A comparative study for stator winding inter-turn short-circuit fault detection based on harmonic analysis of induction machine signatures

被引:14
|
作者
Zorig, Assam [1 ,2 ]
Kia, Shahin Hedayati [2 ]
Chouder, Aissa [1 ]
Rabhi, Abdelhamid [2 ]
机构
[1] Univ Med Boudiaf msila, Lab Elect Engn LGE, Msila, Algeria
[2] Univ Picardie Jules Verne, Lab Modeling, Informat & Syst, Amiens, France
关键词
Induction motors; Modeling; Finite element method (FEM); Diagnostic; Harmonics; Monitoring; Signal processing; AIR-GAP TORQUE; ROTOR BAR; DIAGNOSIS; MOTORS; FUSION;
D O I
10.1016/j.matcom.2022.01.019
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This article deals with inter-turn short-circuit fault detection in stator windings of squirrel cage induction machines. The main aim is to perform harmonic analysis of different electrical signatures namely the stator phase current, external magnetic flux and electromagnetic torque at different levels of mechanical load in order to develop an efficient fault detection approach of this kind of defect in induction machines. The proposed approach is based on the analysis of saturation related harmonics at rank 3k(1) f(s), where k(1) is an odd number, and magnetomotive force (MMF)-related harmonics at rank (6k(2) +/- 1) f(s), with k(2) = 1, 2, ... in stator phase current and stray flux and harmonics at rank 2k(2) f(s) in electromagnetic torque. The amplitudes of these last harmonics in healthy condition are compared with 3% power supply unbalance, 16.6% (40 turns) and 33% (80 turns) levels of inter-turn short-circuit fault in frequency range from 0 Hz to 2500 Hz under different levels of mechanical load. Besides, the stand-still test is also investigated in this work. Simulation study is carried out based on 2.2kW squirrel cage IM using finite element method (FEM). This method provides accurate and inexpensive tool for evaluating the performance of induction machine under healthy and faulty conditions. The obtained results demonstrate that the stray flux is the most sensitive signature to the stator winding inter-turn short-circuit fault, and it is robust against the power supply unbalance in comparison with both stator current and electromagnetic torque. (c) 2022 International Association for Mathematics and Computers in Simulation (IMACS). Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:273 / 288
页数:16
相关论文
共 50 条
  • [21] A Survey of Fault Indicatiors for Stator Winding Inter-Turn Fault Detection in Low-Voltage Induction Machines
    VietHung Nguyen
    Wang, Danwei
    Yu, Ming
    Vaiyapuri, Viswanathan
    Nadarajan, Sivakumar
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1385 - 1390
  • [22] Sliding Mode Observer-Based Fault-Detection of Inter-Turn Short-Circuit in Induction Motor
    Sellami, T.
    Berriri, H.
    Jelassi, S.
    Mimouni, M. F.
    14TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL & COMPUTER ENGINEERING STA 2013, 2013, : 524 - 529
  • [23] Detection of inter-turn short-circuit on a Doubly Fed Induction Machine with D-Q axis representation
    Bilal, Habachi
    Heraud, Nicolas
    Sambatra, Eric Jean Roy
    2020 IEEE 61ST ANNUAL INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2020,
  • [24] Inter-turn Short-circuit Analysis in an Induction Machine by Finite Elements Method and Field Tests
    Diaz, D.
    Amaya, M. C.
    Paz, A.
    2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 1757 - 1763
  • [25] Induction machine stator short-circuit fault detection using support vector machine
    Bensaoucha, Saddam
    Brik, Youcef
    Moreau, Sandrine
    Bessedik, Sid Ahmed
    Ameur, Aissa
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 40 (03) : 373 - 389
  • [26] Current and flux correlation analysis for detection, location, and phase identification of stator inter-turn short-circuit fault in doubly-fed induction generator
    Rehman, Attiq Ur
    Chen, Yu
    Zhao, Shouwang
    Huang, Guorui
    Yang, Yan
    Wang, Shuang
    Zhao, Yihan
    Zhao, Yong
    Cheng, Yonghong
    Tanaka, Toshikatsu
    COMPUTERS & ELECTRICAL ENGINEERING, 2024, 117
  • [27] Data-Driven Inter-Turn Short Circuit Fault Detection in Induction Machines
    Xu, Zhao
    Hu, Changhua
    Yang, Feng
    Kuo, Shyh-Hao
    Goh, Chi-Keong
    Gupta, Amit
    Nadarajan, Sivakumar
    IEEE ACCESS, 2017, 5 : 25055 - 25068
  • [28] Stator winding inter-turn insulation fault detection in induction motors by symmetrical components method
    Ballal, M. S.
    Suryawanshi, H. M.
    Mishra, Mahesh K.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2008, 36 (07) : 741 - 753
  • [29] Analysis and Detection of Inter-Turn Short-Circuit Fault Through Extended Self-Commissioning
    Qi, Yuan
    Zafarani, Mohsen
    Akin, Bilal
    Fedigan, Stephen E.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) : 2730 - 2739
  • [30] Modelling and Simulation of Three-Phase Induction Motor to Diagnose the Performance on Inter-Turn Short Circuit Fault in Stator Winding
    Dhamal, Sharad S.
    Bhatkar, M. V.
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 1166 - 1172