A novel self-propelled disposable colonoscope is effective for colonoscopy in humans

被引:39
作者
Gluck, Nathan [1 ,2 ]
Melhem, Alaa [1 ,2 ]
Halpern, Zamir [1 ,2 ]
Mergener, Klaus [3 ]
Santo, Erwin [1 ,2 ]
机构
[1] Tel Aviv Univ, Tel Aviv Med Ctr, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
[3] Digest Hlth Serv, Tacoma, WA USA
关键词
PROOF-OF-CONCEPT; COLORECTAL-CANCER; GASTROINTESTINAL ENDOSCOPY; ADENOMA DETECTION; MISS RATES; INFECTION; SURVEILLANCE; TRANSMISSION; SOCIETY; FORCE;
D O I
10.1016/j.gie.2015.08.083
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: The self-propelled disposable colonoscope (SPDC) with a 360 degrees view is designed to enhance visualization, minimize risks of perforation and infection transmission, and shorten operator training time associated with conventional colonoscopy (CC). We evaluated SPDC efficacy for cecal intubation and safety. Methods: Prospective patients presenting for colorectal cancer screening underwent SPDC immediately followed by CC. Initial patients necessary for SPDC operators to achieve proficiency comprised the training cohort. Subsequent enrolled patients comprised the study cohort. SPDC colonoscopy was performed up to the cecum, where anatomic landmarks were photographed and mucosal suction marks were placed. During SPDC withdrawal, polyps were recorded and similarly marked. On the second pass (by using CC), any potential mucosal damage and suction marks from the SPDC as well as polyps were recorded. Main endpoints included SPDC cecal intubation rates, confirmed by anatomic landmarks and residual marks seen on subsequent CC, and frequency and severity of adverse events and mucosal damage with SPDC. The secondary endpoint was subjective procedure proficiency, evaluated by the operator based on the training cohort. The tertiary endpoint was documenting pathologies visualized with SPDC. Results: Fifty-six of 58 enrolled subjects completed the study. Proficiency with SPDC was attained after 8 to 10 procedures. Cecal intubation was successful in 98.2% (55/56 subjects; 95% confidence interval [CI], 90.4%-99.9%), including 100% (95% CI, 90.7%-100%) of the study cohort and 94.4% (95% CI, 72.7%-99.9%) of the training cohort. No mucosal damage or adverse events were reported. SPDC detected 87.5% of polyps seen in tandem CC, including all polyps larger than 5 mm. Conclusions: SPDC was highly successful, simple to use, and safe in achieving complete colonoscopy (cecal intubation).
引用
收藏
页码:998 / U176
页数:8
相关论文
共 31 条
[1]  
[Anonymous], DES END RETR CHOL ER
[2]   Proof-of-concept study of the Aer-O-Scope™ omnidirectional colonoscopic viewing system in ex vivo and in vivo porcine models [J].
Arber, N. ;
Grinshpon, R. ;
Pfeffer, J. ;
Maor, L. ;
Bar-Meir, S. ;
Rex, D. .
ENDOSCOPY, 2007, 39 (05) :412-417
[3]   Infection control during GI endoscopy [J].
Banerjee, Subhas ;
Shen, Bo ;
Nelson, Douglas B. ;
Lichtenstein, David R. ;
Baron, Todd H. ;
Anderson, Michelle A. ;
Dominitz, Jason A. ;
Gan, S. Ian ;
Harrison, M. Edwyn ;
Ikenberry, Steven O. ;
Jagannath, Sanjay B. ;
Fanelli, Robert D. ;
Lee, Ken ;
van Guilder, Trina ;
Stewart, Leslie E. .
GASTROINTESTINAL ENDOSCOPY, 2008, 67 (06) :781-790
[4]   Reduced Risk of Colorectal Cancer Up to 10 Years After Screening, Surveillance, or Diagnostic Colonoscopy [J].
Brenner, Hermann ;
Chang-Claude, Jenny ;
Jansen, Lina ;
Knebel, Phillip ;
Stock, Christian ;
Hoffmeister, Michael .
GASTROENTEROLOGY, 2014, 146 (03) :709-717
[5]   Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes [J].
Chiu, King-Wah ;
Tsai, Ming-Chao ;
Wu, Keng-Liang ;
Chiu, Yi-Chun ;
Lin, Ming-Tzung ;
Hu, Tsung-Hui .
BMC GASTROENTEROLOGY, 2012, 12
[6]   New Delhi Metallo-β-Lactamase-Producing Carbapenem-Resistant Escherichia coli Associated With Exposure to Duodenoscopes [J].
Epstein, Lauren ;
Hunter, Jennifer C. ;
Arwady, M. Allison ;
Tsai, Victoria ;
Stein, Linda ;
Gribogiannis, Marguerite ;
Frias, Mabel ;
Guh, Alice Y. ;
Laufer, Alison S. ;
Black, Stephanie ;
Pacilli, Massimo ;
Moulton-Meissner, Heather ;
Rasheed, J. Kamile ;
Avillan, Johannetsy J. ;
Kitchel, Brandon ;
Limbago, Brandi M. ;
MacCannell, Duncan ;
Lonsway, David ;
Noble-Wang, Judith ;
Conway, Judith ;
Conover, Craig ;
Vernon, Michael ;
Kallen, Alexander J. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (14) :1447-1455
[7]  
Gluck N, 2014, GASTROENTEROLOGY, V146, pS406
[8]   Patient-to-patient transmission of hepatitis C virus (HCV) during colonoscopy diagnosis [J].
Gonzalez-Candelas, Fernando ;
Guiral, Silvia ;
Carbo, Rosa ;
Valero, Ana ;
Vanaclocha, Hermelinda ;
Gonzalez, Francisco ;
Alma Bracho, Maria .
VIROLOGY JOURNAL, 2010, 7
[9]   Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicentre, randomised, tandem colonoscopy trial [J].
Gralnek, Ian M. ;
Siersema, Peter D. ;
Halpern, Zamir ;
Segol, Ori ;
Melhem, Alaa ;
Suissa, Alain ;
Santo, Erwin ;
Sloyer, Alan ;
Fenster, Jay ;
Moons, Leon M. G. ;
Dik, Vincent K. ;
D'Agostino, Ralph B., Jr. ;
Rex, Douglas K. .
LANCET ONCOLOGY, 2014, 15 (03) :353-360
[10]   Comparison of adenoma detection and miss rates between a novel balloon colonoscope and standard colonoscopy: a randomized tandem study [J].
Halpern, Zamir ;
Gross, Seth A. ;
Gralnek, Ian M. ;
Shpak, Beni ;
Pochapin, Mark ;
Hoffman, Arthur ;
Mizrahi, Meir ;
Rochberger, Yosef S. ;
Moshkowitz, Menachem ;
Santo, Erwin ;
Melhem, Alaa ;
Grinshpon, Roman ;
Pfefer, Jorge ;
Kiesslich, Ralf .
ENDOSCOPY, 2015, 47 (03) :238-244