Comparative evaluation of Aptima HIV-1 Qualitative RNA assay performance using plasma and serum specimens from persons with established HIV-1 infection

被引:5
作者
Ethridge, Steven F. [1 ]
Wesolowski, Laura G. [1 ]
Nasrullah, Muazzam [1 ]
Kennedy, M. Susan [1 ]
Delaney, Kevin P. [1 ]
Candal, Debra [1 ]
Owen, S. Michele [1 ]
机构
[1] Ctr Dis Control & Prevent, Div HIV AIDS Prevent, Natl Ctr HIV Hepatitis STD & TB Prevent, Atlanta, GA 30333 USA
关键词
HIV testing; Algorithm; United States; Nucleic acid amplification test; NAAT; IMMUNODEFICIENCY-VIRUS RNA; DIAGNOSIS; TESTS; SEROCONVERSION;
D O I
10.1016/j.jcv.2011.09.019
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Blood specimens for HIV testing are frequently collected using serum collection tubes. The Aptima HIV-1 RNA Qualitative test, originally approved for diagnostic use as a supplemental test for use with plasma, is now approved for use with serum, and may be used in new laboratory-based HIV testing algorithms which detect acute and established HIV infections. Objectives: To compare the sensitivity of Aptima using serum and plasma specimens from persons with established HIV infection. Study design: Parallel serum and plasma specimens were collected from 325 persons with established HIV-1 infection who had positive immunoassay (IA) and Western blot (WB) results. Samples with negative Aptima results were considered false-negative and were subjected to repeat testing. Aptima sensitivity for serum and plasma was calculated relative to IA and WB, and compared using the McNemar test. Results: The sensitivity of Aptima using serum (97.23%, 95% confidence interval [CI] 94.81-98.73) was similar to that using plasma (97.54%, 95% [CI] 95.21-98.93) p = 1.00. Five of ten specimens initially false-negative on either serum or plasma were reactive on repeat testing. No specimens initially classified as false-negative on both matrices were reactive on both matrices on repeat testing. Conclusions: In specimens from persons with established infections, Aptima performed with similar sensitivity when used with serum or plasma. Using serum for immunoassay screening and supplemental testing may provide added convenience for laboratories. Published by Elsevier B. V.
引用
收藏
页码:S63 / S66
页数:4
相关论文
共 22 条
[1]  
[Anonymous], 2009, DATA DERIVED UNPUBLI
[2]  
[Anonymous], 2010, C OUTC 2010 HIV DIAG
[3]  
[Anonymous], 2010, ARCH SYST HIV AG AB
[4]  
Association of Public Health Laboratories, 2006, 2006 HIV DIAGN SURV
[5]   Nucleic acid amplification testing for diagnosis of acute HIV infection: has the time come? [J].
Busch, MP ;
Hecht, FA .
AIDS, 2005, 19 (12) :1317-1319
[6]   TIME-COURSE OF DETECTION OF VIRAL AND SEROLOGIC MARKERS PRECEDING HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 SEROCONVERSION - IMPLICATIONS FOR SCREENING OF BLOOD AND TISSUE DONORS [J].
BUSCH, MP ;
LEE, LLL ;
SATTEN, GA ;
HENRARD, DR ;
FARZADEGAN, H ;
NELSON, KE ;
READ, S ;
DODD, RY ;
PETERSEN, LR .
TRANSFUSION, 1995, 35 (02) :91-97
[7]   Performance of the Aptima HIV-1 RNA Qualitative Assay with 16-and 32-Member Specimen Pools [J].
Ethridge, Steven F. ;
Hart, Clyde ;
Hanson, Debra L. ;
Parker, Monica M. ;
Sullivan, Timothy J. ;
Bennett, Berry ;
Stephens, Petrice ;
Hilliard, Joslyn ;
Patel, Pragna .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (09) :3343-3345
[8]   Dynamics of HIV viremia and antibody seroconversion in plasma donors: implications for diagnosis and staging of primary HIV infection [J].
Fiebig, EW ;
Wright, DJ ;
Rawal, BD ;
Garrett, PE ;
Schumacher, RT ;
Peddada, L ;
Heldebrant, C ;
Smith, R ;
Conrad, A ;
Kleinman, SH ;
Busch, MP .
AIDS, 2003, 17 (13) :1871-1879
[9]   Effects of specimen collection, processing, and storage conditions on stability of human immunodeficiency virus type 1 RNA levels in plasma [J].
Ginocchio, CC ;
Wang, XP ;
Kaplan, MH ;
Mulligan, G ;
Witt, D ;
Romano, JW ;
Cronin, M ;
Carroll, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (11) :2886-2893
[10]   Comparison of the Amplicor HIV-1 monitor test and the nucleic acid sequence-based amplification assay for quantitation of human immunodeficiency virus RNA in plasma, serum, and plasma subjected to freeze-thaw cycles [J].
Griffith, BP ;
Rigsby, MO ;
Garner, RB ;
Gordon, MM ;
Chacko, TM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) :3288-3291