Meta-analysis of Different Pressing Time on the Incidence of Subcutaneous Hemorrhage of Low Molecular Weight Heparin Administration

被引:1
作者
Fang, Juan [1 ]
Pan, Gefeng [1 ]
Bao, Xufei [1 ]
Wang, Yanhong [1 ]
机构
[1] Zhejiang Hosp, Hangzhou, Zhejiang, Peoples R China
关键词
low molecular weight heparin; subcutaneous injection; pressing time; subcutaneous hemorrhage; meta-analysis; INJECTION DURATION;
D O I
10.1177/10760296211038682
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To investigate the effect of different pressing time on the incidence of subcutaneous hemorrhage of low molecular weight heparin (LMWH) administration by meta-analysis. Cochrane Library, PubMed, MEDLINE, CINAHL, EMbase, Springer, EBSCO, China Biomedical Literature Database, CNKI, Wanfang Database, and VIP Database were searched. To screen the literature of randomized controlled trials with different pressing time in patients with subcutaneous LMWH injection from the establishment of the database to December 2020. The quality of the literature was evaluated and the data were extracted. Meta-analysis was performed by RevMan 5.3. A total of 17 randomized controlled trials were included. Meta-analysis showed that the bleeding rate of pressing for 5 min odds ratio (OR = 3.89, 95% confidence interval [CI]: 2.68-5.64, P < .05) or pressing for 10 min (OR = 1.99, 95% CI: 1.34-2.95) was significantly lower than that of pressing for 3 min. Moreover, the bleeding rate was significantly lower in the 5 min pressing (OR = 1.47, 95% CI: 1.18-1.82) and 10 min pressing(OR = 2.12, 95% CI: 1.61-2.77) than in the no compression group. It is the most suitable time to press 5 min after subcutaneous LMWH injection, which can better control the incidence of bleeding.
引用
收藏
页数:8
相关论文
共 26 条
[1]   Effect of injection duration on bruising associated with subcutaneous heparin: A quasi-experimental within-subject design [J].
Akpinar, Reva Balci ;
Celebioglu, Ayda .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 2008, 45 (06) :812-817
[2]   Current dosing of low-molecular-weight heparins does not reflect licensed product labels: an international survey [J].
Barras, Michael A. ;
Kirkpatrick, Carl M. J. ;
Green, Bruce .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2010, 69 (05) :520-528
[3]   Effects of injection duration on site-pain intensity and bruising associated with subcutaneous heparin [J].
Chan, H .
JOURNAL OF ADVANCED NURSING, 2001, 35 (06) :882-892
[4]  
DiHong Y., 2010, TIANJIN J NURS, V18, P249
[5]  
Haiyan W., 2011, MOD J INTEGR TRADITI, V20, P1792
[6]  
Haoyun Y., 2016, J QILU NUR, V22, P94
[7]  
HIGGINS JPT, 2011, COCHRANE HDB SYSTEMA, V0001
[8]  
Huilan K., 2012, CHINESE NURS RES, V26, P2256
[9]  
Jinjie H., 2015, YIAYAO QIANYAN, V5, P172
[10]  
Li W., 2011, ANHUI MED PHARM J, V15, P1178