessment
    Li, Chunyi
    Zhang, Zicheng
    Wu, Haoning
    Sun, Wei
    Min, Xiongkuo
    Liu, Xiaohong
    Zhai, Guangtao
    Lin, Weisi
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2024, 34 (08) : 6833 - 6846
  • [37] Geometric distortion in clinical MRI systems - Part I: evaluation using a 3D phantom
    Wang, D
    Strugnell, W
    Cowin, G
    Doddrell, DM
    Slaughter, R
    MAGNETIC RESONANCE IMAGING, 2004, 22 (09) : 1211 - 1221
  • [38] Continuous table acquisition MRI for radiotherapy treatment planning: Distortion assessment with a new extended 3D volumetric phantom
    Walker, Amy
    Liney, Gary
    Holloway, Lois
    Dowling, Jason
    Rivest-Henault, David
    Metcalfe, Peter
    MEDICAL PHYSICS, 2015, 42 (04) : 1982 - 1991
  • [39] Time-course assessment of 3D-image distortion on the 1.5 T Marlin/Elekta Unity MR-LINAC
    Damyanovich, Andrei Z.
    Tadic, Tony
    Foltz, Warren D.
    Jelveh, Salomeh
    Bissonnette, Jean-Pierre
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 90 - 98
  • [40] Prospective Image Quality and Lesion Assessment in the Setting of MR-Guided Radiation Therapy of Prostate Cancer on an MR-Linac at 1.5 T: A Comparison to a Standard 3 T MRI
    Almansour, Haidara
    Afat, Saif
    Fritz, Victor
    Schick, Fritz
    Nachbar, Marcel
    Thorwarth, Daniela
    Zips, Daniel
    Mueller, Arndt-Christian
    Nikolaou, Konstantin
    Othman, Ahmed E.
    Wegener, Daniel
    CANCERS, 2021, 13 (07)