Air-coupled ultrasonic bending plate transducer with piezoelectric and electrostatic transduction element combination

被引:0
|
作者
Rutsch, Matthias [1 ]
Ben Dali, Omar [1 ]
Jaeger, Axel [1 ]
Allevato, Gianni [1 ]
Beerstecher, Kai [1 ]
Cardoletti, Juliette [1 ]
Radetinac, Aldin [1 ]
Alff, Lambert [1 ]
Kupnik, Mario [1 ]
机构
[1] Tech Univ Darmstadt, Darmstadt, Germany
关键词
Piezoelectric and electrostatic transduction; transducer radiation pattern; FEM;
D O I
10.1109/ultsym.2019.8925701
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a simulation of an ultrasonic transducer element with piezoelectric and electrostatic transduction combined and with two bending plates. It combines the high SPL of a piezoelectric transducer with the tunable resonance frequency of a CMUT due to spring softening effect. In this work, we compare two state-of-the-art transducers with our approach: First, a piezoelectric bending plate transducer, based on a Murata MA40S4S transducer; second, a piezoelectric bending plate positioned above an additional electrode (piezoelectric and electrostatic transduction principle combined) and, third, a new structure, based on two bending plates with piezoelectric and electrostatic transduction combined (piezoelectric and electrostatic double-bending plate transducer). We use COMSOL Multiphysics 5.4 for creating a multiphysical model, including the electrical, mechanical and acoustical domain. We simulate mechanical total displacement and the directivity pattern. Thermoviscous losses in the air gap between the two bending plates are considered as well. The double-bending plate transducer has an increased amplitude of up to 570% at 80% of the pull-in voltage and a tunable resonance frequency of up to 21 %. Compared to piezoelectric and electrostatic bending plate transducer, the total displacement is doubled. In addition, the radiation pattern is approximately omnidirectional, and, thus, beneficial for various applications such as obstacle detection, flow metering, distance measurement or anemometry.
引用
收藏
页码:147 / 150
页数:4
相关论文
共 50 条
  • [31] Design of a hexagonal air-coupled capacitive micromachined ultrasonic transducer for air parametric array
    Zhang, Xiaoli
    Zhang, Hui
    Li, Dachao
    NANOTECHNOLOGY AND PRECISION ENGINEERING, 2021, 4 (01)
  • [32] Ultrasonic imaging using laser generation and piezoelectric air-coupled detection
    Wright, WMD
    Hutchins, DA
    Hayward, G
    Gachagan, A
    ULTRASONICS, 1996, 34 (2-5) : 405 - 409
  • [33] Development of a Spherically Focused Capacitive-film Air-coupled Ultrasonic Transducer
    Song, Junho
    Chimenti, Dale E.
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2005, 25 (06) : 446 - 450
  • [34] Measurement of air-coupled transducer characteristics for ultrasonic non-destructive evaluation
    Biateau, C
    Hosten, B
    Roziere, D
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 21A & B, 2002, 615 : 921 - 928
  • [35] Ultrasonic imaging of solid surfaces using a focussed air-coupled capacitance transducer
    Schindel, DW
    ULTRASONICS, 1998, 35 (08) : 587 - 594
  • [36] Ultrasonic detection by photo-EMF sensor and by wideband air-coupled transducer
    Cerniglia, D
    Djordjevic, BB
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2004, 15 (03) : 111 - 117
  • [37] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Univ of Strathclyde, Glasgow, United Kingdom
    IEEE Trans Ultrason Ferroelectr Freq Control, 6 (1549-1558):
  • [38] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Galbraith, W
    Hayward, G
    Benny, G
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 917 - 920
  • [39] Test, modeling, and analysis of air-coupled ultrasonic transducer based on piezoelectret film
    Zhang, Fenglin
    Pan, Yongdong
    Zhao, Jinfeng
    Zhang, Xiaoqing
    AIP ADVANCES, 2020, 10 (06)
  • [40] Noncontact photoacoustic angiography with an air-coupled ultrasonic transducer for evaluation of burn injury
    Ma, Haigang
    Xiong, Kedi
    Wu, Junwei
    Ji, Xuanrong
    Yang, Sihua
    APPLIED PHYSICS LETTERS, 2019, 114 (13)