Assessing the impact of immersive simulation on clinical performance during actual in-hospital cardiac arrest with CPR-sensing technology: A randomized feasibility study

被引:45
作者
Weidman, Elizabeth K. [2 ]
Bell, George
Walsh, Deborah [2 ]
Small, Stephen [3 ,4 ]
Edelson, Dana P. [1 ,2 ]
机构
[1] Univ Chicago, Sect Hosp Med, Med Ctr, Dept Internal Med, Chicago, IL 60637 USA
[2] Univ Chicago, Emergency Resuscitat Ctr, Chicago, IL 60637 USA
[3] Univ Chicago, Dept Anesthesia & Crit Care, Chicago, IL 60637 USA
[4] Univ Chicago, Ctr Simulat & Safety Healthcare, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
Education; Cardiopulmonary resuscitation; Heart arrest; CARDIOPULMONARY-RESUSCITATION; COMPRESSION DEPTH; QUALITY; RESIDENTS; EDUCATION; GUIDELINES; SYSTEM; CARE;
D O I
10.1016/j.resuscitation.2010.05.021
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: Advanced simulation tools are increasingly being incorporated into cardiopulmonary resuscitation (CPR) training. These educational methods have been shown to improve trainee performance in simulated settings, but translation into clinical practice remains unknown for many aspects of CPR quality. This study attempts to measure the impact of simulation-based training for resuscitation team leaders on some measures of CPR quality during actual in-hospital resuscitation attempts. Methods: In this prospective, randomized interventional cluster trial, internal medicine resident physicians (post-graduate year 2) were randomized using a random number generator to participate in a 4-h, immersive simulation course in cardiopulmonary resuscitation leadership using a high-fidelity simulator with video debriefing prior to serving as resuscitation team leaders at an academic medical center. Objective metrics of actual resuscitation performance were obtained from a CPR-sensing monitor/defibrillator. Results: Thirty-two residents were randomized to receive simulation training or no additional training between April and July 2007 and data were collected following 98 actual resuscitations between July 2007 and June 2008. CPR quality from resuscitations led by 14 simulation-trained and 16 control group residents was similar in terms of mean compression depth (48 vs 49 mm; p = 0.53); compression rate (107 vs 104 min(-1); p = 0.30); ventilation rate (12 vs 12 min(-1); p = 0.45) and no-flow fraction (0.08 vs 0.07; p = 0.34). Conclusions: Although we failed to detect any significant differences in objective measures of CPR quality, we have demonstrated that CPR-sensing technology has the potential for use in assessing the impact of a simulation curriculum on some aspects of actual resuscitation performance. A larger study, performed in a setting with lower baseline performance, would be required to assess the specific simulation curriculum. (c) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1556 / 1561
页数:6
相关论文
共 22 条
  • [1] Compression depth estimation for CPR quality assessment using DSP on accelerometer signals
    Aase, SO
    Myklebust, H
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (03) : 263 - 268
  • [2] CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system
    Abella, Benjamin S.
    Edelson, Dana P.
    Kim, Salem
    Retzer, Elizabeth
    Myklebust, Helge
    Barry, Anne M.
    O'Hearn, Nicholas
    Hoek, Terry L. Vanden
    Becker, Lance B.
    [J]. RESUSCITATION, 2007, 73 (01) : 54 - 61
  • [3] Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
    Abella, BS
    Alvarado, JP
    Myklebust, H
    Edelson, DP
    Barry, A
    O'Hearn, N
    Vanden Hoek, TL
    Becker, LB
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (03): : 305 - 310
  • [4] [Anonymous], CIRCULATION
  • [5] Cost-efficiency assessment of Advanced Life Support (ALS) courses based on the comparison of advanced simulators with conventional manikins
    Iglesias-Vázquez J.A.
    Rodríguez-Núñez A.
    Penas-Penas M.
    Sánchez-Santos L.
    Cegarra-García M.
    Barreiro-Díaz M.V.
    [J]. BMC Emergency Medicine, 7 (1)
  • [6] Use of Simulation-Based Education to Reduce Catheter-Related Bloodstream Infections
    Barsuk, Jeffrey H.
    Cohen, Elaine R.
    Feinglass, Joe
    McGaghie, William C.
    Wayne, Diane B.
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (15) : 1420 - 1423
  • [7] Improving in-hospital cardiac arrest process and outcomes with performance debriefing
    Edelson, Dana P.
    Litzinger, Barbara
    Arora, Vineet
    Walsh, Deborah
    Kim, Salem
    Lauderdale, Diane S.
    Vanden Hoek, Terry L.
    Becker, Lance B.
    Abella, Benjamin S.
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2008, 168 (10) : 1063 - 1069
  • [8] Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest
    Edelson, Dana P.
    Abella, Benjamin S.
    Kramer-Johansen, Jo
    Wik, Lars
    Myklebust, Helge
    Barry, Anne M.
    Merchant, Raina M.
    Vanden Hoek, Terry L.
    Steen, Petter A.
    Becker, Lance B.
    [J]. RESUSCITATION, 2006, 71 (02) : 137 - 145
  • [9] Capnography and chest-wall impedance algorithms for ventilation detection during cardiopulmonary resuscitation
    Edelson, Dana P.
    Eilevstjonn, Joar
    Weidman, Elizabeth K.
    Retzer, Elizabeth
    Vanden Hoek, Terry L.
    Abella, Benjamin S.
    [J]. RESUSCITATION, 2010, 81 (03) : 317 - 322
  • [10] Improving CPR performance using an audible feedback system suitable for incorporation into an automated external defibrillator
    Handley, AJ
    Handley, SAJ
    [J]. RESUSCITATION, 2003, 57 (01) : 57 - 62