Clinical comparison of two stylet angles for orotracheal intubation with the GlideScope video Laryngoscope

被引:31
作者
Dupanovic, Mirsad
Isaacson, Sheldon A.
Borovcanin, Zana
Jain, Sushma
Korten, Santiago
Karan, Suzanne
Messing, Susan P.
机构
[1] Univ Rochester, Sch Med & Dent, Dept Anesthesiol, Rochester, NY 14642 USA
[2] Univ Rochester, Sch Med & Dent, Dept Biostat, Rochester, NY 14642 USA
关键词
Endotracheal tube; GlideScope video laryngoscope; Orotracheal intubation; VIDEOLARYNGOSCOPE GLIDESCOPE(R); ENDOTRACHEAL-TUBE; SYSTEM;
D O I
10.1016/j.jclinane.2009.10.008
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To compare the success of orotracheal intubation in 62 seconds or less using the Glide Scope video laryngoscope (GVL) and a 60 degrees or 90 degrees angled stylet with reverse loading of the endotracheal tube (ETT) Design: Prospective, randomized study Setting: Operating room of a university hospital Patients: 120 ASA physical status I, II, and In adult patients undergoing elective surgery requiring general anesthesia with orotracheal intubation Interventions: Patients were randomly allocated to two groups (n = 60 each), both groups received general anesthesia and neuromuscular relaxation A conventional ETT was styleted and then bent from its straight configuration Just above the cuff, either at 60 degrees or 90 degrees against its concave natural curve (reverse loading) Four attending anesthesiologists, who were blinded as to stylet assignment (the 60 or 90 group), intubated the tracheas of all patients with the GVL using either the primary or secondary stylet Measurements: The primary outcome was success of orotracheal mtubation in 62 seconds or less The secondary outcome was actual time to mtubation (TTI) Main Results: The odds ratio (OR) for mtubation success was higher in the 90 degrees group than the 60 degrees group (OR = 10 41, P < 0 03), as evidenced by 59 of 60 patients whose tracheas were mtubated successfully within 62 seconds, compared with 51 of 60 patients in the 60 degrees group Seven of the 9 failures were due to inability of the 60 degrees stylet to reach the glottic opening The three remaining failures were associated with TTI of more than 62 seconds
引用
收藏
页码:352 / 359
页数:8
相关论文
共 18 条
[1]  
Cooper RM, 2005, CAN J ANAESTH, V52, P191, DOI 10.1007/BF03027728
[2]  
Cooper RM, 2004, CAN J ANAESTH, V51, P95, DOI 10.1007/BF03018567
[3]  
Cooper RM, 2003, CAN J ANAESTH, V50, P611, DOI 10.1007/BF03018651
[4]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[5]  
Doyle DJ, 2004, CAN J ANAESTH, V51, P95
[6]   Intubation with the GlideScope® videolarynyoscope using the ''gear stick technique" [J].
Dupanovic, M ;
Diachun, CAB ;
Isaacson, SA ;
Layer, D .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2006, 53 (02) :213-214
[7]   Angled or curved stylet for intubation with the GlideScope®? [J].
Dupanovic, Mirsad .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (06) :487-488
[8]   Optimizing GlideScope® laryngoscopy:: An in vitro study on an airway model [J].
Dupanovic, Mirsad ;
Jensen, Richard .
ANESTHESIOLOGY, 2007, 106 (04) :886-888
[9]   The StyletScope® facilitates tracheal intubation with the GlideScope® [J].
Hirabayashi, Yoshihiro .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2006, 53 (12) :1263-1264
[10]  
Hosmer W., 2000, Applied Logistic Regression, VSecond