Tomographic digital subtraction angiography for lung perfusion estimation in rodents

被引:21
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Lin, Ming De [1 ]
Mackel, Julie S. Boslego [1 ]
Samei, Ehsan [1 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
关键词
x-ray; digital subtraction angiography; tomosynthesis; small animal; lung; perfusion; functional imaging; IMAGE QUALITY; SMALL ANIMALS; CONTRAST; TOMOSYNTHESIS; CT;
D O I
10.1118/1.2717384
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In vivo measurements of perfusion present a challenge to existing small animal imaging techniques such as magnetic resonance microscopy, micro computed tomography, micro positron emission tomography, and microSPECT, due to combined requirements for high spatial and temporal resolution. We demonstrate the use of tomographic digital subtraction angiography (TDSA) for estimation of perfusion in small animals. TDSA augments conventional digital subtraction angiography (DSA) by providing three-dimensional spatial information using tomosynthesis algorithms. TDSA is based on the novel paradigm that the same time density curves can be reproduced in a number of consecutive injections of mu L volumes of contrast at a series of different angles of rotation. The capabilities of TDSA are established in studies on lung perfusion in rats. Using an imaging system developed in-house, we acquired data for four-dimensional (4D) imaging with temporal resolution of 140 ms, in-plane spatial resolution of 100 mu m, and slice thickness on the order of millimeters. Based on a structured experimental approach, we optimized TDSA imaging providing a good trade-off between slice thickness, the number of injections, contrast to noise, and immunity to artifacts. Both DSA and TDSA images were used to create parametric maps of perfusion. TDSA imaging has potential application in a number of areas where functional perfusion measurements in 4D can provide valuable insight into animal models of disease and response to therapeutics. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1546 / 1555
页数:10
相关论文
共 27 条
[1]  
American Society for Testing and Materials (ASTM), 1995, STAND TEST METH MEAS
[2]  
ANDERSON RE, 1984, AM J NEURORADIOL, V5, P277
[3]  
Badea C, 2001, ACTA RADIOL, V42, P244, DOI 10.1080/028418501127346585
[4]   Micro-CT with respiratory and cardiac gating [J].
Badea, C ;
Hedlund, LW ;
Johnson, GA .
MEDICAL PHYSICS, 2004, 31 (12) :3324-3329
[5]   Tumor imaging in small animals with a combined micro-CT/micro-DSA system using iodinated conventional and blood pool contrast agents [J].
Badea, Cristian T. ;
Hedlund, Laurence W. ;
De Lin, Ming ;
Mackel, Julie F. Boslego ;
Johnson, G. Allan .
CONTRAST MEDIA & MOLECULAR IMAGING, 2006, 1 (04) :153-164
[6]   Assessment of tumor blood perfusion by high-resolution dynamic contrast-enhanced MRI: A preclinical study of human melanoma xenografts [J].
Benjaminsen, IC ;
Graff, BA ;
Brurberg, KG ;
Rofstad, EK .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :269-276
[7]  
Constantinesco A, 2005, J NUCL MED, V46, P1005
[8]   Optimized radiographic spectra for small animal digital subtraction angiography [J].
De Lin, Ming ;
Samei, Ehsan ;
Badea, Cristian T. ;
Yoshizumi, Terry T. ;
Johnson, G. Allan .
MEDICAL PHYSICS, 2006, 33 (11) :4249-4257
[9]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[10]  
DU LY, 2006, P SOC PHOTO-OPT INS, V6142, P614