Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer

被引:87
|
作者
Patel, RR
Orton, N
Tomé, WA
Chappell, R
Ritter, MA
机构
[1] Univ Wisconsin, Dept Radiat Oncol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Biostat & Informat, Madison, WI 53792 USA
关键词
prostate cancer; conformal radiotherapy; endorectal balloon; ultrasound localization; rectal toxicity;
D O I
10.1016/S0167-8140(03)00056-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To compare the rectal wall and bladder volume in the high dose region with or without the use of a balloon catheter with both three-dimensional (3D)-conformal and intensity modulated radiation therapy (CRT, IMRT) approaches in the treatment of prostate cancer. Material and methods: Five patients with a wide range of prostate volumes and treated with primary external beam radiation therapy for localized prostate cancer were selected for analysis. Pinnacle(TM) treatment plans were generated utilizing a 3D conformal six-field design and an IMRT seven coplanar-field plan with a novel, three-step optimization and with ultrasound localization. Separate plans were devised with a rectal balloon deflated or air inflated with and without inclusion of the seminal vesicles (SV) in the target volume. The prescription dose was 76 Gy in 38 fractions of 2 Gy each. Cumulative dose-volume histograms (DVHs) were analyzed for the planning target volume (PTV), rectal wall. and bladder with an inflated (60 cc air) or deflated balloon with and without SV included. The volumes of rectal wall and bladder above 60, 65, and 70 Gy with each treatment approach were evaluated. Results: Daily balloon placement was well-tolerated with good patient positional reproducibility. Inflation of the rectal balloon in all cases resulted in a significant decrease in the absolute volume of rectal wall receiving greater than 60, 65, or 70 Gy. The rectal sparing ratio (RSR), consisting of a structure's high dose volume with the catheter inflated, divided by the volume with the catheter deflated, was calculated for each patient with and without seminal vesicle inclusion for 3D-CRT and IMRT. For 3D-CRT, RSRs with SV included were 0.59, 0.59, and 0.56 and with SV excluded were 0.60, 0.58, and 0.54 at doses of greater than 60, 65, and 70 Gy, respectively. Similarly, for IMRT, the mean RSRs were 0.59. 0.59, and 0.63 including SV and 0.71, 0.66, and 0.67 excluding SV at these same dose levels, respectively. Averaged over all conditions, inflation of the rectal balloon resulted in a significant reduction in rectal volume receiving ! 65 Gy to a mean ratio of 0.61 (P = 0.01) or. in other words, a mean fractional high dose rectal sparing of 39%. There was a slight overall increase to 1.13 in the relative volume of bladder receiving at least 65 Gy; however, this was not significant (P = 0.6). Use of an endorectal balloon with a non-image-guided 3D-CRT plan produced about as much rectal dose sparing as a highly conformal, image-guided IMRT approach without a balloon. However. inclusion of a balloon with IMRT produced further rectal sparing still. Conclusion: These results indicate that use of a rectal balloon with a 3D-CRT plan incorporating typical treatment margins will produce significant high dose rectal sparing that is comparable to that achieved by a highly conformal IMRT with ultrasound localization. Further sparing is achieved with the inclusion of a balloon catheter in an IMRT plan. Thus, in addition to a previously reported advantage of prostate immobilization. the use of a rectal displacement balloon during daily treatment results in high dose rectal wall sparing during both modestly and highly conformal radiotherapy. Such sparing could assist in controlling and limiting rectal toxicity during increasingly aggressive dose escalation. (C) 2003 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 50 条
  • [31] Time course of late rectal toxicity after radiation therapy for prostate cancer
    Odrazka, K.
    Dolezel, M.
    Vanasek, J.
    Vaculikova, M.
    Zouhar, M.
    Sefrova, J.
    Paluska, P.
    Vosmik, M.
    Kohlova, T.
    Kolarova, I.
    Macingova, Z.
    Navratil, P.
    Brodak, M.
    Prosvic, P.
    PROSTATE CANCER AND PROSTATIC DISEASES, 2010, 13 (02) : 138 - 143
  • [32] Rectal Radiation Dose and Clinical Outcomes in Prostate Cancer Patients Treated With Stereotactic Body Radiation Therapy With and Without Hydrogel
    Kundu, Palak
    Lin, Eric Y.
    Yoon, Stephanie M.
    Parikh, Neil R.
    Ruan, Dan
    Kishan, Amar U.
    Lee, Alan
    Steinberg, Michael L.
    Chang, Albert J.
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [33] Rectal wall sparing effect of three different endorectal balloons in 3D conformal and IMRT prostate radiotherapy
    Van Lin, ENJT
    Hoffmann, AL
    Van Kollenburg, P
    Leer, JW
    Visser, AG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : 565 - 576
  • [34] Impact of Radiation Therapy Dose Escalation on Prostate Cancer Outcomes and Toxicities
    Zaorsky, Nicholas G.
    Keith, Scott W.
    Shaikh, Talha
    Nguyen, Paul L.
    Horwitz, Eric M.
    Dicker, Adam P.
    Den, Robert B.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2018, 41 (04): : 409 - 415
  • [35] Ion therapy of prostate cancer: daily rectal dose reduction by application of spacer gel
    Rucinski, Antoni
    Brons, Stephan
    Richter, Daniel
    Habl, Gregor
    Debus, Juergen
    Bert, Christoph
    Haberer, Thomas
    Jaekel, Oliver
    RADIATION ONCOLOGY, 2015, 10
  • [36] Optimization of conformal radiation treatment of prostate cancer: Report of a dose escalation study
    Hanks, GE
    Schultheiss, TE
    Hanlon, AL
    Hunt, M
    Lee, WR
    Epstein, BE
    Coia, LR
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (03): : 543 - 550
  • [37] Impact of transperineal ultrasound on perineal skin dose in prostate radiation therapy
    De Silva, Kalani
    Brown, Amy
    Edwards, Christopher
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 23 : 27 - 32
  • [38] Salvage radiation therapy in prostate cancer: relationship between rectal dose and long-term, self-reported rectal bleeding
    Braide, K.
    Kindblom, J.
    Lindencrona, U.
    Hugosson, J.
    Pettersson, N.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2021, 23 (02): : 397 - 404
  • [39] Salvage radiation therapy in prostate cancer: relationship between rectal dose and long-term, self-reported rectal bleeding
    K. Braide
    J. Kindblom
    U. Lindencrona
    J. Hugosson
    N. Pettersson
    Clinical and Translational Oncology, 2021, 23 : 397 - 404
  • [40] Dose-Escalated Radiation Therapy for Intermediate-Risk Prostate Cancer
    Liauw, Stanley L.
    Fricano, Janine
    Correa, David
    Weichselbaum, Ralph R.
    Jani, Ashesh B.
    CANCER, 2009, 115 (08) : 1784 - 1790